Mobile Phone Based Clinical Microscopy for Global Health Applications
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Light microscopy provides a simple, cost-effective, and vital method for the diagnosis and screening of hematologic and infectious diseases. In many regions of the world, however, the required equipment is either unavailable or insufficiently portable, and operators may not possess adequate training to make full use of the images obtained. Counterintuitively, these same regions are often well served by mobile phone networks, suggesting the possibility of leveraging portable, camera-enabled mobile phones for diagnostic imaging and telemedicine. Toward this end we have built a mobile phone-mounted light microscope and demonstrated its potential for clinical use by imaging P. falciparum-infected and sickle red blood cells in brightfield and M. tuberculosis-infected sputum samples in fluorescence with LED excitation. In all cases resolution exceeded that necessary to detect blood cell and microorganism morphology, and with the tuberculosis samples we took further advantage of the digitized images to demonstrate automated bacillus counting via image analysis software. We expect such a telemedicine system for global healthcare via mobile phone -- offering inexpensive brightfield and fluorescence microscopy integrated with automated image analysis -- to provide an important tool for disease diagnosis and screening, particularly in the developing world and rural areas where laboratory facilities are scarce but mobile phone infrastructure is extensive.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Mobile-based light microscopy offers a cheaper and more transportable tool for diagnosing infectious and haematological conditions (70, 73).”
From Assessing the impact of mHealth interventions in low- and middle-income countries – what has been shown to work? (2014) · cites this paper as [70]
The cited source says what the claim attributes to it.
In the citing paper
“Importantly, images can be captured by community health workers (CHWs) and transmitted wirelessly for diagnosis by doctors (45, 70).”
From Assessing the impact of mHealth interventions in low- and middle-income countries – what has been shown to work? (2014) · cites this paper as [70]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
National electrical manufacturers association
(1926) · Journal of the A.I.E.E. · doi:10.1109/jaiee.1926.6537344 · Cited by 860
Fluorescence versus conventional sputum smear microscopy for tuberculosis: a systematic review
Steingart, K. R., Henry, M., Ng, V., Hopewell, P. C., Ramsay, A., Cunningham, J., Urbanczik, R., Perkins, M., Aziz, M. A., & Pai, M. (2006) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(06)70578-3 · Cited by 798
Mobile e-Health: The Unwired Evolution of Telemedicine
Tachakra, S., Wang, X. H., Istepanian, R. S. H., & Song, Y. H. (2003) · Telemedicine Journal and e-Health · doi:10.1089/153056203322502632 · Cited by 252
Steingart, K. R., Henry, M., Laal, S., Hopewell, P. C., Ramsay, A., Menzies, D., Cunningham, J., Weldingh, K., & Pai, M. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040202 · Cited by 238
IEEE Transactions on Information Technology in Biomedicine
(2025) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.4233 · Cited by 230
Design of a telemedicine system using a mobile telephone
Woodward, B., Istepanian, R. S. H., & Richards, C. I. (2001) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.908361 · Cited by 166
Tshilolo, L. M., Kafando, É., Sawadogo, M., COTTON, F. J., Vertongen, F., Ferster, A., & Gulbis, B. (2008) · Public Health · doi:10.1016/j.puhe.2007.12.005 · Cited by 120
Telemedical Wound Care Using a New Generation of Mobile Telephones: A Feasibility Study
Braun, R. P., Vecchietti, J. L., Thomas, L., Prins, C., French, L. E., Gewirtzman, A. J., Saurat, J.-H., & Salomon, D. (2005) · Archives of Dermatology · doi:10.1001/archderm.141.2.254 · Cited by 118
A New Concept for Medical Imaging Centered on Cellular Phone Technology
Granot, Y., Ivorra, A., & Rubinsky, B. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002075 · Cited by 86
Research works printed but not linked: 2
- [15]WHO SEARO/WPRO Workshop on Quality Assurance for Malaria Microscopy 2005 Malaria light microscopy: creating a culture of quality. Kuala Lumpus, Malaysia
- [21]International Union Against Tuberculosis and Lung Disease 2000 Sputum Examination for Tuberculosis by Direct Microscopy in Low Income Countries, Fifth edition. Paris, France
Cited by
Items 401–500 of 761
Optofluidic single-cell absorption flow analyzer for point-of-care diagnosis of malaria
Banoth, E., Kasula, V. K., Jagannadh, V. K., & Gorthi, S. S. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201500118 · Cited by 14
In the Spotlight: BioInstrumentation
Yamakoshi, K.-I. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2089616 · Cited by 14
Sudewi, S., Li, C., Penki, V. S. S., Zulfajri, M., Meitei, N. J., & Huang, G. G. (2024) · ACS Omega · doi:10.1021/acsomega.4c08644 · Cited by 13
Clinical laboratory data: acquire, analyze, communicate, liberate
Azzazy, H. M. E.-S., & Elbehery, A. H. A. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.08.019 · Cited by 15
Hussain, I., & Nath, P. (2015) · Applied Optics · doi:10.1364/ao.54.005739 · Cited by 13
Time-lapse contact microscopy of cell cultures based on non-coherent illumination
Marion, G., Balle, D., Bigault, S., Pornin, C., Gétin, S., Perraut, F., Block, M. R., Chatelain, F., Picollet-D’hahan, N., Gidrol, X., et al. (2015) · Scientific Reports · doi:10.1038/srep14532 · Cited by 13
Vashist, S. K., & Luong, J. H. T. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-811762-0.00016-5 · Cited by 13
A METHOD FOR DETERMINING THE DARK RESPONSE FOR SCIENTIFIC IMAGING WITH SMARTPHONES
Igoe, D. P., Parisi, A. V., & Carter, B. (2014) · Instrumentation Science & Technology · doi:10.1080/10739149.2014.915557 · Cited by 13
Chun, H. J., Han, Y. D., Park, Y., Kim, K., Lee, S., & Yoon, H. C. (2018) · Materials · doi:10.3390/ma11030388 · Cited by 13
Improving the limit of detection in portable luminescent assay readers through smart optical design
Li, Y., Ma, X., Wang, W., Yan, S., Liu, F., Chu, K., Xu, G., & Smith, Z. J. (2019) · Journal of Biophotonics · doi:10.1002/jbio.201900241 · Cited by 13
Request redirection paradigm in medical image archive implementation
Драган, Д., & Ivetić, D. (2011) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2011.06.001 · Cited by 13
Fuh, Y., & Lai, Z.-H. (2016) · Optics Communications · doi:10.1016/j.optcom.2016.10.029 · Cited by 13
Four channels multi-illumination single-holographic-exposure lensless Fresnel (MISHELF) microscopy
Sanz, M., Picazo-Bueno, J. Á., Granero, L., García, J., & Micó, V. (2018) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2018.06.020 · Cited by 13
Smart Vital Signs Monitoring and Novel Falls Prediction System for older adults
Baig, M. M. (2014) · Tuwhera (Auckland University of Technology) · Cited by 13
Deng, Y., Yang, W., Li, J., Zhang, X., Rao, Y., Chen, H., Xiong, J., Chen, X., Wang, X., & Jin, X. (2025) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2025.110281 · Cited by 12
On the diffraction of a high-NA aplanatic and stigmatic singlet
González-Acuña, R. G., Borne, J., & Thibault, S. (2021) · Journal of the Optical Society of America A · doi:10.1364/josaa.425629 · Cited by 12
Rabha, D., Biswas, S., Hatiboruah, D., Das, P., Rather, M. A., Mandal, M., & Nath, P. (2022) · The Analyst · doi:10.1039/d1an02317a · Cited by 12
Ball Lens‐Assisted Cellphone Imaging with Submicron Resolution
Jin, B., Jean, A. R., Maslov, A. V., & Astratov, V. N. (2023) · Laser & Photonics Review · doi:10.1002/lpor.202300146 · Cited by 12
Dual characterization of biological cells by optofluidic microscope and resistive pulse sensor
Guo, J., Chen, L., Huang, X., Li, C. M., Ai, Y., & Kang, Y. (2014) · Electrophoresis · doi:10.1002/elps.201400268 · Cited by 12
Automated cell viability assessment using a microfluidics based portable imaging flow analyzer
Jagannadh, V. K., Adhikari, J. V., & Gorthi, S. S. (2015) · Biomicrofluidics · doi:10.1063/1.4919402 · Cited by 12
Supporting collaboration among healthcare professionals and disease surveillance in remote areas
Luz, S. F., Masoodian, M., Cesário, M., & Rogers, B. (2012) · Proceedings - IEEE Symposium on Computer-Based Medical Systems · doi:10.1109/cbms.2012.6266333 · Cited by 12
Blood Count on a Smartphone Microscope
Moravapalle, U. P., Deshpande, A., Kapoor, A., Ramjee, R., & Ravi, P. (2017) · IEEE Workshop on Mobile Computing Systems and Applications (WMCSA) · doi:10.1145/3032970.3032986 · Cited by 12
Micro-optical Components for Bioimaging on Tissues, Cells and Subcellular Structures
Yang, H., Zhang, Y., Chen, S., & Hao, R. (2019) · Micromachines · doi:10.3390/mi10060405 · Cited by 12
Hong, X., Lu, T., Fruzyna, L., & Yu, B. (2019) · Scientific Reports · doi:10.1038/s41598-019-52327-x · Cited by 12
Santa, N., Keleş, Ç., Saylor, J. R., & Sarver, E. A. (2021) · Minerals · doi:10.3390/min11080838 · Cited by 12
All-plastic miniature fluorescence microscope for point-of-care readout of bead-based bioassays
Forcucci, A., Pawlowski, M. E., Crannell, Z. A., Pavlova, I., Richards-Kortum, R. R., & Tkaczyk, T. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.10.105010 · Cited by 12
The role of biomedical engineering in disaster management in resource-limited settings
Fernandes, A., & Zaman, M. H. (2012) · Bulletin of the World Health Organization · doi:10.2471/blt.12.104901 · Cited by 12
Soni, G. K., Wangoo, N., & Sharma, R. K. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.109906 · Cited by 11
A Microfiltration Device for Urogenital Schistosomiasis Diagnostics
Xiao, Y., Lu, Y., Hsieh, M. H., Liao, J. C., & Wong, P. K. (2016) · PLoS ONE · doi:10.1371/journal.pone.0154640 · Cited by 11
Espinoza-Portilla, E., Henríquez-Suárez, M., & Cadenas, G. J. V. (2019) · ACTA MEDICA PERUANA · doi:10.35663/amp.2019.362.817 · Cited by 13
Jurczyszyn, K., & Kozakiewicz, M. (2020) · Materials · doi:10.3390/ma13163614 · Cited by 11
A high‐performance cell‐phone based polarized microscope for malaria diagnosis
Yu, Z., Li, Y., Deng, L., Luo, B., Wu, P., & Geng, D. (2022) · Journal of Biophotonics · doi:10.1002/jbio.202200290 · Cited by 11
İçöz, K. (2016) · Applied Sciences · doi:10.3390/app6100279 · Cited by 11
Smartphone-Enabled Detection Strategies for Portable PCR–Based Diagnostics
Priye, A., & Ugaz, V. M. (2017) · Methods in molecular biology · doi:10.1007/978-1-4939-6848-0_16 · Cited by 11
Ita, O. I., Otu, A. A., Onyedibe, K. I., Iwuafor, A. A., Banwat, E. B., & Egah, D. Z. (2018) · Transactions of the Royal Society of Tropical Medicine and Hygiene · doi:10.1093/trstmh/try071 · Cited by 11
Optical Design of an LED Lighting Source for Fluorescence Microscopes
Kuo, T.-C., Ding, T.-J., Lin, J.-H., & Ma, S. (2019) · Applied Sciences · doi:10.3390/app9214574 · Cited by 11
Laser Speckle Contrast Imaging Based on a Mobile Phone Camera
Kong, P., Xu, H., Li, R., Huang, G., & Liu, W. (2021) · IEEE Access · doi:10.1109/access.2021.3076799 · Cited by 11
Human–Device Interaction in the Life Science Laboratory
Söldner, R., Rheinländer, S., Meyer, T., Olszowy, M. W., & Austerjost, J. (2022) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2021_183 · Cited by 11
Emerging Optical Techniques for Detection of Oral, Cervical and Anal Cancer in Low-Resource Settings
Yu, B., Ferris, D. G., Liu, Y., & Nagarajan, V. K. (2014) · e-Publications@Marquette (Marquette University) · Cited by 11
Fuh, Y., Chen, P.-W., & Lai, Z.-H. (2016) · Journal of Modern Optics · doi:10.1080/09500340.2015.1128007 · Cited by 11
Design of New Procedures for Diagnosing Prevalent Diseases Using a Low-Cost Telemicroscopy System
Prieto-Egido, I., González-Escalada, A., García-Giganto, V., & Martínez-Fernández, A. (2016) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2015.0208 · Cited by 11
Development of inexpensive blood imaging systems: where are we now?
Chu, K., Smith, Z. J., & Wachsmann‐Hogiu, S. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2015.1075388 · Cited by 10
Smartphone-based flow cytometry
Li, Z., Zhang, S., & Wei, Q. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817044-1.00005-3 · Cited by 10
Magnetic field sensor based on plasmonic fiber optics coupled with smartphone
Ilbeygi, E., Jahanbakhshian, M., Pirlar, M. A., & Karimzadeh, R. (2021) · Optics & Laser Technology · doi:10.1016/j.optlastec.2021.107065 · Cited by 10
Albuquerque, T., Rosado, L., Cruz, R., Vasconcelos, M. J. M., Oliveira, T., & Cardoso, J. S. (2023) · Intelligent Systems with Applications · doi:10.1016/j.iswa.2022.200170 · Cited by 10
How to distinguish elastically scattered light from Stokes shifted light for solid-state lighting?
Meretska, M. L., Lagendijk, A., Thyrrestrup, H., Mosk, A. P., IJzerman, W. L., & Vos, W. L. (2016) · Journal of Applied Physics · doi:10.1063/1.4941688 · Cited by 10
Distinguishing between whole cells and cell debris using surface plasmon coupled emission
Talukder, M. A., Menyuk, C. R., & Kostov, Y. V. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.001977 · Cited by 10
Wang, H., Heintzmann, R., & Diederich, B. (2021) · Advanced Optical Technologies · doi:10.1515/aot-2021-0013 · Cited by 10
Foldscope: A smartphone based diagnostic tool for fungal keratitis
Parmar, D. P., Rathod, J., Karkhanawala, M., Bhole, P. K., & Rathod, D. (2021) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_3331_20 · Cited by 10
Smartphone-based clinical diagnostics
Zhang, S., Tis, T. B., & Wei, Q. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-819178-1.00048-4 · Cited by 10
A dual-mode mobile phone microscope using the onboard camera flash and ambient lightPreprint
Orth, A., Wilson, E. R., Thompson, J. G., & Gibson, B. C. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/162008 · Cited by 10
Ssentongo, P., Candela, X., Amoah, A. K. S., Opare, J. N., Arkorful, T. E., Tsai, A., Amponsah‐Manu, F., & Oh, J. S. (2018) · Journal of Pediatric Surgery Case Reports · doi:10.1016/j.epsc.2018.04.015 · Cited by 9
Applications of smartphones in analysis: Challenges and solutions
de Jesus, J. R., Ferrão, M. F., da Costa, A. B., Helfer, G. A., & Arruda, M. A. Z. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823696-3.00009-x · Cited by 9
Automated quantitative cytological analysis using portable microfluidic microscopy
Jagannadh, V. K., Murthy, R. S., Srinivasan, R., & Gorthi, S. S. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201500108 · Cited by 9
Development of a mobile phone camera-based transcutaneous bilirubinometer for low-resource settings
Harrison-Smith, B., Dumont, A. P., Arefin, M. S., Sun, Y., Lawal, N., Dobson, D., Nwaba, A., Grossarth, S. N., Paed, A. M., Farouk, Z. L., et al. (2022) · Biomedical Optics Express · doi:10.1364/boe.449625 · Cited by 9
A community based vaccination strategy over mobile phone records
Zhang, B., Cheng, X., Bie, R., & Chen, D. (2012) · ACM Workshop on Mobile Systems, Applications, and Services for Healthcare (mHealthSys) · doi:10.1145/2396276.2396279 · Cited by 9
From Telecytology to Mobile Cytopathology: Past, Present, and Future
Pouliakis, A., Archondakis, S. K., Margari, N., & Karakitsos, P. (2016) · Advances in healthcare information systems and administration book series · doi:10.4018/978-1-4666-9861-1.ch012 · Cited by 9
Wang, W., Yu, Y. P., & Huang, H. (2018) · Measurement · doi:10.1016/j.measurement.2018.04.081 · Cited by 9
Commercially Available Smartphone-Based Personalized Mobile Healthcare Technologies
Vashist, S. K., & Luong, J. H. T. (2019) · Springer eBooks · doi:10.1007/978-3-030-11416-9_3 · Cited by 9
Mobile-phone-based Rheinberg microscope with a light-emitting diode array
Ogasawara, Y., Sugimoto, R., Maruyama, R., Arimoto, H., Tamada, Y., & Watanabe, W. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.3.031007 · Cited by 9
Ayubi, G. A., & Dubra, A. (2023) · Optics Express · doi:10.1364/oe.512233 · Cited by 8
Portable optofluidic absorption flow analyzer for quantitative malaria diagnosis from whole blood
Banoth, E., Kasula, V. K., & Gorthi, S. S. (2016) · Applied Optics · doi:10.1364/ao.55.008637 · Cited by 8
Kundu, T. K., Anguraj, D. K., & Bhattacharyya, D. (2024) · Traitement du signal · doi:10.18280/ts.410129 · Cited by 8
Variable focus smartphone based microscope using an elastomer liquid lens
Huang, H., Kang, W. M., & Zhao, Y. (2016) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2016.7421752 · Cited by 8
Biosensor: An Approach Towards a Sustainable Environment
Negi, N. P., & Choephel, T. (2020) · Springer eBooks · doi:10.1007/978-981-15-8346-9_3 · Cited by 8
Lab-on-a-chip (lab-on-a-phone) for analysis of blood and diagnosis of blood diseases
Akther, F., Nguyen, D. H. T., Zhang, J., Nguyen, N., & Ta, H. T. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823971-1.00009-x · Cited by 8
Korompili, G., Kanakaris, G., Ampatis, C., & Chronis, N. (2018) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2018.06.034 · Cited by 8
Multiplex Smartphone Diagnostics
Martinez-Hurtado, J. L., Yetisen, A. K., & Yun, S. H. (2016) · Methods in molecular biology · doi:10.1007/978-1-4939-6730-8_26 · Cited by 8
Shanmugam, A., Usmani, M., Mayberry, A., Perkins, D. L., & Holcomb, D. E. (2018) · PLoS ONE · doi:10.1371/journal.pone.0193797 · Cited by 8
Hussain, I., & Nath, P. (2018) · Review of Scientific Instruments · doi:10.1063/1.5040189 · Cited by 8
Flores, D., & Marzullo, T. (2021) · AJP Advances in Physiology Education · doi:10.1152/advan.00127.2020 · Cited by 7
Continuous stacking computational approach based automated microscope slide scanner
Murali, S., Adhikari, J. V., Jagannadh, V. K., & Gorthi, S. S. (2018) · Review of Scientific Instruments · doi:10.1063/1.5022549 · Cited by 7
Igoe, D. P., Parisi, A. V., Downs, N. J., Amar, A., & Turner, J. F. (2018) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2018.01.057 · Cited by 7
Low-power, low-cost urinalysis system with integrated dipstick evaluation and microscopic analysis
Smith, G. T., Li, L., Zhu, Y., & Bowden, A. K. (2018) · Lab on a Chip · doi:10.1039/c8lc00501j · Cited by 7
Cellular-phone-based system for transportation engineering applications
Obaidat, M. T. (2020) · Alexandria Engineering Journal · doi:10.1016/j.aej.2020.01.040 · Cited by 7
In the Spotlight: BioInstrumentation
Yamakoshi, K.-I. (2012) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2012.2227703 · Cited by 7
Byzova, N. A., Zherdev, A. V., Eskendirova, S. Z., Baltin, K., Унышева, Г. Б., Муканов, К. К., Ramankulov, Y. M., & Dzantiev, B. B. (2012) · Applied Biochemistry and Microbiology · doi:10.1134/s0003683812060026 · Cited by 7
Babu, H. U., Stork, W., & Rauhe, H. (2010) · Advances in Optoelectronics and Micro/nano-optics · doi:10.1109/aom.2010.5767157 · Cited by 7
Chang, T.-J., Lai, W.-Q., Chang, Y., Wang, C.-L., & Yang, D. (2021) · Journal of the Chinese Medical Association · doi:10.1097/jcma.0000000000000574 · Cited by 7
Automated Low-Cost Malaria Detection System in Thin Blood Slide Images Using Mobile Phones
Reni, S. K. (2014) · WestminsterResearch (University of Westminster) · doi:10.34737/964y1 · Cited by 7
Molecular Detection Methods for Forest Pathogens
Wu, J. C., Dai, T., Wang, X., & Wang, Y. (2025) · Critical Reviews in Plant Sciences · doi:10.1080/07352689.2025.2489776 · Cited by 6
Smartphone-based microfluidic devices
Hasanzadeh, A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818791-3.00014-0 · Cited by 6
Orthogonal-view microscope for the biomechanics investigations of aquatic organisms
Le, B. T., Auer, K. M., Lopez, D. A. R., Shum, J. P., Suarsana, B., Suh, G.-Y. K., Hedde, P. N., & Ahrar, S. (2024) · HardwareX · doi:10.1016/j.ohx.2024.e00533 · Cited by 6
Eftimov, T., Kostova, I., Peltekov, A., Hristova, K. A., BRABANT, D., Fouzar, S., & Nikolov, K. (2024) · Optics & Laser Technology · doi:10.1016/j.optlastec.2024.110965 · Cited by 6
A smartphone fluorometer – the lab-in-a-phone
Hossain, M. A., Canning, J., Ast, S., Yen, T. L., Rutledge, P. J., & Jamalipour, A. (2014) · Advanced Photonics · doi:10.1364/sensors.2014.seth2c.1 · Cited by 6
Shourav, M. K., Kim, K., Kim, S., & Kim, J. K. (2016) · Micromachines · doi:10.3390/mi7070125 · Cited by 6
Portable imaging viscometry for quantitative complex fluid measurements
Shabaniverki, S., Valdivia, A. A., & Juárez, J. J. (2019) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2019.05.009 · Cited by 6
4f Koehler Transmitted Illumination Condenser for Teaching and Low-Cost Microscopic Imaging
Madrid-Wolff, J. A., & Forero-Shelton, M. (2020) · The Biophysicist · doi:10.35459/tbp.2019.000113 · Cited by 6
Low cost spectrometer accessory for cell phone based optical sensor
Hu, P., Chen, Y., & Sonkusale, S. (2015) · IEEE Virtual Conference on Applications of Commercial Sensors (VCACS) · doi:10.1109/vcacs.2015.7439566 · Cited by 6
Bello, I. M., Umar, A. S., Akpan, G. U., Okeibunor, J., Shibeshi, C., Shibeshi, M. E., Chakauya, J., Fasil, T., Daniel, F., Mihigo, R., et al. (2021) · Journal of Immunological Sciences · doi:10.29245/2578-3009/2021/s2.1108 · Cited by 6
Application of Advances in Telemedicine for Long-Duration Space Flight
Descartin, K. S., Menger, R., & Watkins, S. (2015) · Cited by 6
Digital Health Technologies: Digital Innovations in Public Health
Kelly, C., & Kamil-Thomas, Z. (2019) · Encyclopedia of the UN sustainable development goals · doi:10.1007/978-3-319-95681-7_70 · Cited by 6
Govindaraju, H., Tahir, M. N., & Hassan, U. (2025) · The Analyst · doi:10.1039/d5an00487j · Cited by 5
A roadmap for the widespread adoption of frugal microscopes
Rahmoon, M. A., Hobson, C. M., Chew, T., & Aaron, J. (2025) · Nature Communications · doi:10.1038/s41467-025-63691-w · Cited by 5
Chen, S., Zhou, L. P., Wang, Y., Wang, C., Lei, Y., Luo, Y., & Zhao, J. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c06395 · Cited by 5
NTDscope: A multi-contrast portable microscope for disease diagnosis
Derby, M. D. D. L., Moussa, Z. L., Ng, C. F., Bhuiya, A. M., Cabrera, J. P., Banik, D., Delahunt, C. B., Keller, M. D., Ny, A.-L. M. L., García-Villena, J., et al. (2026) · PLOS Global Public Health · doi:10.1371/journal.pgph.0005937 · Cited by 5
Self-citationField-Portable Microfluidics-Based Imaging Flow Cytometer
Jagannadh, V. K., Murthy, R. S., Srinivasan, R., & Gorthi, S. S. (2015) · Journal of Lightwave Technology · doi:10.1109/jlt.2015.2412654 · Cited by 5
A handheld, cell phone-based electrochemical biodetector
Lillehoj, P. B., Huang, M.-C., & Ho, C. (2013) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2013.6474174 · Cited by 5
Microfluidics for Fast and Frugal Diagnosis of Malaria, Sepsis, and HIV/AIDS
Tay, A. K. P., Khoo, B. L., & Warkiani, M. E. (2018) · Springer eBooks · doi:10.1007/978-3-319-66647-1_4 · Cited by 5
Smartphone-based nanodevices for in-field diagnosis
Majhi, K. C., Karfa, P., & Madhuri, R. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-817923-9.00006-7 · Cited by 5
Metadata
- Authors
- Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A.
- Affiliations
- University of California, San Francisco (US)
- University of California, Berkeley (US)
- Corresponding author
- Fletcher, Daniel A.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2009-07-22
- Volume
- 4
- Issue
- 7
- Pages
- e6320
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC2709430
- OpenAlex
- W2104431608
- Cited by
- 694
- References
- 20
- Citations by year
- 2026: 14 · 2025: 14 · 2024: 18 · 2023: 27 · 2022: 27 · 2021: 46 · 2020: 42 · 2019: 48 · 2018: 66 · 2017: 52 · 2016: 53 · 2015: 59 · 2014: 71 · 2013: 46 · 2012: 52
- FWCI
- 40.78
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Science Foundation
- Microsoft Research
- University of California Berkeley
- Blum Center for Developing Economies, University of California Berkeley
- Center for Information Technology Research in the Interest of Society
- University of California, San Francisco
- National Defense Science and Engineering Graduate
- Center for Information Technology
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Digital Imaging for Blood Diseases
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- optical microscopy, telemedicine, malaria diagnosis, Plasmodium falciparum, sickle red blood cells, tuberculosis, Mycobacterium tuberculosis, sputum smear microscopy, fluorescence microscopy, image analysis, resource-limited settings
- MeSH terms
- Anemia, Sickle Cell, Animals, Equipment Design, Fluorescence, Humans, Microscopy, Mycobacterium tuberculosis, Plasmodium falciparum, Tuberculosis, Global Health, Cell Phone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.