Mobile Phone Based Clinical Microscopy for Global Health Applications
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Light microscopy provides a simple, cost-effective, and vital method for the diagnosis and screening of hematologic and infectious diseases. In many regions of the world, however, the required equipment is either unavailable or insufficiently portable, and operators may not possess adequate training to make full use of the images obtained. Counterintuitively, these same regions are often well served by mobile phone networks, suggesting the possibility of leveraging portable, camera-enabled mobile phones for diagnostic imaging and telemedicine. Toward this end we have built a mobile phone-mounted light microscope and demonstrated its potential for clinical use by imaging P. falciparum-infected and sickle red blood cells in brightfield and M. tuberculosis-infected sputum samples in fluorescence with LED excitation. In all cases resolution exceeded that necessary to detect blood cell and microorganism morphology, and with the tuberculosis samples we took further advantage of the digitized images to demonstrate automated bacillus counting via image analysis software. We expect such a telemedicine system for global healthcare via mobile phone -- offering inexpensive brightfield and fluorescence microscopy integrated with automated image analysis -- to provide an important tool for disease diagnosis and screening, particularly in the developing world and rural areas where laboratory facilities are scarce but mobile phone infrastructure is extensive.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Mobile-based light microscopy offers a cheaper and more transportable tool for diagnosing infectious and haematological conditions (70, 73).”
From Assessing the impact of mHealth interventions in low- and middle-income countries – what has been shown to work? (2014) · cites this paper as [70]
The cited source says what the claim attributes to it.
In the citing paper
“Importantly, images can be captured by community health workers (CHWs) and transmitted wirelessly for diagnosis by doctors (45, 70).”
From Assessing the impact of mHealth interventions in low- and middle-income countries – what has been shown to work? (2014) · cites this paper as [70]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
National electrical manufacturers association
(1926) · Journal of the A.I.E.E. · doi:10.1109/jaiee.1926.6537344 · Cited by 860
Fluorescence versus conventional sputum smear microscopy for tuberculosis: a systematic review
Steingart, K. R., Henry, M., Ng, V., Hopewell, P. C., Ramsay, A., Cunningham, J., Urbanczik, R., Perkins, M., Aziz, M. A., & Pai, M. (2006) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(06)70578-3 · Cited by 798
Mobile e-Health: The Unwired Evolution of Telemedicine
Tachakra, S., Wang, X. H., Istepanian, R. S. H., & Song, Y. H. (2003) · Telemedicine Journal and e-Health · doi:10.1089/153056203322502632 · Cited by 252
Steingart, K. R., Henry, M., Laal, S., Hopewell, P. C., Ramsay, A., Menzies, D., Cunningham, J., Weldingh, K., & Pai, M. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040202 · Cited by 238
IEEE Transactions on Information Technology in Biomedicine
(2025) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.4233 · Cited by 230
Design of a telemedicine system using a mobile telephone
Woodward, B., Istepanian, R. S. H., & Richards, C. I. (2001) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.908361 · Cited by 166
Tshilolo, L. M., Kafando, É., Sawadogo, M., COTTON, F. J., Vertongen, F., Ferster, A., & Gulbis, B. (2008) · Public Health · doi:10.1016/j.puhe.2007.12.005 · Cited by 120
Telemedical Wound Care Using a New Generation of Mobile Telephones: A Feasibility Study
Braun, R. P., Vecchietti, J. L., Thomas, L., Prins, C., French, L. E., Gewirtzman, A. J., Saurat, J.-H., & Salomon, D. (2005) · Archives of Dermatology · doi:10.1001/archderm.141.2.254 · Cited by 118
A New Concept for Medical Imaging Centered on Cellular Phone Technology
Granot, Y., Ivorra, A., & Rubinsky, B. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002075 · Cited by 86
Research works printed but not linked: 2
- [15]WHO SEARO/WPRO Workshop on Quality Assurance for Malaria Microscopy 2005 Malaria light microscopy: creating a culture of quality. Kuala Lumpus, Malaysia
- [21]International Union Against Tuberculosis and Lung Disease 2000 Sputum Examination for Tuberculosis by Direct Microscopy in Low Income Countries, Fifth edition. Paris, France
Cited by
Items 101–200 of 761
Inorganic Complexes and Metal-Based Nanomaterials for Infectious Disease Diagnostics
Markwalter, C. F., Kantor, A. G., Moore, C. P., Richardson, K. A., & Wright, D. W. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00136 · Cited by 128
Mobile device-based self-referencing colorimeter for monitoring chlorine concentration in water
Sumriddetchkajorn, S., Chaitavon, K., & Intaravanne, Y. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.03.080 · Cited by 128
Emerging Technologies for Point-of-Care Management of HIV Infection
Shafiee, H., Wang, S., İnci, F., Toy, M., Henrich, T. J., Kuritzkes, D. R., & Demirci, U. (2014) · Annual Review of Medicine · doi:10.1146/annurev-med-092112-143017 · Cited by 123
Paterson, A. S., Raja, B., Vinay, M., Townsend, B., Lee, M., Buell, A., Vu, B. V., Brgoch, J., & Willson, R. C. (2017) · Lab on a Chip · doi:10.1039/c6lc01167e · Cited by 122
Rapid and Reliable Assessment of the Contrast Sensitivity Function on an iPad
Dörr, M., Lesmes, L. A., Lu, Z., & Bex, P. J. (2013) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.13-11743 · Cited by 121
Real Time Blood Testing Using Quantitative Phase Imaging
Pham, H. V., Bhaduri, B., Tangella, K. V., Best-Popescu, C. A., & Popescu, G. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055676 · Cited by 119
Low-cost, sub-micron resolution, wide-field computational microscopy using opensource hardware
Aidukas, T., Eckert, R. F., Harvey, A. R., Waller, L., & Konda, P. C. (2019) · Scientific Reports · doi:10.1038/s41598-019-43845-9 · Cited by 119
Smartphone-interfaced 3D printed toxicity biosensor integrating bioluminescent “sentinel cells”
Cevenini, L., Calabretta, M. M., Tarantino, G., Michelini, E., & Roda, A. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.11.017 · Cited by 119
Bogoch, I. I., Andrews, J. R., Speich, B., Utzinger, J., Ame, S. M., Ali, S. M., & Keiser, J. (2013) · The American Society of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.12-0742 · Cited by 110
Lab-in-a-Phone: Smartphone-Based Portable Fluorometer for pH Measurements of Environmental Water
Hossain, A., Canning, J., Ast, S., Rutledge, P. J., Yen, T. L., & Jamalipour, A. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2361651 · Cited by 115
Roadmap on Label‐Free Super‐Resolution Imaging
Astratov, V. N., Sahel, Y. B., Eldar, Y. C., Huang, L., Özcan, A., Zheludev, N. I., Zhao, J., Burns, Z., Liu, Z., Narimanov, E. E., et al. (2023) · Laser & Photonics Review · doi:10.1002/lpor.202200029 · Cited by 114
Smartphone based bacterial detection using biofunctionalized fluorescent nanoparticles
Rajendran, V. K., Bakthavathsalam, P., & Ali, B. M. J. (2014) · Microchimica Acta · doi:10.1007/s00604-014-1242-5 · Cited by 112
Smartphone based LSPR sensing platform for bio-conjugation detection and quantification
Dutta, S., Saikia, K., & Nath, P. (2016) · RSC Advances · doi:10.1039/c6ra01113f · Cited by 112
Counting White Blood Cells from a Blood Smear Using Fourier Ptychographic Microscopy
Chung, J., Ou, X., Kulkarni, R. P., & Yang, C. (2015) · PLoS ONE · doi:10.1371/journal.pone.0133489 · Cited by 109
Advances in microfluidics in combating infectious diseases
Tay, A. K. P., Pavesi, A., Yazdi, S. R., Lim, C. T., & Warkiani, M. E. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.02.002 · Cited by 109
Point-of-care and point-of-procedure optical imaging technologies for primary care and global health
Boppart, S. A., & Richards-Kortum, R. R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3009725 · Cited by 109
Point-of-care nucleic acid detection using nanotechnology
Hartman, M. R., Ruiz, R. C. H., Hamada, S., Xu, C., Yancey, K. G., Yu, Y., Han, W., & Luo, D. (2013) · Nanoscale · doi:10.1039/c3nr04015a · Cited by 106
Smartphone-based optical analysis systems
Nonno, S. D., & Ulber, R. (2021) · The Analyst · doi:10.1039/d1an00025j · Cited by 104
Multi-Contrast Imaging and Digital Refocusing on a Mobile Microscope with a Domed LED Array
Phillips, Z. F., D’Ambrosio, M. V., Tian, L., Rulison, J. J., Patel, H. S., Sadras, N., Gande, A. V., Switz, N. A., Fletcher, D. A., & Waller, L. (2015) · PLoS ONE · doi:10.1371/journal.pone.0124938 · Cited by 104
Self-citationOptical fiber smartphone spectrometer
Hossain, M. A., Canning, J., Cook, K. T., & Jamalipour, A. (2016) · Optics Letters · doi:10.1364/ol.41.002237 · Cited by 103
Fabricating low cost and high performance elastomer lenses using hanging droplets
Lee, W. M., Upadhya, A., Reece, P. J., & Phan, T. G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.001626 · Cited by 103
Meng, X., Huang, H., Yan, K., Tian, X., Yu, W., Cui, H., Kong, Y., Xue, L., Liu, C., & Wang, S. (2016) · Lab on a Chip · doi:10.1039/c6lc01321j · Cited by 102
Luppa, P. B., Bietenbeck, A., Beaudoin, C. A., & Giannetti, A. E. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.01.003 · Cited by 103
Digital health for the End TB Strategy: developing priority products and making them work
Falzon, D., Timimi, H., Kurosinski, P., Migliori, G. B., Gemert, W. V., Denkinger, C. M., Isaacs, C., Story, A., Garfein, R. S., Bastos, L. G. D. V., et al. (2016) · European Respiratory Journal · doi:10.1183/13993003.00424-2016 · Cited by 102
A beginner’s guide to rigor and reproducibility in fluorescence imaging experiments
Lee, J., & Kitaoka, M. (2018) · Molecular Biology of the Cell · doi:10.1091/mbc.e17-05-0276 · Cited by 96
Smartphone apps in microbiology—is better regulation required?
Visvanathan, A., Hamilton, A., & Brady, R. R. W. (2012) · Clinical Microbiology and Infection · doi:10.1111/j.1469-0691.2012.03892.x · Cited by 95
Chen, W., Yu, H., Sun, F., Ornob, A., Brisbin, R., Ganguli, A., Vemuri, V., Strzebonski, P., Cui, G., Allen, K. J., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02478 · Cited by 96
Recent developments towards portable point-of-care diagnostic devices for pathogen detection
Roy, S., Arshad, F., Eissa, S., Safavieh, M., Alattas, S. G., Ahmed, M. U., & Zourob, M. M. (2021) · Sensors & Diagnostics · doi:10.1039/d1sd00017a · Cited by 95
Field-Portable Pixel Super-Resolution Colour Microscope
Greenbaum, A., Akbari, N., Feizi, A., Luo, W., & Özcan, A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0076475 · Cited by 95
Preechaburana, P., Suska, A., & Filippini, D. (2014) · Trends in biotechnology · doi:10.1016/j.tibtech.2014.03.007 · Cited by 94
Ephraim, R. K. D., Duah, E., Cybulski, J. S., Prakash, M., D’Ambrosio, M. V., Fletcher, D. A., Keiser, J., Andrews, J. R., & Bogoch, I. I. (2015) · American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.14-0741 · Cited by 94
Self-citationMobile health to improve tuberculosis care and control: a call worth making [Review article]
Denkinger, C. M., Grenier, J., Stratis, A. K., Akkihal, A., Pant-Pai, N., & Pai, M. (2013) · The International Journal of Tuberculosis and Lung Disease · doi:10.5588/ijtld.12.0638 · Cited by 78
Mobile microscopy as a screening tool for oral cancer in India: A pilot study
Skandarajah, A., Sunny, S. P., Gurpur, P., Reber, C. D., D’Ambrosio, M. V., Raghavan, N., James, B. L., Ramanjinappa, R. D., Suresh, A., Kandasarma, U., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0188440 · Cited by 92
Self-citationLee, W., Shrivastava, S., Duy, L. T., Kim, B. Y., Son, Y.-M., & Lee, N. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.03.061 · Cited by 92
A Handheld Point-of-Care Genomic Diagnostic System
Myers, F. B., Henrikson, R. H., Bone, J. M., & Lee, L. P. (2013) · PLoS ONE · doi:10.1371/journal.pone.0070266 · Cited by 92
A Smartphone‐Enabled Portable Digital Light Processing 3D Printer
Li, W., Wang, M., Mille, L. S., Robledo, J. A., Huerta, V., Uribe-Velázquez, T., Cheng, F., Li, H., Gong, J., Ching, T., et al. (2021) · Advanced Materials · doi:10.1002/adma.202102153 · Cited by 91
Field-portable lensfree tomographic microscope
Isikman, S. O., Bishara, W., Sikora, U., Yaglidere, O., Yeah, J., & Özcan, A. (2011) · Lab on a Chip · doi:10.1039/c1lc20127a · Cited by 90
Long, Z., Mao, L., Liu, M., Wan, Q., Wan, Y., Zhang, X., & Wei, Y. (2017) · Polymer Chemistry · doi:10.1039/c7py00979h · Cited by 90
A sensor-centric survey on the development of smartphone measurement and sensing systems
Grossi, M. (2018) · Measurement · doi:10.1016/j.measurement.2018.12.014 · Cited by 90
Ludwig, S. K. J., Zhu, H., Phillips, S. W., Shiledar, A., Feng, S. W., Tseng, D. K., van Ginkel, L. A., Nielen, M. W. F., & Özcan, A. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7984-4 · Cited by 90
Fluorescence analyzer based on smartphone camera and wireless for detection of Ochratoxin A
Bueno, D., Muñoz, R., & Marty, J. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.03.140 · Cited by 89
Selck, D. A., Karymov, M. A., Sun, B., & Ismagilov, R. F. (2013) · Analytical Chemistry · doi:10.1021/ac4030413 · Cited by 88
FPscope: a field-portable high-resolution microscope using a cellphone lens
Dong, S., Guo, K., Nanda, P., Shiradkar, R., & Zheng, G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.003305 · Cited by 87
Smartphone adapters for digital photomicrography
Roy, S., Pantanowitz, L., Amin, M., Seethala, R. R., Ahmed, I., Yousem, S. A., Parwani, A. V., Cucoranu, L., & Hartman, D. J. (2014) · Journal of Pathology Informatics · doi:10.4103/2153-3539.137728 · Cited by 86
A portable low-cost long-term live-cell imaging platform for biomedical research and education
Walzik, M. P., Vollmar, V., Lachnit, T., Dietz, H., Haug, S., Bachmann, H., Fath, M., Aschenbrenner, D., Mofrad, S. A., Friedrich, O., et al. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.061 · Cited by 86
LudusScope: Accessible Interactive Smartphone Microscopy for Life-Science Education
Kim, H., Gerber, L. C., Chiu, D., Lee, S. A., Cira, N., Xia, S. Y., & Riedel-Kruse, I. H. (2016) · PLoS ONE · doi:10.1371/journal.pone.0162602 · Cited by 86
Medical diagnostics with mobile devices: Comparison of intrinsic and extrinsic sensing
Kwon, L., Long, K. D., Wan, Y., Yu, H., & Cunningham, B. T. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.02.010 · Cited by 84
Plasmonics Enhanced Smartphone Fluorescence Microscopy
Wei, Q., Acuna, G. P., Kim, S., Vietz, C., Tseng, D. K., Chae, J., Shir, D. J.-L., Luo, W., Tinnefeld, P., & Özcan, A. (2017) · Scientific Reports · doi:10.1038/s41598-017-02395-8 · Cited by 84
Automated Tuberculosis Diagnosis Using Fluorescence Images from a Mobile Microscope
Chang, J., Arbeláez, P., Switz, N. A., Reber, C. D., Tapley, A., Davis, J. L., Cattamanchi, A., Fletcher, D. A., & Malik, J. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-33454-2_43 · Cited by 82
Self-citationOptofluidic opportunities in global health, food, water and energy
Chen, Y., Jiang, L., Mancuso, M., Jain, A., Oncescu, V., & Erickson, D. (2012) · Nanoscale · doi:10.1039/c2nr30859b · Cited by 82
Lee, S. A., Leitao, R. M., Zheng, G., Yang, S., Rodríguez, A., & Yang, C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026127 · Cited by 80
Yetisen, A. K. (2014) · Springer theses · doi:10.1007/978-3-319-13584-7_6 · Cited by 79
Microfluidic Based Optical Microscopes on Chip
Paiè, P., Vàzquez, R. M., Osellame, R., Bragheri, F., & Bassi, A. L. (2018) · Cytometry Part A · doi:10.1002/cyto.a.23589 · Cited by 80
A dual-mode mobile phone microscope using the onboard camera flash and ambient light
Orth, A., Wilson, E. R., Thompson, J. G., & Gibson, B. C. (2018) · Scientific Reports · doi:10.1038/s41598-018-21543-2 · Cited by 78
Selective near-perfect absorbing mirror as a spatial frequency filter for optical image processing
Wesemann, L., Panchenko, E., Singh, K., Gaspera, E. D., Gómez, D. E., Davis, T. J., & Roberts, A. (2019) · APL Photonics · doi:10.1063/1.5113650 · Cited by 78
Smartphone with optical, physical, and electrochemical nanobiosensors
Seo, S. E., Tabei, F., Park, S. J., Askarian, B., Kim, K. H., Moallem, G., Chong, J. W., & Kwon, O. S. (2019) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2019.04.037 · Cited by 77
Open-source do-it-yourself multi-color fluorescence smartphone microscopy
Sung, Y., Campa, F., & Shih, W.-C. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.005075 · Cited by 76
Shin, D., Pierce, M. C., Gillenwater, A. M., Williams, M. D., & Richards-Kortum, R. R. (2010) · PLoS ONE · doi:10.1371/journal.pone.0011218 · Cited by 76
From Cleanroom to Desktop: Emerging Micro-Nanofabrication Technology for Biomedical Applications
Pan, T., & Wang, W. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0218-9 · Cited by 75
Group III nitride nanomaterials for biosensing
Li, X., & Liu, X. (2017) · Nanoscale · doi:10.1039/c7nr01577a · Cited by 75
Su, K., Zou, Q., Zhou, J., Zou, L., Li, H., Wang, T., Hu, N., & Wang, P. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.04.052 · Cited by 74
Increasing Clinical Presence of Mobile Communication Technology: Avoiding the Pitfalls
Visvanathan, A., Gibb, A. P., & Brady, R. R. W. (2011) · Telemedicine and e-Health · doi:10.1089/tmj.2011.0018 · Cited by 64
Shah, M. I., Mishra, S., Yadav, V. K., Chauhan, A., Sarkar, M. S., Sharma, S. K., & Rout, C. (2017) · Journal of medical imaging · doi:10.1117/1.jmi.4.2.027503 · Cited by 74
Raabin-WBC: a large free access dataset of white blood cells from normal peripheral bloodPreprint
Kouzehkanan, Z. M., Saghari, S., Tavakoli, E., Rostami, P., Abaszadeh, M., Mirzadeh, F., Satlsar, E. S., Gheidishahran, M., Gorgi, F., Mohammadi, S., et al. (2021) · Research Square · doi:10.1101/2021.05.02.442287 · Cited by 71
Global Digital Cultures: Perspectives from South Asia
Punathambekar, A., & Mohan, S. (2018) · University of Michigan Press eBooks · doi:10.3998/mpub.9561751 · Cited by 124
Ground and river water quality monitoring using a smartphone-based pH sensor
Dutta, S., Sarma, D. J., & Nath, P. (2015) · AIP Advances · doi:10.1063/1.4921835 · Cited by 69
Quanti.us: a tool for rapid, flexible, crowd-based annotation of images
Hughes, A. J., Mornin, J. D., Biswas, S. K., Beck, L. E., Bauer, D. P., Raj, A., Bianco, S., & Gartner, Z. J. (2018) · Nature Methods · doi:10.1038/s41592-018-0069-0 · Cited by 64
McPartlin, D. A., & O’Kennedy, R. J. (2014) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.2014.960516 · Cited by 68
Mobile phone imaging and cloud-based analysis for standardized malaria detection and reporting
Scherr, T., Gupta, S. L., Wright, D. W., & Haselton, F. R. (2016) · Scientific Reports · doi:10.1038/srep28645 · Cited by 68
Compact, cost-effective and field-portable microscope prototype based on MISHELF microscopy
Sanz, M., Picazo-Bueno, J. Á., Granero, L., García, J., & Micó, V. (2017) · Scientific Reports · doi:10.1038/srep43291 · Cited by 68
An ultra-sensitive colorimetric sensor based on smartphone for pyrophosphate determination
Dong, C., Ma, X., Qiu, N., Zhang, Y., & Wu, A. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.129066 · Cited by 67
Khalaf, E. M., Jabbar, H. S., Romero‐Parra, R. M., Al‐Awsi, G. R. L., Budi, H. S., Altamimi, A. S. A., Gatea, M. A., Falih, K. T., Singh, K., & Alkhuzai, K. A. (2023) · Microchemical Journal · doi:10.1016/j.microc.2023.108692 · Cited by 67
Mobile Digital Fluorescence Microscopy for Diagnosis of Tuberculosis
Tapley, A., Switz, N. A., Reber, C. D., Davis, J. L., Miller, C. R., Matovu, J., Worodria, W. O., Huang, L., Fletcher, D. A., & Cattamanchi, A. (2013) · Journal of Clinical Microbiology · doi:10.1128/jcm.03432-12 · Cited by 67
Self-citationLabel‐Free Sickle Cell Disease Diagnosis using a Low‐Cost, Handheld Platform
Yenilmez, B., Knowlton, S. M., Yu, C. H., Heeney, M. M., & Taşoğlu, S. (2016) · Advanced Materials Technologies · doi:10.1002/admt.201600100 · Cited by 66
Vietz, C., Schütte, M. L., Wei, Q., Richter, L., Lalkens, B., Özcan, A., Tinnefeld, P., & Acuna, G. P. (2019) · ACS Omega · doi:10.1021/acsomega.8b03136 · Cited by 66
Prasad, K., Winter, J., Bhat, U. M., Acharya, R. V., & Prabhu, K. G. (2011) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-011-9442-6 · Cited by 65
Smartphone-based optical spectroscopic platforms for biomedical applications: a review [Invited]
Hussain, I., & Bowden, A. K. (2021) · Biomedical Optics Express · doi:10.1364/boe.416753 · Cited by 65
A Smartphone-Based Fourier Ptychographic Microscope Using the Display Screen for Illumination
Lee, K. C., Lee, K., Jung, J., Lee, S. H., Kim, D., & Lee, S. A. (2021) · ACS Photonics · doi:10.1021/acsphotonics.1c00350 · Cited by 64
Shrivas, K. K., Monisha, M., Patel, S., Thakur, S. S., & Shankar, R. (2020) · Lab on a Chip · doi:10.1039/d0lc00515k · Cited by 64
Liu, Y., Rollins, A. M., Levenson, R. M., Fereidouni, F., & Jenkins, M. W. (2021) · Communications Biology · doi:10.1038/s42003-021-01860-5 · Cited by 64
Surface Plasmon Resonance Chemical Sensing on Cell Phones
Preechaburana, P., Gonzalez, M. C., Suska, A., & Filippini, D. (2012) · Angewandte Chemie · doi:10.1002/ange.201206804 · Cited by 64
Biosensors as rapid diagnostic tests for tropical diseases
Teles, F., Tavira, L. A. P. D. T., & Fonseca, L. P. (2010) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408363.2010.518405 · Cited by 64
Tecnologías móviles para la salud pública en el Perú: lecciones aprendidas
Ruíz, E., Proaño, Á., Ponce, O. J., & Curioso, W. H. (2015) · Revista Peruana de Medicina Experimental y Salud Pública · doi:10.17843/rpmesp.2015.322.1634 · Cited by 64
Smartphones for Cell and Biomolecular Detection
Liu, X., Lin, T.-Y., & Lillehoj, P. B. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1055-z · Cited by 63
Microfluidic method for measuring viscosity using images from smartphone
Kim, S., Kim, K. C., & Yeom, E. (2017) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2017.05.016 · Cited by 63
Microfluidic devices for diagnostic applications
Eicher, D., & Merten, C. A. (2011) · Expert Review of Molecular Diagnostics · doi:10.1586/erm.11.25 · Cited by 64
Ambient light-based optical biosensing platform with smartphone-embedded illumination sensor
Park, Y. M., Han, Y. D., Chun, H. J., & Yoon, H. C. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.007 · Cited by 62
Biomedical imaging and sensing using flatbed scanners
Göröcs, Z. S., & Özcan, A. (2014) · Lab on a Chip · doi:10.1039/c4lc00530a · Cited by 61
Giga-Pixel Lensfree Holographic Microscopy and Tomography Using Color Image Sensors
Isikman, S. O., Greenbaum, A., Luo, W., Coskun, A. F., & Özcan, A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0045044 · Cited by 61
Mobile App-Based Quantitative Scanometric Analysis
Wong, J. X. H., Liu, F. S. F., & Yu, H. (2014) · Analytical Chemistry · doi:10.1021/ac5035727 · Cited by 61
Tuijn, C. J., Hoefman, B. J., van Beijma, H., Oskam, L., & Chevrollier, N. (2011) · PLoS ONE · doi:10.1371/journal.pone.0028348 · Cited by 60
Haney, K. E., Tandon, P., Divi, R. L., Ossandon, M. R., Baker, H., & Pearlman, P. C. (2017) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2017.2761764 · Cited by 59
Albert, H., Manabe, Y. C., Lukyamuzi, G., Ademun, P. J., Mukkada, S. T., Nyesiga, B., Joloba, M. L., Paramasivan, C. N., & Perkins, M. D. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015206 · Cited by 58
Counting Molecules with a Mobile Phone Camera Using Plasmonic Enhancement
Ayas, S., Çupallari, A., Ekiz, O. Ö., Kaya, Y., & Dâna, A. (2013) · ACS Photonics · doi:10.1021/ph400108p · Cited by 58
Sargazi, M., & Kaykhaii, M. (2019) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2019.117672 · Cited by 58
Shambhu, S., Koundal, D., Das, P., Hoang, V. T., Tran-Trung, K., & Turabieh, H. (2022) · Computational Intelligence and Neuroscience · doi:10.1155/2022/3626726 · Cited by 58
Smartphone-assisted detection of nucleic acids by light-harvesting FRET-based nanoprobe
Severi, C., Melnychuk, N., & Klymchenko, A. S. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112515 · Cited by 57
Dadkhah, S., Mehdinia, A., Jabbari, A., & Manbohi, A. (2020) · Microchimica Acta · doi:10.1007/s00604-020-04543-w · Cited by 56
Evanescent Wave Coupled Spectroscopic Sensing Using Smartphone
Dutta, S., Choudhury, A., & Nath, P. (2014) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2013.2297700 · Cited by 55
Development of a flow-free magnetic actuation platform for an automated microfluidic ELISA
Coarsey, C., Coleman, B., Kabir, M. A., Sher, M., & Asghar, W. (2019) · RSC Advances · doi:10.1039/c8ra07607c · Cited by 55
Metadata
- Authors
- Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A.
- Affiliations
- University of California, San Francisco (US)
- University of California, Berkeley (US)
- Corresponding author
- Fletcher, Daniel A.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2009-07-22
- Volume
- 4
- Issue
- 7
- Pages
- e6320
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC2709430
- OpenAlex
- W2104431608
- Cited by
- 694
- References
- 20
- Citations by year
- 2026: 14 · 2025: 14 · 2024: 18 · 2023: 27 · 2022: 27 · 2021: 46 · 2020: 42 · 2019: 48 · 2018: 66 · 2017: 52 · 2016: 53 · 2015: 59 · 2014: 71 · 2013: 46 · 2012: 52
- FWCI
- 40.78
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Science Foundation
- Microsoft Research
- University of California Berkeley
- Blum Center for Developing Economies, University of California Berkeley
- Center for Information Technology Research in the Interest of Society
- University of California, San Francisco
- National Defense Science and Engineering Graduate
- Center for Information Technology
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Digital Imaging for Blood Diseases
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- optical microscopy, telemedicine, malaria diagnosis, Plasmodium falciparum, sickle red blood cells, tuberculosis, Mycobacterium tuberculosis, sputum smear microscopy, fluorescence microscopy, image analysis, resource-limited settings
- MeSH terms
- Anemia, Sickle Cell, Animals, Equipment Design, Fluorescence, Humans, Microscopy, Mycobacterium tuberculosis, Plasmodium falciparum, Tuberculosis, Global Health, Cell Phone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.