Mobile Phone Based Clinical Microscopy for Global Health Applications
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Light microscopy provides a simple, cost-effective, and vital method for the diagnosis and screening of hematologic and infectious diseases. In many regions of the world, however, the required equipment is either unavailable or insufficiently portable, and operators may not possess adequate training to make full use of the images obtained. Counterintuitively, these same regions are often well served by mobile phone networks, suggesting the possibility of leveraging portable, camera-enabled mobile phones for diagnostic imaging and telemedicine. Toward this end we have built a mobile phone-mounted light microscope and demonstrated its potential for clinical use by imaging P. falciparum-infected and sickle red blood cells in brightfield and M. tuberculosis-infected sputum samples in fluorescence with LED excitation. In all cases resolution exceeded that necessary to detect blood cell and microorganism morphology, and with the tuberculosis samples we took further advantage of the digitized images to demonstrate automated bacillus counting via image analysis software. We expect such a telemedicine system for global healthcare via mobile phone -- offering inexpensive brightfield and fluorescence microscopy integrated with automated image analysis -- to provide an important tool for disease diagnosis and screening, particularly in the developing world and rural areas where laboratory facilities are scarce but mobile phone infrastructure is extensive.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Mobile-based light microscopy offers a cheaper and more transportable tool for diagnosing infectious and haematological conditions (70, 73).”
From Assessing the impact of mHealth interventions in low- and middle-income countries – what has been shown to work? (2014) · cites this paper as [70]
The cited source says what the claim attributes to it.
In the citing paper
“Importantly, images can be captured by community health workers (CHWs) and transmitted wirelessly for diagnosis by doctors (45, 70).”
From Assessing the impact of mHealth interventions in low- and middle-income countries – what has been shown to work? (2014) · cites this paper as [70]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
National electrical manufacturers association
(1926) · Journal of the A.I.E.E. · doi:10.1109/jaiee.1926.6537344 · Cited by 860
Fluorescence versus conventional sputum smear microscopy for tuberculosis: a systematic review
Steingart, K. R., Henry, M., Ng, V., Hopewell, P. C., Ramsay, A., Cunningham, J., Urbanczik, R., Perkins, M., Aziz, M. A., & Pai, M. (2006) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(06)70578-3 · Cited by 798
Mobile e-Health: The Unwired Evolution of Telemedicine
Tachakra, S., Wang, X. H., Istepanian, R. S. H., & Song, Y. H. (2003) · Telemedicine Journal and e-Health · doi:10.1089/153056203322502632 · Cited by 252
Steingart, K. R., Henry, M., Laal, S., Hopewell, P. C., Ramsay, A., Menzies, D., Cunningham, J., Weldingh, K., & Pai, M. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040202 · Cited by 238
IEEE Transactions on Information Technology in Biomedicine
(2025) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.4233 · Cited by 230
Design of a telemedicine system using a mobile telephone
Woodward, B., Istepanian, R. S. H., & Richards, C. I. (2001) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.908361 · Cited by 166
Tshilolo, L. M., Kafando, É., Sawadogo, M., COTTON, F. J., Vertongen, F., Ferster, A., & Gulbis, B. (2008) · Public Health · doi:10.1016/j.puhe.2007.12.005 · Cited by 120
Telemedical Wound Care Using a New Generation of Mobile Telephones: A Feasibility Study
Braun, R. P., Vecchietti, J. L., Thomas, L., Prins, C., French, L. E., Gewirtzman, A. J., Saurat, J.-H., & Salomon, D. (2005) · Archives of Dermatology · doi:10.1001/archderm.141.2.254 · Cited by 118
A New Concept for Medical Imaging Centered on Cellular Phone Technology
Granot, Y., Ivorra, A., & Rubinsky, B. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002075 · Cited by 86
Research works printed but not linked: 2
- [15]WHO SEARO/WPRO Workshop on Quality Assurance for Malaria Microscopy 2005 Malaria light microscopy: creating a culture of quality. Kuala Lumpus, Malaysia
- [21]International Union Against Tuberculosis and Lung Disease 2000 Sputum Examination for Tuberculosis by Direct Microscopy in Low Income Countries, Fifth edition. Paris, France
Cited by
Items 301–400 of 761
Myers, D. R., Weiss, A., Rollins, M. R., & Lam, W. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-13076-x · Cited by 26
Self-citationAli, S. M., Naureen, F., Noor, A., Fatima, I. N., Viney, K. A., Ishaq, M., Anjum, N., Rashid, A., Haider, G. R., Khan, M. A., et al. (2018) · BMC Public Health · doi:10.1186/s12889-018-5222-2 · Cited by 26
Huang, W., Luo, S., Yang, D. F., & Zhang, S. (2021) · Journal of Zhejiang University SCIENCE B · doi:10.1631/jzus.b2000388 · Cited by 26
Recent progress in electrochemical sensors for detection and quantification of malaria
Nate, Z., Gill, A. A. S., Chauhan, R., & Karpoormath, R. V. (2022) · Analytical Biochemistry · doi:10.1016/j.ab.2022.114592 · Cited by 25
Kwon, H. N., Park, J., An, Y., Sim, J., & Park, S. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.08.006 · Cited by 25
Pierce, M. C., Weigum, S. E., Jaslove, J. M., Richards-Kortum, R. R., & Tkaczyk, T. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0918-z · Cited by 25
Roche, P. J. R., Filion-Côté, S., Cheung, M. C.-K., Chodavarapu, V. P., & Kirk, A. G. (2011) · Journal of Sensors · doi:10.1155/2011/406425 · Cited by 25
Characterization of the corrosion of iron using a smartphone camera
Igoe, D. P., & Parisi, A. V. (2015) · Instrumentation Science & Technology · doi:10.1080/10739149.2015.1082484 · Cited by 25
Smartphone as a Portable Detector, Analytical Device, or Instrument Interface
Hernández, D. B., Marty, J., & Muñoz, R. (2017) · InTech eBooks · doi:10.5772/intechopen.69678 · Cited by 26
Low-cost cell-phone-based digital lux meter
Sumriddetchkajorn, S., & Somboonkaew, A. (2010) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.870176 · Cited by 25
Mirhosseini, S., Nasiri, A. F., Khatami, F., Mirzaei, A., Aghamir, S. M. K., & Kolahdouz, M. (2024) · Scientific Reports · doi:10.1038/s41598-024-52931-6 · Cited by 24
Wu, T.-F., Yen, T., Han, Y., Chiu, Y., Lin, E. Y.-S., & Lo, Y. (2014) · Lab on a Chip · doi:10.1039/c4lc00257a · Cited by 24
Quantifying Biomolecular Binding Constants using Video Paper Analytical Devices
Miller, B. S., Parolo, C., Turbé, V., Keane, C. E., Gray, E. R., & McKendry, R. A. (2018) · Chemistry - A European Journal · doi:10.1002/chem.201802394 · Cited by 24
3D-Printed Portable Robotic Mobile Microscope for Remote Diagnosis of Global Health Diseases
García-Villena, J., Torres, J. E., Aguilar, C., Lin, L., Bermejo-Peláez, D., Dacal, E., Mousa, A., Ortega, M. D. P., Martínez, Á., Vladimirov, A. P., et al. (2021) · Electronics · doi:10.3390/electronics10192408 · Cited by 24
Smartphone‐Based Android app for Determining UVA Aerosol Optical Depth and Direct Solar Irradiances
Igoe, D. P., Parisi, A. V., & Carter, B. (2013) · Photochemistry and Photobiology · doi:10.1111/php.12185 · Cited by 23
Image Quality Characteristics of Handheld Display Devices for Medical Imaging
Yamazaki, A., Liu, P. X., Cheng, W., & Badano, A. G. (2013) · PLoS ONE · doi:10.1371/journal.pone.0079243 · Cited by 23
Phillips, R. H., Jain, R. N., Browning, Y., Shah, R., Kauffman, P. C., Dinh, D., & Lutz, B. R. (2016) · Lab on a Chip · doi:10.1039/c6lc00738d · Cited by 23
Yang, X., Sun, M., Wang, T., Wong, M. W., & Huang, D. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.11.131 · Cited by 23
Shrestha, R., Duwal, R., Wagle, S., Pokhrel, S., Giri, B., & Neupane, B. B. (2020) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0008560 · Cited by 23
Cadle, B., Rasmus, K. C., Varela, J. A., Leverich, L. S., O’Neill, C. E., Bachtell, R. K., & Cooper, D. (2010) · Substance Abuse Research and Treatment · doi:10.4137/sart.s5025 · Cited by 23
Naraghi, S., Mutsvangwa, T., Goliath, R., Rangaka, M. X., & Douglas, T. S. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.05.009 · Cited by 22
Multiplexed detection of viral infections using rapid in situ RNA analysis on a chip
Shaffer, S. M., Joshi, R. P., Chambers, B. S., Sterken, D., Biaesch, A. G., Gabrieli, D. J., Li, Y., Feemster, K. A., Hensley, S. E., Issadore, D., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00459d · Cited by 22
Bornhorst, J., Nustede, E. J., & Fudickar, S. (2019) · Sensors · doi:10.3390/s19061468 · Cited by 22
Wide-field multi-modal microscopic imaging using smartphone
Rabha, D., Biswas, S., Chamuah, N., Mandal, M., & Nath, P. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106343 · Cited by 22
Ali, Y., & Khan, H. U. (2023) · Computer Networks · doi:10.1016/j.comnet.2023.109605 · Cited by 22
Toward a New Field of Development Engineering: Linking Technology Design to the Demands of the Poor
Nilsson, L. M., Madon, T., & Sastry, S. (2014) · Procedia Engineering · doi:10.1016/j.proeng.2014.07.032 · Cited by 22
Rhoads, D. D., Mathison, B. A., Bishop, H. S., da Silva, A. J., & Pantanowitz, L. (2015) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2015-0116-ra · Cited by 22
Kwon, H., Chan, K. M., & Kool, E. T. (2017) · Organic & Biomolecular Chemistry · doi:10.1039/c6ob02830f · Cited by 22
Dual-mode holographic microscopy imaging platform
Sanz, M., Picazo-Bueno, J. Á., García, J., & Micó, V. (2018) · Lab on a Chip · doi:10.1039/c7lc01304c · Cited by 22
Handheld computing in pathology
Park, S. L., Parwani, A. V., Satyanarayanan, M., & Pantanowitz, L. (2012) · Journal of Pathology Informatics · doi:10.4103/2153-3539.95127 · Cited by 21
Smith, Z. J., Chu, K., & Wachsmann‐Hogiu, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0046030 · Cited by 21
Portable resistive pulse-activated lens-free cell imaging system
Guo, J., Huang, X., Shi, D., Yu, H., Ai, Y., Li, C. M., & Kang, Y. (2014) · RSC Advances · doi:10.1039/c4ra10481a · Cited by 21
Jiang, Z., Ardywibowo, R., Samereh, A., Evans, H. L., Lober, W. B., Chang, X., Qian, X., Wang, Z., & Huang, S. (2019) · Surgical Infections · doi:10.1089/sur.2019.154 · Cited by 21
miniSPIM—A Miniaturized Light-Sheet Microscope
Hedde, P. N. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00607 · Cited by 21
Gupta, R., Reifenberger, R. G., & Kulkarni, G. U. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am4050426 · Cited by 21
Smartphone-Based Biosensors for Bioanalytics
Roda, A., Calabretta, M. M., Calabria, D., Caliceti, C., Cevenini, L., Lopreside, A., & Zangheri, M. (2017) · Comprehensive analytical chemistry · doi:10.1016/bs.coac.2017.05.007 · Cited by 21
Correction of non-uniform angular velocity and sub-pixel jitter in optical scanning
Kowalski, B., Akondi, V., & Dubra, A. (2021) · Optics Express · doi:10.1364/oe.446162 · Cited by 21
Strain measurement based on cooperative operation with different smartphones
Xie, B., Zhang, L., Ding, M., Li, W., & Zhao, X. (2022) · Computer-Aided Civil and Infrastructure Engineering · doi:10.1111/mice.12919 · Cited by 20
Nuñez, V., Upadhyayula, S., Millare, B., Larsen, J. M., Hadian, A., Shin, S., Vandrangi, P., Gupta, S., Xu, H. X., Lin, A., et al. (2013) · Analytical Chemistry · doi:10.1021/ac400200x · Cited by 20
Smartphone microendoscopy for high resolution fluorescence imaging
Hong, X., Nagarajan, V. K., Mugler, D. H., & Yu, B. (2016) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545816500462 · Cited by 20
A Paper Based Milli-Cantilever Sensor for Detecting Hydrocarbon Gases via Smartphone Camera
Qin, X., Wu, T., Zhu, Y., Shan, X., Liu, C., & Tao, N. J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01240 · Cited by 20
Development and characterization of portable smartphone‐based imaging device
Banik, S., Mahato, K. K., Antonini, A., & Mazumder, N. (2020) · Microscopy Research and Technique · doi:10.1002/jemt.23525 · Cited by 20
Wincott, M. B., Jefferson, A., Dobbie, I. M., Booth, M. J., Davis, I., & Parton, R. M. (2021) · Wellcome Open Research · doi:10.12688/wellcomeopenres.16536.2 · Cited by 20
Adapting collaborative radiological practice to low-resource environments
Kolko, B. E., Hope, A., Brunette, W., Saville, K., Gerard, W., Kawooya, M. G., & Nathan, R. (2012) · ACM Conference on Computer Supported Cooperative Work (CSCW) · doi:10.1145/2145204.2145223 · Cited by 20
A novel camera phone-based platform for quantitative fluorescence sensing
O'Driscoll, S., MacCraith, B. D., & Burke, C. S. (2013) · Analytical Methods · doi:10.1039/c3ay40116b · Cited by 20
Telemedicine, eHealth and Remote Care Systems
Wen, C. L. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804591-6.00009-4 · Cited by 21
Mercado, C. L., Welling, J. D., Oliva, M. S., Li, J., Gurung, R., Ruit, S., Tabin, G., Chang, D., & Myung, D. J. (2017) · Journal of Mobile Technology in Medicine · doi:10.7309/jmtm.6.3.6 · Cited by 20
Test and Treat: A New Standard for Smear-Positive Tuberculosis
Davis, J. L., Dowdy, D. W., den Boon, S., Walter, N. D., Katamba, A., & Cattamanchi, A. (2012) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/qai.0b013e3182614bc5 · Cited by 20
Beyond Disease, How Biomedical Engineering Can Improve Global Health
LeDuc, P. R., Agaba, M. K., Cheng, C., Gracio, J. J. D. A., Guzmán, A. M., & Middelberg, A. P. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3009067 · Cited by 20
Mobile device-based digital microscopy for education, healthcare, and agriculture
Sumriddetchkajorn, S., Somboonkaew, A., & Chanhorm, S. (2012) · International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON) · doi:10.1109/ecticon.2012.6254186 · Cited by 20
Correction: A Handheld Point-of-Care Genomic Diagnostic System
Myers, F. B., Henrikson, R. H., Bone, J. M., & Lee, L. P. (2013) · PLoS ONE · doi:10.1371/annotation/902dc1bb-9ed7-4e91-a550-0f0a87ce17ba · Cited by 20
Rabha, D., Rather, M. A., Mandal, M., & Nath, P. (2021) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2021.106931 · Cited by 19
Shukla, S., Sah, A. N., Hatiboruah, D., Ahirwar, S., Nath, P., & Pradhan, A. (2022) · Scientific Reports · doi:10.1038/s41598-022-15007-x · Cited by 19
Huang, B., Kang, L., Tsang, V. T. C., Lo, C. T. K., & Wong, T. T. W. (2024) · Biomedical Optics Express · doi:10.1364/boe.511384 · Cited by 19
Enhanced light collection in fluorescence microscopy using self-assembled micro-reflectors
Göröcs, Z. S., McLeod, E. J., & Özcan, A. (2015) · Scientific Reports · doi:10.1038/srep10999 · Cited by 19
Low-cost optical manipulation using hanging droplets of PDMS
McDonald, C., & McGloin, D. (2015) · RSC Advances · doi:10.1039/c5ra11431d · Cited by 19
Lundin, J. E., & Dumont, G. A. (2017) · Global Health Action · doi:10.1080/16549716.2017.1344046 · Cited by 19
Wang, R., Zhao, Q., Quinn, J., Yang, L., Zhu, Y., Huang, F., Guo, C., Wang, T., Song, P., Murphy, M., et al. (2026) · eLight · doi:10.1186/s43593-025-00103-y · Cited by 20
Amarit, R., Kopwitthaya, A., Pongsoon, P., Jarujareet, U., Chaitavon, K., Porntheeraphat, S., Sumriddetchkajorn, S., & Koanantakool, T. (2016) · PLoS ONE · doi:10.1371/journal.pone.0146414 · Cited by 18
Wave optics of imaging with contact ball lenses
Maslov, A. V., Jin, B., & Astratov, V. N. (2023) · Scientific Reports · doi:10.1038/s41598-023-32826-8 · Cited by 18
Direct Reading of Bona Fide Barcode Assays for Diagnostics with Smartphone Apps
Wong, J. X. H., Li, X., Liu, F. S. F., & Yu, H. (2015) · Scientific Reports · doi:10.1038/srep11727 · Cited by 18
Kaur, T., Dahiya, S., SATIJA, S. H., Nawal, S., Kshetrimayum, N., Ningthoujam, J. S., CHAHAL, A. K., & RAO, A. (2020) · Journal of Microscopy · doi:10.1111/jmi.12896 · Cited by 18
Cell Phones as Mobile Computing Devices
Wong, K. Y. (2010) · IT Professional · doi:10.1109/mitp.2010.46 · Cited by 18
Colorimetric water quality sensing with mobile smart phones
Schaefer, S. (2014) · cIRcle (University of British Columbia) · doi:10.14288/1.0074338 · Cited by 18
Cell Phones in Telehealth and Otolaryngology
Kenyon, J., Poropatich, R. K., & Holtel, M. R. (2011) · Otolaryngologic Clinics of North America · doi:10.1016/j.otc.2011.08.013 · Cited by 18
Opto-Fluidics Based Microscopy and Flow Cytometry on a Cell Phone for Blood Analysis
Zhu, H., & Özcan, A. (2014) · Methods in molecular biology · doi:10.1007/978-1-4939-2172-0_12 · Cited by 17
Parasite Detection in Thick Blood Smears Based on Customized Faster-RCNN on Smartphones
Yang, F., Yu, H., Silamut, K., Maude, R. J., Jaeger, S., & Antani, S. (2019) · IEEE Applied Imagery Pattern Recognition Workshop · doi:10.1109/aipr47015.2019.9174565 · Cited by 17
Kim, K.-S., & Lee, W. G. (2022) · Small Methods · doi:10.1002/smtd.202200979 · Cited by 17
A semi-automated, field-portable microscopy platform for clinical diagnostic applications
Jagannadh, V. K., Srinivasan, R., & Gorthi, S. S. (2015) · AIP Advances · doi:10.1063/1.4915133 · Cited by 17
Auguste, L. J., & Palsana, D. (2015) · BMJ Innovations · doi:10.1136/bmjinnov-2015-000040 · Cited by 17
New Technologies for Glaucoma Detection
Uña, I. R., & Azuara‐Blanco, A. (2018) · Asia-Pacific Journal of Ophthalmology · doi:10.22608/apo.2018349 · Cited by 17
Exploiting heat shock protein expression to develop a non-invasive diagnostic tool for breast cancer
Crouch, B. T., Gallagher, J., Wang, R., Duer, J. E., Hall, A. H. S., Soo, M. S., Hughes, P. F., Haystead, T., & Ramanujam, N. (2019) · Scientific Reports · doi:10.1038/s41598-019-40252-y · Cited by 17
Smartphone-Based Point-of-Care Technologies for Mobile Healthcare
Vashist, S. K., & Luong, J. H. T. (2019) · Springer eBooks · doi:10.1007/978-3-030-11416-9_2 · Cited by 17
An integrated centrifugal microfluidic strategy for point-of-care complete blood counting
Khodadadi, R., Eghbal, M., Ofoghi, H., Balaei, A., Tamayol, A., Abrinia, K., Sanati‐Nezhad, A., & Samandari, M. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115789 · Cited by 16
Quantitative, high-sensitivity measurement of liquid analytes using a smartphone compass
Ferris, M. S., & Zabow, G. (2024) · Nature Communications · doi:10.1038/s41467-024-47073-2 · Cited by 16
Çelik, H., Caf, B. B., & Çebi, G. (2025) · Chemical Papers · doi:10.1007/s11696-025-04319-7 · Cited by 16
Udhani, R., Kothari, C. S., & Sarvaiya, J. (2023) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2023.2169823 · Cited by 18
Su, K., Zou, Q., Hu, N., & Wang, P. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7320181 · Cited by 16
Vashist, S. K., & Luong, J. H. T. (2019) · Springer eBooks · doi:10.1007/978-3-030-11416-9_1 · Cited by 16
Large field-of-view phase and fluorescence mesoscope with microscopic resolution
de Kernier, I. L. C., Ali‐Cherif, A., Rongeat, N., Cioni, O., Morales, S., Savatier, J., Monneret, S., & Blandin, P. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.3.036501 · Cited by 16
Kuroda, A., Alexandrov, M., Nishimura, T., & Ishida, T. (2016) · Biotechnology Journal · doi:10.1002/biot.201500438 · Cited by 16
Biomedical sensor technologies on the platform of mobile phones
Liu, L., & Liu, J. (2011) · Frontiers of Mechanical Engineering · doi:10.1007/s11465-011-0216-0 · Cited by 15
Embedded Adaptive Optics for Ubiquitous Lab-on-a-Chip Readout on Intact Cell Phones
Preechaburana, P., Suska, A., & Filippini, D. (2012) · Sensors · doi:10.3390/s120708586 · Cited by 15
Najafiaghdam, H., Papageorgiou, E. P., Torquato, N. A., Tian, B., Cohen, B. E., & Anwar, M. (2019) · Theranostics · doi:10.7150/thno.37672 · Cited by 15
Skin chromophore mapping by smartphone RGB camera under spectral band and spectral line illumination
Kuzmina, I., Oshina, I., Dambite, L., Lukinsone, V., Maslobojeva, A., Berzina, A., & Spīgulis, J. (2022) · Journal of Biomedical Optics · doi:10.1117/1.jbo.27.2.026004 · Cited by 15
SmartOCT: smartphone-integrated optical coherence tomography
Malone, J. D., Hussain, I., & Bowden, A. K. (2023) · Biomedical Optics Express · doi:10.1364/boe.492439 · Cited by 15
Overview of CMOS image sensor use in molecular diagnostics
Devadhasan, J. P., Yoo, I. S., & Kim, S. (2015) · Current Applied Physics · doi:10.1016/j.cap.2015.01.009 · Cited by 15
Luz, S. F., Masoodian, M., & Cesário, M. (2013) · Behaviour and Information Technology · doi:10.1080/0144929x.2013.853836 · Cited by 15
Teles, F., & Fonseca, L. P. (2014) · Methods in molecular biology · doi:10.1007/978-1-4939-2004-4_20 · Cited by 15
Shah, M. I., Mishra, S., Sarkar, M. S., & Sudarshan, S. K. (2016) · International Conference on Parallel, Distributed and Grid Computing (PDGC) · doi:10.1109/pdgc.2016.7913161 · Cited by 15
Chen, G., Chai, H. H., Yu, L. D., & Fang, C. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.004604 · Cited by 15
Optofluidic lenses for 2D and 3D imaging
Huang, H., & Zhao, Y. (2019) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ab1999 · Cited by 15
Smartphone based mobile microscopy for diagnostics
Pfeil, J., Dangelat, L. N., Frohme, M., & Schulze, K. (2019) · Journal of Cellular Biotechnology · doi:10.3233/jcb-180010 · Cited by 15
van Heerden, A. C. (2014) · University of the Witwatersrand, Johannesburg Institutional Repository on DSpace (University of the Witwatersrand, Johannesburg) · Cited by 15
Kim, Y., Oh, J., Choi, S., Jung, A., Lee, J., Lee, Y. S., & Kim, J. K. (2021) · JMIR mhealth and uhealth · doi:10.2196/25816 · Cited by 14
An introduction to microfluidics and their applications
Verma, N., Prajapati, P., Singh, V., & Pandya, A. (2022) · Progress in molecular biology and translational science · doi:10.1016/bs.pmbts.2021.07.006 · Cited by 14
Mobile phone‐based UV fluorescence microscopy for the identification of fungal pathogens
Goenka, C., Lewis, W., Chevres‐Fernández, L. R., Ortega‐Martínez, A., Ibarra‐Silva, E., Williams, M., & Franco, W. (2018) · Lasers in Surgery and Medicine · doi:10.1002/lsm.23012 · Cited by 14
Damodaran, K., Crestani, M., Jokhun, D. S., & Shivashankar, G. V. (2019) · PLoS ONE · doi:10.1371/journal.pone.0218757 · Cited by 14
Design of a Cell Phone Lens-Based Miniature Microscope with Configurable Magnification Ratio
Wan, X., & Tao, X. (2021) · Applied Sciences · doi:10.3390/app11083392 · Cited by 14
Development, information and social connectivity in Côte d’Ivoire
Andris, C., & Bettencourt, L. M. A. (2014) · Infrastructure Complexity · doi:10.1186/s40551-014-0001-4 · Cited by 14
Metadata
- Authors
- Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A.
- Affiliations
- University of California, San Francisco (US)
- University of California, Berkeley (US)
- Corresponding author
- Fletcher, Daniel A.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2009-07-22
- Volume
- 4
- Issue
- 7
- Pages
- e6320
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC2709430
- OpenAlex
- W2104431608
- Cited by
- 694
- References
- 20
- Citations by year
- 2026: 14 · 2025: 14 · 2024: 18 · 2023: 27 · 2022: 27 · 2021: 46 · 2020: 42 · 2019: 48 · 2018: 66 · 2017: 52 · 2016: 53 · 2015: 59 · 2014: 71 · 2013: 46 · 2012: 52
- FWCI
- 40.78
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Science Foundation
- Microsoft Research
- University of California Berkeley
- Blum Center for Developing Economies, University of California Berkeley
- Center for Information Technology Research in the Interest of Society
- University of California, San Francisco
- National Defense Science and Engineering Graduate
- Center for Information Technology
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Digital Imaging for Blood Diseases
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- optical microscopy, telemedicine, malaria diagnosis, Plasmodium falciparum, sickle red blood cells, tuberculosis, Mycobacterium tuberculosis, sputum smear microscopy, fluorescence microscopy, image analysis, resource-limited settings
- MeSH terms
- Anemia, Sickle Cell, Animals, Equipment Design, Fluorescence, Humans, Microscopy, Mycobacterium tuberculosis, Plasmodium falciparum, Tuberculosis, Global Health, Cell Phone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.