CoChat

Mobile Phone Based Clinical Microscopy for Global Health Applications

Open access

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

Light microscopy provides a simple, cost-effective, and vital method for the diagnosis and screening of hematologic and infectious diseases. In many regions of the world, however, the required equipment is either unavailable or insufficiently portable, and operators may not possess adequate training to make full use of the images obtained. Counterintuitively, these same regions are often well served by mobile phone networks, suggesting the possibility of leveraging portable, camera-enabled mobile phones for diagnostic imaging and telemedicine. Toward this end we have built a mobile phone-mounted light microscope and demonstrated its potential for clinical use by imaging P. falciparum-infected and sickle red blood cells in brightfield and M. tuberculosis-infected sputum samples in fluorescence with LED excitation. In all cases resolution exceeded that necessary to detect blood cell and microorganism morphology, and with the tuberculosis samples we took further advantage of the digitized images to demonstrate automated bacillus counting via image analysis software. We expect such a telemedicine system for global healthcare via mobile phone -- offering inexpensive brightfield and fluorescence microscopy integrated with automated image analysis -- to provide an important tool for disease diagnosis and screening, particularly in the developing world and rural areas where laboratory facilities are scarce but mobile phone infrastructure is extensive.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0006320

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Mobile phone microscopy layout schematic, prototype, and sample images. (a) Mobile phone microscopy optical layout for fluorescence imaging. The same apparatus was used for brightfield imaging, with the filters and LED removed. Components only required for fluorescence imaging are indicated by “fluo.” Not to scale. (b) A current prototype, with filters and LED installed, capable of fluorescence imaging. The objective is not visible because it is contained within the optical tubing, and the sample is mounted adjacent to the metallic focusing knob. (c) Brightfield image of 6 µm fluorescent beads. (d) Fluorescent images of beads shown in (c). The field-of-view projected onto the camera phone CMOS is outlined. Scales bars are 10 µm.
Figure 1 Mobile phone microscopy layout schematic, prototype, and sample images. (a) Mobile phone microscopy optical layout for fluorescence imaging. The same apparatus was used for brightfield imaging, with the filters and LED removed. Components only required for fluorescence imaging are indicated by “fluo.” Not to scale. (b) A current prototype, with filters and LED installed, capable of fluorescence imaging. The objective is not visible because it is contained within the optical tubing, and the sample is mounted adjacent to the metallic focusing knob. (c) Brightfield image of 6 µm fluorescent beads. (d) Fluorescent images of beads shown in (c). The field-of-view projected onto the camera phone CMOS is outlined. Scales bars are 10 µm.CC BY · PubMed Central
Figure 2 Mobile phone microscopy images of diseased blood smears. (a) Thick smear of Giemsa-stained malaria-infected blood. (b) Thin smear of Giemsa-stained malaria-infected blood. (c) Sickle-cell anaemia blood smear. White arrows point to two sickled red blood cells. Scale bars are 10 µm.
Figure 2 Mobile phone microscopy images of diseased blood smears. (a) Thick smear of Giemsa-stained malaria-infected blood. (b) Thin smear of Giemsa-stained malaria-infected blood. (c) Sickle-cell anaemia blood smear. White arrows point to two sickled red blood cells. Scale bars are 10 µm.CC BY · PubMed Central
Figure 3 Fluorescence mobile phone microscopy images of tuberculosis in sputum. (a) Fluorescence image of Auramine O-stained TB sputum sample. (b) Enlarged view of two tuberculosis bacilli from red-outlined area in (a). (c) Automated counting of fluorescently-labeled tuberculosis bacilli; counted bacilli are numbered and set to red in the image. Scale bars in (a) and (c) are 10 µm, scale bar in (b) is 1 µm.
Figure 3 Fluorescence mobile phone microscopy images of tuberculosis in sputum. (a) Fluorescence image of Auramine O-stained TB sputum sample. (b) Enlarged view of two tuberculosis bacilli from red-outlined area in (a). (c) Automated counting of fluorescently-labeled tuberculosis bacilli; counted bacilli are numbered and set to red in the image. Scale bars in (a) and (c) are 10 µm, scale bar in (b) is 1 µm.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Research works printed but not linked: 2

  1. [15]WHO SEARO/WPRO Workshop on Quality Assurance for Malaria Microscopy 2005 Malaria light microscopy: creating a culture of quality. Kuala Lumpus, Malaysia
  2. [21]International Union Against Tuberculosis and Lung Disease 2000 Sputum Examination for Tuberculosis by Direct Microscopy in Low Income Countries, Fifth edition. Paris, France

Cited by

Items 401–500 of 761

Metadata

Authors
Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A.
Affiliations
  • University of California, San Francisco (US)
  • University of California, Berkeley (US)
Corresponding author
Fletcher, Daniel A.
Venue
PLoS ONE
Published
2009-07-22
Volume
4
Issue
7
Pages
e6320
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2104431608
Cited by
694
References
20
Citations by year
2026: 14 · 2025: 14 · 2024: 18 · 2023: 27 · 2022: 27 · 2021: 46 · 2020: 42 · 2019: 48 · 2018: 66 · 2017: 52 · 2016: 53 · 2015: 59 · 2014: 71 · 2013: 46 · 2012: 52
FWCI
40.78
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • National Science Foundation
  • Microsoft Research
  • University of California Berkeley
  • Blum Center for Developing Economies, University of California Berkeley
  • Center for Information Technology Research in the Interest of Society
  • University of California, San Francisco
  • National Defense Science and Engineering Graduate
  • Center for Information Technology
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Digital Imaging for Blood Diseases
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
  • Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
Keywords
optical microscopy, telemedicine, malaria diagnosis, Plasmodium falciparum, sickle red blood cells, tuberculosis, Mycobacterium tuberculosis, sputum smear microscopy, fluorescence microscopy, image analysis, resource-limited settings
MeSH terms
Anemia, Sickle Cell, Animals, Equipment Design, Fluorescence, Humans, Microscopy, Mycobacterium tuberculosis, Plasmodium falciparum, Tuberculosis, Global Health, Cell Phone

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.