Mobile Phone Based Clinical Microscopy for Global Health Applications
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Light microscopy provides a simple, cost-effective, and vital method for the diagnosis and screening of hematologic and infectious diseases. In many regions of the world, however, the required equipment is either unavailable or insufficiently portable, and operators may not possess adequate training to make full use of the images obtained. Counterintuitively, these same regions are often well served by mobile phone networks, suggesting the possibility of leveraging portable, camera-enabled mobile phones for diagnostic imaging and telemedicine. Toward this end we have built a mobile phone-mounted light microscope and demonstrated its potential for clinical use by imaging P. falciparum-infected and sickle red blood cells in brightfield and M. tuberculosis-infected sputum samples in fluorescence with LED excitation. In all cases resolution exceeded that necessary to detect blood cell and microorganism morphology, and with the tuberculosis samples we took further advantage of the digitized images to demonstrate automated bacillus counting via image analysis software. We expect such a telemedicine system for global healthcare via mobile phone -- offering inexpensive brightfield and fluorescence microscopy integrated with automated image analysis -- to provide an important tool for disease diagnosis and screening, particularly in the developing world and rural areas where laboratory facilities are scarce but mobile phone infrastructure is extensive.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Mobile-based light microscopy offers a cheaper and more transportable tool for diagnosing infectious and haematological conditions (70, 73).”
From Assessing the impact of mHealth interventions in low- and middle-income countries – what has been shown to work? (2014) · cites this paper as [70]
The cited source says what the claim attributes to it.
In the citing paper
“Importantly, images can be captured by community health workers (CHWs) and transmitted wirelessly for diagnosis by doctors (45, 70).”
From Assessing the impact of mHealth interventions in low- and middle-income countries – what has been shown to work? (2014) · cites this paper as [70]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
National electrical manufacturers association
(1926) · Journal of the A.I.E.E. · doi:10.1109/jaiee.1926.6537344 · Cited by 860
Fluorescence versus conventional sputum smear microscopy for tuberculosis: a systematic review
Steingart, K. R., Henry, M., Ng, V., Hopewell, P. C., Ramsay, A., Cunningham, J., Urbanczik, R., Perkins, M., Aziz, M. A., & Pai, M. (2006) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(06)70578-3 · Cited by 798
Mobile e-Health: The Unwired Evolution of Telemedicine
Tachakra, S., Wang, X. H., Istepanian, R. S. H., & Song, Y. H. (2003) · Telemedicine Journal and e-Health · doi:10.1089/153056203322502632 · Cited by 252
Steingart, K. R., Henry, M., Laal, S., Hopewell, P. C., Ramsay, A., Menzies, D., Cunningham, J., Weldingh, K., & Pai, M. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040202 · Cited by 238
IEEE Transactions on Information Technology in Biomedicine
(2025) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.4233 · Cited by 230
Design of a telemedicine system using a mobile telephone
Woodward, B., Istepanian, R. S. H., & Richards, C. I. (2001) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.908361 · Cited by 166
Tshilolo, L. M., Kafando, É., Sawadogo, M., COTTON, F. J., Vertongen, F., Ferster, A., & Gulbis, B. (2008) · Public Health · doi:10.1016/j.puhe.2007.12.005 · Cited by 120
Telemedical Wound Care Using a New Generation of Mobile Telephones: A Feasibility Study
Braun, R. P., Vecchietti, J. L., Thomas, L., Prins, C., French, L. E., Gewirtzman, A. J., Saurat, J.-H., & Salomon, D. (2005) · Archives of Dermatology · doi:10.1001/archderm.141.2.254 · Cited by 118
A New Concept for Medical Imaging Centered on Cellular Phone Technology
Granot, Y., Ivorra, A., & Rubinsky, B. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002075 · Cited by 86
Research works printed but not linked: 2
- [15]WHO SEARO/WPRO Workshop on Quality Assurance for Malaria Microscopy 2005 Malaria light microscopy: creating a culture of quality. Kuala Lumpus, Malaysia
- [21]International Union Against Tuberculosis and Lung Disease 2000 Sputum Examination for Tuberculosis by Direct Microscopy in Low Income Countries, Fifth edition. Paris, France
Cited by
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Miniaturized integration of a fluorescence microscope
Ghosh, K. K., Burns, L. D., Cocker, E. D., Nimmerjahn, A., Ziv, Y., Gamal, A. E., & Schnitzer, M. J. (2011) · Nature Methods · doi:10.1038/nmeth.1694 · Cited by 1,120
Amplification-free detection of SARS-CoV-2 with CRISPR-Cas13a and mobile phone microscopy
Fozouni, P., Son, S., Díaz de León Derby, M., Knott, G. J., Gray, C. N., D’Ambrosio, M. V., Zhao, C., Switz, N. A., Kumar, G. R., Stephens, S. I., et al. (2021) · Cell · doi:10.1016/j.cell.2020.12.001 · Cited by 1,047
Self-citationEmerging Technologies for Next-Generation Point-of-Care Testing
Vashist, S. K., Luppa, P. B., Yeo, L. Y., Ozcan, A., & Luong, J. H. T. (2015) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.001 · Cited by 705
The Smartphone in Medicine: A Review of Current and Potential Use Among Physicians and Students
Ozdalga, E., Ozdalga, A., & Ahuja, N. (2012) · Journal of Medical Internet Research · doi:10.2196/jmir.1994 · Cited by 654
Biosensors and bioelectronics on smartphone for portable biochemical detection
Zhang, D., & Liu, Q. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.037 · Cited by 647
Image analysis and machine learning for detecting malaria
Poostchi, M., Silamut, K., Maude, R. J., Jaeger, S., & Thoma, G. (2018) · Translational Research · doi:10.1016/j.trsl.2017.12.004 · Cited by 559
Smartphone-based biosensors: A critical review and perspectives
Roda, A., Michelini, E., Zangheri, M., Di Fusco, M., Calabria, D., & Simoni, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.019 · Cited by 520
Lensfree microscopy on a cellphone
Tseng, D., Mudanyali, O., Oztoprak, C., Isikman, S. O., Sencan, I., Yaglidere, O., & Ozcan, A. (2010) · Lab on a Chip · doi:10.1039/c003477k · Cited by 480
Biosensor technology: recent advances in threat agent detection and medicine
Kirsch, J., Siltanen, C., Zhou, Q., Revzin, A., & Simonian, A. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60141b · Cited by 462
Fluorescent Imaging of Single Nanoparticles and Viruses on a Smart Phone
Wei, Q., Qi, H., Luo, W., Tseng, D., Ki, S. J., Wan, Z., Göröcs, Z., Bentolila, L. A., Wu, T.-T., Sun, R., et al. (2013) · ACS Nano · doi:10.1021/nn4037706 · Cited by 452
Optofluidic Fluorescent Imaging Cytometry on a Cell Phone
Zhu, H., Mavandadi, S., Coskun, A. F., Yaglidere, O., & Ozcan, A. (2011) · Analytical Chemistry · doi:10.1021/ac201587a · Cited by 390
Foldscope: Origami-Based Paper Microscope
Cybulski, J. S., Clements, J., & Prakash, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0098781 · Cited by 388
Hall, C. S., Fottrell, E., Wilkinson, S., & Byass, P. (2014) · Global Health Action · doi:10.3402/gha.v7.25606 · Cited by 384
Point-of-care microfluidic devices for pathogen detection
Nasseri, B., Soleimani, N., Rabiee, N., Kalbasi, A., Karimi, M., & Hamblin, M. R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.050 · Cited by 382
Mobile phones democratize and cultivate next-generation imaging, diagnostics and measurement tools
Ozcan, A. (2014) · Lab Chip · doi:10.1039/c4lc00010b · Cited by 364
Optical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc40864c · Cited by 364
Berg, B., Cortazar, B., Tseng, D., Ozkan, H., Feng, S., Wei, Q., Chan, R. Y.-L., Burbano, J., Farooqui, Q., Lewinski, M., et al. (2015) · ACS Nano · doi:10.1021/acsnano.5b03203 · Cited by 362
Nano/Microfluidics for diagnosis of infectious diseases in developing countries
Lee, W. G., Kim, Y.-G., Chung, B. G., Demirci, U., & Khademhosseini, A. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.016 · Cited by 357
Microfluidics for medical diagnostics and biosensors
Rivet, C., Lee, H., Hirsch, A., Hamilton, S., & Lu, H. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.08.015 · Cited by 356
Handheld high-throughput plasmonic biosensor using computational on-chip imaging
Cetin, A. E., Coskun, A. F., Galarreta, B. C., Huang, M., Herman, D., Ozcan, A., & Altug, H. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.3 · Cited by 354
Ozcan, A., & McLeod, E. (2016) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-092515-010849 · Cited by 352
Recent developments in computer vision-based analytical chemistry: A tutorial review
Capitán-Vallvey, L. F., López-Ruiz, N., Martínez-Olmos, A., Erenas, M. M., & Palma, A. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.10.009 · Cited by 341
Cell-Phone-Based Platform for Biomedical Device Development and Education Applications
Smith, Z. J., Chu, K., Espenson, A. R., Rahimzadeh, M., Gryshuk, A., Molinaro, M., Dwyre, D. M., Lane, S., Matthews, D., & Wachsmann-Hogiu, S. (2011) · PLoS ONE · doi:10.1371/journal.pone.0017150 · Cited by 339
Cost-effective and compact wide-field fluorescent imaging on a cell-phone
Zhu, H., Yaglidere, O., Su, T.-W., Tseng, D., & Ozcan, A. (2011) · Lab Chip · doi:10.1039/c0lc00358a · Cited by 330
Bibliometric analysis of worldwide scientific literature in mobile - health: 2006–2016
Sweileh, W. M., Al-Jabi, S. W., AbuTaha, A. S., Zyoud, S. H., Anayah, F. M. A., & Sawalha, A. F. (2017) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-017-0476-7 · Cited by 319
Label-free biodetection using a smartphone
Gallegos, D., Long, K. D., Yu, H., Clark, P. P., Lin, Y., George, S., Nath, P., & Cunningham, B. T. (2013) · Lab on a Chip · doi:10.1039/c3lc40991k · Cited by 312
Cellphone-based devices for bioanalytical sciences
Vashist, S. K., Mudanyali, O., Schneider, E. M., Zengerle, R., & Ozcan, A. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7473-1 · Cited by 305
Smartphone-based analytical biosensors
Huang, X., Xu, D., Chen, J., Liu, J., Li, Y., Song, J., Ma, X., & Guo, J. (2018) · The Analyst · doi:10.1039/c8an01269e · Cited by 305
A smartphone-based diagnostic platform for rapid detection of Zika, chikungunya, and dengue viruses
Priye, A., Bird, S. W., Light, Y. K., Ball, C. S., Negrete, O. A., & Meagher, R. J. (2017) · Scientific Reports · doi:10.1038/srep44778 · Cited by 300
Holographic pixel super-resolution in portable lensless on-chip microscopy using a fiber-optic array
Bishara, W., Sikora, U., Mudanyali, O., Su, T.-W., Yaglidere, O., Luckhart, S., & Ozcan, A. (2011) · Lab on a Chip · doi:10.1039/c0lc00684j · Cited by 288
A smartphone algorithm with inter-phone repeatability for the analysis of colorimetric tests
Yetisen, A. K., Martinez-Hurtado, J. L., Garcia-Melendrez, A., da Cruz Vasconcellos, F., & Lowe, C. R. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.01.077 · Cited by 285
“The use of smartphone cameras as been suggested for diagnostic applications in dermatology [3], icroscopy [4–6], ophthalmology [7], chemical analyses [8,9] and aper-based microfluidic devices [10–12].”
MethodQuantum dot enabled detection of Escherichia coli using a cell-phone
Zhu, H., Sikora, U., & Ozcan, A. (2012) · The Analyst · doi:10.1039/c2an35071h · Cited by 277
Cost-effective and rapid blood analysis on a cell-phone
Zhu, H., Sencan, I., Wong, J., Dimitrov, S., Tseng, D., Nagashima, K., & Ozcan, A. (2013) · Lab on a Chip · doi:10.1039/c3lc41408f · Cited by 274
Mobile phone-based biosensing: An emerging “diagnostic and communication” technology
Quesada-González, D., & Merkoçi, A. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.10.062 · Cited by 272
Smartphone app for non-invasive detection of anemia using only patient-sourced photos
Mannino, R. G., Myers, D. R., Tyburski, E. A., Caruso, C., Boudreaux, J., Leong, T., Clifford, G. D., & Lam, W. A. (2018) · Nature Communications · doi:10.1038/s41467-018-07262-2 · Cited by 272
Self-citationComputational pathology: Challenges and promises for tissue analysis
Fuchs, T. J., & Buhmann, J. M. (2011) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2011.02.006 · Cited by 265
Rapid electrochemical detection on a mobile phone
Lillehoj, P. B., Huang, M.-C., Truong, N., & Ho, C.-M. (2013) · Lab on a Chip · doi:10.1039/c3lc50306b · Cited by 259
Wang, S., Zhao, X., Khimji, I., Akbas, R., Qiu, W., Edwards, D., Cramer, D. W., Ye, B., & Demirci, U. (2011) · Lab on a Chip · doi:10.1039/c1lc20479c · Cited by 254
Vashist, S., Schneider, E., & Luong, J. (2014) · Diagnostics · doi:10.3390/diagnostics4030104 · Cited by 244
Surface Plasmon Resonance Chemical Sensing on Cell Phones
Preechaburana, P., Gonzalez, M. C., Suska, A., & Filippini, D. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201206804 · Cited by 238
Point-of-care quantification of blood-borne filarial parasites with a mobile phone microscope
D’Ambrosio, M. V., Bakalar, M., Bennuru, S., Reber, C., Skandarajah, A., Nilsson, L., Switz, N., Kamgno, J., Pion, S., Boussinesq, M., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa3480 · Cited by 237
Self-citationMobile health use in low- and high-income countries: an overview of the peer-reviewed literature
Bastawrous, A., & Armstrong, M. J. (2013) · Journal of the Royal Society of Medicine · doi:10.1177/0141076812472620 · Cited by 236
Mobile healthcare applications: system design review, critical issues and challenges
Baig, M. M., GholamHosseini, H., & Connolly, M. J. (2015) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/s13246-014-0315-4 · Cited by 234
Vashist, S. K., van Oordt, T., Schneider, E. M., Zengerle, R., von Stetten, F., & Luong, J. H. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.08.027 · Cited by 227
A smartphone based surface plasmon resonance imaging (SPRi) platform for on-site biodetection
Guner, H., Ozgur, E., Kokturk, G., Celik, M., Esen, E., Topal, A. E., Ayas, S., Uludag, Y., Elbuken, C., & Dana, A. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.08.061 · Cited by 226
Greenbaum, A., & Ozcan, A. (2012) · Optics Express · doi:10.1364/oe.20.003129 · Cited by 225
Low-Cost Mobile Phone Microscopy with a Reversed Mobile Phone Camera Lens
Switz, N. A., D'Ambrosio, M. V., & Fletcher, D. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0095330 · Cited by 223
Self-citationTools for water quality monitoring and mapping using paper-based sensors and cell phones
Sicard, C., Glen, C., Aubie, B., Wallace, D., Jahanshahi-Anbuhi, S., Pennings, K., Daigger, G. T., Pelton, R., Brennan, J. D., & Filipe, C. D. M. (2015) · Water Research · doi:10.1016/j.watres.2014.12.005 · Cited by 216
Advances in Smartphone-Based Point-of-Care Diagnostics
Xu, X., Akay, A., Wei, H., Wang, S., Pingguan-Murphy, B., Erlandsson, B.-E., Li, X., Lee, W., Hu, J., Wang, L., et al. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2378776 · Cited by 213
Albumin testing in urine using a smart-phone
Coskun, A. F., Nagi, R., Sadeghi, K., Phillips, S., & Ozcan, A. (2013) · Lab on a Chip · doi:10.1039/c3lc50785h · Cited by 208
Malaria Diagnosis Using a Mobile Phone Polarized Microscope
Pirnstill, C. W., & Coté, G. L. (2015) · Scientific Reports · doi:10.1038/srep13368 · Cited by 207
Smartphone‐based clinical diagnostics: towards democratization of evidence‐based health care
Hernández‐Neuta, I., Neumann, F., Brightmeyer, J., Ba Tis, T., Madaboosi, N., Wei, Q., Ozcan, A., & Nilsson, M. (2019) · Journal of Internal Medicine · doi:10.1111/joim.12820 · Cited by 205
Yang, K., Peretz-Soroka, H., Liu, Y., & Lin, F. (2016) · Lab on a Chip · doi:10.1039/c5lc01524c · Cited by 198
Quantitative Imaging with a Mobile Phone Microscope
Skandarajah, A., Reber, C. D., Switz, N. A., & Fletcher, D. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0096906 · Cited by 196
Self-citationMobile Phone-Based Microscopy, Sensing, and Diagnostics
Contreras-Naranjo, J. C., Wei, Q., & Ozcan, A. (2016) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2015.2478657 · Cited by 196
Microfluidic platform towards point-of-care diagnostics in infectious diseases
Su, W., Gao, X., Jiang, L., & Qin, J. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.12.041 · Cited by 196
Kouzehkanan, Z. M., Saghari, S., Tavakoli, S., Rostami, P., Abaszadeh, M., Mirzadeh, F., Satlsar, E. S., Gheidishahran, M., Gorgi, F., Mohammadi, S., et al. (2022) · Scientific Reports · doi:10.1038/s41598-021-04426-x · Cited by 193
Ming, K., Kim, J., Biondi, M. J., Syed, A., Chen, K., Lam, A., Ostrowski, M., Rebbapragada, A., Feld, J. J., & Chan, W. C. W. (2015) · ACS Nano · doi:10.1021/nn5072792 · Cited by 192
Gene-Z: a device for point of care genetic testing using a smartphone
Stedtfeld, R. D., Tourlousse, D. M., Seyrig, G., Stedtfeld, T. M., Kronlein, M., Price, S., Ahmad, F., Gulari, E., Tiedje, J. M., & Hashsham, S. A. (2012) · Lab on a Chip · doi:10.1039/c2lc21226a · Cited by 187
Mobile applications for the health sector
Miller, R. J., Qiang, C. Z., Yamamichi, M., & Hausman, V. (2012) · Cited by 182
Investigating a smartphone imaging unit for photoplethysmography
Jonathan, E., & Leahy, M. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/11/n01 · Cited by 177
A smartphone-based chip-scale microscope using ambient illumination
Lee, S. A., & Yang, C. (2014) · Lab on a Chip · doi:10.1039/c4lc00523f · Cited by 174
Mengel, M. A., Delrieu, I., Heyerdahl, L. W., & Gessner, B. D. (2014) · Current topics in microbiology and immunology · doi:10.1007/82_2014_369 · Cited by 172
Imaging and Sizing of Single DNA Molecules on a Mobile Phone
Wei, Q., Luo, W., Chiang, S., Kappel, T., Mejia, C., Tseng, D., Chan, R. Y. L., Yan, E., Qi, H., Shabbir, F., et al. (2014) · ACS Nano · doi:10.1021/nn505821y · Cited by 169
Clinical Validation of a Smartphone-Based Adapter for Optic Disc Imaging in Kenya
Bastawrous, A., Giardini, M. E., Bolster, N. M., Peto, T., Shah, N., Livingstone, I. A. T., Weiss, H. A., Hu, S., Rono, H., Kuper, H., et al. (2016) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2015.4625 · Cited by 169
Point-of-care testing: applications of 3D printing
Chan, H. N., Tan, M. J. A., & Wu, H. (2017) · Lab on a Chip · doi:10.1039/c7lc00397h · Cited by 168
Intelligent biosensing strategies for rapid detection in food safety: A review
Zhang, J., Huang, H., Song, G., Huang, K., Luo, Y., Liu, Q., He, X., & Cheng, N. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114003 · Cited by 168
McGonigle, A., Wilkes, T., Pering, T., Willmott, J., Cook, J., Mims, F., & Parisi, A. (2018) · Sensors · doi:10.3390/s18010223 · Cited by 164
Ferreira, M. F. S., Castro-Camus, E., Ottaway, D. J., Higuera, J. M. L., Feng, X., Jin, W., Jeong, Y., Picqué, N., Tong, L., Reinhard, B. M., et al. (2017) · Journal of Optics · doi:10.1088/2040-8986/aa7419 · Cited by 165
Deep Learning Enhanced Mobile-Phone Microscopy
Rivenson, Y., Ceylan Koydemir, H., Wang, H., Wei, Z., Ren, Z., Günaydın, H., Zhang, Y., Göröcs, Z., Liang, K., Tseng, D., et al. (2018) · ACS Photonics · doi:10.1021/acsphotonics.8b00146 · Cited by 162
Recent Progress in Optical Biosensors Based on Smartphone Platforms
Geng, Z., Zhang, X., Fan, Z., Lv, X., Su, Y., & Chen, H. (2017) · Sensors · doi:10.3390/s17112449 · Cited by 156
Tools for the Microbiome: Nano and Beyond
Biteen, J. S., Blainey, P. C., Cardon, Z. G., Chun, M., Church, G. M., Dorrestein, P. C., Fraser, S. E., Gilbert, J. A., Jansson, J. K., Knight, R., et al. (2016) · ACS Nano · doi:10.1021/acsnano.5b07826 · Cited by 144
Point of care in your pocket: a research agenda for the field of m-health
van Heerden, A., Tomlinson, M., & Swartz, L. (2012) · Bulletin of the World Health Organization · doi:10.2471/blt.11.099788 · Cited by 158
Swendeman, D., & Rotheram-Borus, M. J. (2010) · Current Opinion in Psychiatry · doi:10.1097/yco.0b013e328336656a · Cited by 157
Deep-Learning-Based Image Reconstruction and Enhancement in Optical Microscopy
Haan, K. D., Rivenson, Y., Wu, Y., & Özcan, A. (2019) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2949575 · Cited by 158
Novel and Improved Technologies for Tuberculosis Diagnosis: Progress and Challenges
Pai, M., Minion, J., Sohn, H., Zwerling, A. A., & Perkins, M. D. (2009) · Clinics in Chest Medicine · doi:10.1016/j.ccm.2009.08.016 · Cited by 153
Greenbaum, A., Sikora, U., & Özcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc21072j · Cited by 153
A one-piece 3D printed flexure translation stage for open-source microscopy
Sharkey, J. P., Foo, D. C. W., Kabla, A., Baumberg, J. J., & Bowman, R. W. (2016) · Review of Scientific Instruments · doi:10.1063/1.4941068 · Cited by 150
Optical imaging techniques in microfluidics and their applications
Wu, J., Zheng, G., & Lee, L. M. (2012) · Lab on a Chip · doi:10.1039/c2lc40517b · Cited by 150
Evolution and current status of mhealth research: a systematic review
Ali, E. E., Chew, L., & Yap, K. Y.-L. (2016) · BMJ Innovations · doi:10.1136/bmjinnov-2015-000096 · Cited by 119
Smartphone instrument for portable enzyme- linked immunosorbent assays
Long, K. D., Yu, H., & Cunningham, B. T. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.003792 · Cited by 147
Linder, N., Turkki, R., Walliander, M., Mårtensson, A., Diwan, V. K., Rahtu, E., Pietikäinen, M., Lundin, M., & Lundin, J. E. (2014) · PLoS ONE · doi:10.1371/journal.pone.0104855 · Cited by 147
Sub-pixel resolving optofluidic microscope for on-chip cell imaging
Zheng, G., Lee, S. A., Yang, S., & Yang, C. (2010) · Lab on a Chip · doi:10.1039/c0lc00213e · Cited by 145
A smartphone-based optical platform for colorimetric analysis of microfluidic device
Kim, S. C., Jalal, U. M., Im, S. B., Ko, S., & Shim, J. S. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.07.159 · Cited by 145
Asiimwe, C., Gelvin, D., Lee, E., Amor, Y. B., Quinto, E., Katureebe, C., Sundaram, L., Bell, D., & Berg, M. (2011) · The American Society of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2011.10-0528 · Cited by 123
Point‐of‐Care Smartphone‐based Electrochemical Biosensing
Sun, A. C., & Hall, D. A. (2019) · Electroanalysis · doi:10.1002/elan.201800474 · Cited by 131
Point-of-care assays for tuberculosis: Role of nanotechnology/microfluidics
Wang, S., İnci, F., Libero, G. D., Singhal, A., & Demirci, U. (2013) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.01.006 · Cited by 141
Distributed Medical Image Analysis and Diagnosis through Crowd-Sourced Games: A Malaria Case Study
Mavandadi, S., Dimitrov, S., Feng, S., Yu, F., Sikora, U., Yaglidere, O., Padmanabhan, S., Nielsen, K., & Ozcan, A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037245 · Cited by 122
Automated screening of sickle cells using a smartphone-based microscope and deep learning
de Haan, K., Koydemir, H. C., Rivenson, Y., Tseng, D., Dyne, E. V., Bakic, L., Karinca, D., Liang, K., Ilango, M., Gumustekin, E., et al. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0282-y · Cited by 138
Luengo-Oroz, M. A., Arranz, A., & Frean, J. (2012) · Journal of Medical Internet Research · doi:10.2196/jmir.2338 · Cited by 136
Interfacing Pathogen Detection with Smartphones for Point-of-Care Applications
Ding, X., Mauk, M. G., Yin, K., Kadimisetty, K., & Liu, C. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04973 · Cited by 135
Field-portable reflection and transmission microscopy based on lensless holography
Lee, M., Yaglidere, O., & Özcan, A. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.002721 · Cited by 135
Sickle cell detection using a smartphone
Knowlton, S. M., Şencan, İ., Aytar, Y., Khoory, J. A., Heeney, M. M., Ghiran, I. C., & Taşoğlu, S. (2015) · Scientific Reports · doi:10.1038/srep15022 · Cited by 132
Mobile-platform based colorimeter for monitoring chlorine concentration in water
Sumriddetchkajorn, S., Chaitavon, K., & Intaravanne, Y. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.10.024 · Cited by 131
PhotoMetrix and colorimetric image analysis using smartphones
Böck, F. C., Helfer, G. A., da Costa, A. B., Dessuy, M. B., & Ferrão, M. F. (2020) · Journal of Chemometrics · doi:10.1002/cem.3251 · Cited by 131
Unconventional methods of imaging: computational microscopy and compact implementations
McLeod, E. J., & Özcan, A. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/7/076001 · Cited by 129
Smart-phone based computational microscopy using multi-frame contact imaging on a fiber-optic array
Navruz, İ., Coskun, A. F., Wong, J., Mohammad, S., Tseng, D. K., Nagi, R., Phillips, S. W., & Özcan, A. (2013) · Lab on a Chip · doi:10.1039/c3lc50589h · Cited by 128
Metadata
- Authors
- Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A.
- Affiliations
- University of California, San Francisco (US)
- University of California, Berkeley (US)
- Corresponding author
- Fletcher, Daniel A.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2009-07-22
- Volume
- 4
- Issue
- 7
- Pages
- e6320
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC2709430
- OpenAlex
- W2104431608
- Cited by
- 694
- References
- 20
- Citations by year
- 2026: 14 · 2025: 14 · 2024: 18 · 2023: 27 · 2022: 27 · 2021: 46 · 2020: 42 · 2019: 48 · 2018: 66 · 2017: 52 · 2016: 53 · 2015: 59 · 2014: 71 · 2013: 46 · 2012: 52
- FWCI
- 40.78
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Science Foundation
- Microsoft Research
- University of California Berkeley
- Blum Center for Developing Economies, University of California Berkeley
- Center for Information Technology Research in the Interest of Society
- University of California, San Francisco
- National Defense Science and Engineering Graduate
- Center for Information Technology
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Digital Imaging for Blood Diseases
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- optical microscopy, telemedicine, malaria diagnosis, Plasmodium falciparum, sickle red blood cells, tuberculosis, Mycobacterium tuberculosis, sputum smear microscopy, fluorescence microscopy, image analysis, resource-limited settings
- MeSH terms
- Anemia, Sickle Cell, Animals, Equipment Design, Fluorescence, Humans, Microscopy, Mycobacterium tuberculosis, Plasmodium falciparum, Tuberculosis, Global Health, Cell Phone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.