Mobile Phone Based Clinical Microscopy for Global Health Applications
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Light microscopy provides a simple, cost-effective, and vital method for the diagnosis and screening of hematologic and infectious diseases. In many regions of the world, however, the required equipment is either unavailable or insufficiently portable, and operators may not possess adequate training to make full use of the images obtained. Counterintuitively, these same regions are often well served by mobile phone networks, suggesting the possibility of leveraging portable, camera-enabled mobile phones for diagnostic imaging and telemedicine. Toward this end we have built a mobile phone-mounted light microscope and demonstrated its potential for clinical use by imaging P. falciparum-infected and sickle red blood cells in brightfield and M. tuberculosis-infected sputum samples in fluorescence with LED excitation. In all cases resolution exceeded that necessary to detect blood cell and microorganism morphology, and with the tuberculosis samples we took further advantage of the digitized images to demonstrate automated bacillus counting via image analysis software. We expect such a telemedicine system for global healthcare via mobile phone -- offering inexpensive brightfield and fluorescence microscopy integrated with automated image analysis -- to provide an important tool for disease diagnosis and screening, particularly in the developing world and rural areas where laboratory facilities are scarce but mobile phone infrastructure is extensive.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Mobile-based light microscopy offers a cheaper and more transportable tool for diagnosing infectious and haematological conditions (70, 73).”
From Assessing the impact of mHealth interventions in low- and middle-income countries – what has been shown to work? (2014) · cites this paper as [70]
The cited source says what the claim attributes to it.
In the citing paper
“Importantly, images can be captured by community health workers (CHWs) and transmitted wirelessly for diagnosis by doctors (45, 70).”
From Assessing the impact of mHealth interventions in low- and middle-income countries – what has been shown to work? (2014) · cites this paper as [70]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
National electrical manufacturers association
(1926) · Journal of the A.I.E.E. · doi:10.1109/jaiee.1926.6537344 · Cited by 860
Fluorescence versus conventional sputum smear microscopy for tuberculosis: a systematic review
Steingart, K. R., Henry, M., Ng, V., Hopewell, P. C., Ramsay, A., Cunningham, J., Urbanczik, R., Perkins, M., Aziz, M. A., & Pai, M. (2006) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(06)70578-3 · Cited by 798
Mobile e-Health: The Unwired Evolution of Telemedicine
Tachakra, S., Wang, X. H., Istepanian, R. S. H., & Song, Y. H. (2003) · Telemedicine Journal and e-Health · doi:10.1089/153056203322502632 · Cited by 252
Steingart, K. R., Henry, M., Laal, S., Hopewell, P. C., Ramsay, A., Menzies, D., Cunningham, J., Weldingh, K., & Pai, M. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040202 · Cited by 238
IEEE Transactions on Information Technology in Biomedicine
(2025) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.4233 · Cited by 230
Design of a telemedicine system using a mobile telephone
Woodward, B., Istepanian, R. S. H., & Richards, C. I. (2001) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.908361 · Cited by 166
Tshilolo, L. M., Kafando, É., Sawadogo, M., COTTON, F. J., Vertongen, F., Ferster, A., & Gulbis, B. (2008) · Public Health · doi:10.1016/j.puhe.2007.12.005 · Cited by 120
Telemedical Wound Care Using a New Generation of Mobile Telephones: A Feasibility Study
Braun, R. P., Vecchietti, J. L., Thomas, L., Prins, C., French, L. E., Gewirtzman, A. J., Saurat, J.-H., & Salomon, D. (2005) · Archives of Dermatology · doi:10.1001/archderm.141.2.254 · Cited by 118
A New Concept for Medical Imaging Centered on Cellular Phone Technology
Granot, Y., Ivorra, A., & Rubinsky, B. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002075 · Cited by 86
Digital Imaging and Communications in Medicine
Onken, M., Eichelberg, M., Riesmeier, J., & Jensch, P. F. (2010) · Biological and medical physics series · doi:10.1007/978-3-642-15816-2_17 · Cited by 81
Can the power of mobile phones be used to improve tuberculosis diagnosis in developing countries?
Zimic, M., Coronel, J., Gilman, R. H., Luna, C. G., Curioso, W. H., & Moore, D. A. J. (2009) · Transactions of the Royal Society of Tropical Medicine and Hygiene · doi:10.1016/j.trstmh.2008.10.015 · Cited by 68
Fluorescence microscopy for tuberculosis diagnosis
Hùng, N. V., Sy, D. N., Anthony, R. M., Cobelens, F. G. J., & van Soolingen, D. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70059-2 · Cited by 58
Streetly, A., Clarke, M., Downing, M., Farrar, L., Foo, Y., Hall, K., Kemp, H., Newbold, J., Walsh, P., YATES, J. L., et al. (2008) · Journal of Medical Screening · doi:10.1258/jms.2008.007063 · Cited by 52
Hendry, C., Dionne, K., Hedgepeth, A., Carroll, K. C., & Parrish, N. M. (2009) · Journal of Clinical Microbiology · doi:10.1128/jcm.02097-08 · Cited by 43
Fluorescence microscopy for tuberculosis diagnosis
Hänscheid, T., Ribeiro, C. M., Shapiro, H. M., & Perlmutter, N. G. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70058-0 · Cited by 38
Microscopic images transmitted by mobile cameraphone
Frean, J. (2007) · Transactions of the Royal Society of Tropical Medicine and Hygiene · doi:10.1016/j.trstmh.2007.06.008 · Cited by 31
McArthur revisited: fluorescence microscopes for field diagnostics
Jones, D. B., Nyalwidhe, J. O., Tetley, L., & Barrett, M. P. (2007) · Trends in Parasitology · doi:10.1016/j.pt.2007.08.003 · Cited by 25
Screening for sickle cell disease in newborns: recommendation statement.
(2008) · PubMed · Cited by 23
The Remote Diagnosis of Malaria Using Telemedicine or E-Mailed Images
Mody, R. M., Murray, C. K., Dooley, D. P., Hospenthal, D. R., Horvath, L. L., Moran, K. A., & Muntz, R. W. (2006) · Military Medicine · doi:10.7205/milmed.171.12.1167 · Cited by 22
Research works printed but not linked: 2
- [15]WHO SEARO/WPRO Workshop on Quality Assurance for Malaria Microscopy 2005 Malaria light microscopy: creating a culture of quality. Kuala Lumpus, Malaysia
- [21]International Union Against Tuberculosis and Lung Disease 2000 Sputum Examination for Tuberculosis by Direct Microscopy in Low Income Countries, Fifth edition. Paris, France
Cited by
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Miniaturized integration of a fluorescence microscope
Ghosh, K. K., Burns, L. D., Cocker, E. D., Nimmerjahn, A., Ziv, Y., Gamal, A. E., & Schnitzer, M. J. (2011) · Nature Methods · doi:10.1038/nmeth.1694 · Cited by 1,120
Amplification-free detection of SARS-CoV-2 with CRISPR-Cas13a and mobile phone microscopy
Fozouni, P., Son, S., Díaz de León Derby, M., Knott, G. J., Gray, C. N., D’Ambrosio, M. V., Zhao, C., Switz, N. A., Kumar, G. R., Stephens, S. I., et al. (2021) · Cell · doi:10.1016/j.cell.2020.12.001 · Cited by 1,047
Self-citation
Metadata
- Authors
- Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A.
- Affiliations
- University of California, San Francisco (US)
- University of California, Berkeley (US)
- Corresponding author
- Fletcher, Daniel A.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2009-07-22
- Volume
- 4
- Issue
- 7
- Pages
- e6320
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC2709430
- OpenAlex
- W2104431608
- Cited by
- 694
- References
- 20
- Citations by year
- 2026: 14 · 2025: 14 · 2024: 18 · 2023: 27 · 2022: 27 · 2021: 46 · 2020: 42 · 2019: 48 · 2018: 66 · 2017: 52 · 2016: 53 · 2015: 59 · 2014: 71 · 2013: 46 · 2012: 52
- FWCI
- 40.78
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Science Foundation
- Microsoft Research
- University of California Berkeley
- Blum Center for Developing Economies, University of California Berkeley
- Center for Information Technology Research in the Interest of Society
- University of California, San Francisco
- National Defense Science and Engineering Graduate
- Center for Information Technology
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Digital Imaging for Blood Diseases
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- optical microscopy, telemedicine, malaria diagnosis, Plasmodium falciparum, sickle red blood cells, tuberculosis, Mycobacterium tuberculosis, sputum smear microscopy, fluorescence microscopy, image analysis, resource-limited settings
- MeSH terms
- Anemia, Sickle Cell, Animals, Equipment Design, Fluorescence, Humans, Microscopy, Mycobacterium tuberculosis, Plasmodium falciparum, Tuberculosis, Global Health, Cell Phone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.