The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
A Glucose BioFuel Cell Implanted in Rats
Open accessAbstract
Powering future generations of implanted medical devices will require cumbersome transcutaneous energy transfer or harvesting energy from the human body. No functional solution that harvests power from the body is currently available, despite attempts to use the Seebeck thermoelectric effect, vibrations or body movements. Glucose fuel cells appear more promising, since they produce electrical energy from glucose and dioxygen, two substrates present in physiological fluids. The most powerful ones, Glucose BioFuel Cells (GBFCs), are based on enzymes electrically wired by redox mediators. However, GBFCs cannot be implanted in animals, mainly because the enzymes they rely on either require low pH or are inhibited by chloride or urate anions, present in the Extra Cellular Fluid (ECF). Here we present the first functional implantable GBFC, working in the retroperitoneal space of freely moving rats. The breakthrough relies on the design of a new family of GBFCs, characterized by an innovative and simple mechanical confinement of various enzymes and redox mediators: enzymes are no longer covalently bound to the surface of the electron collectors, which enables use of a wide variety of enzymes and redox mediators, augments the quantity of active enzymes, and simplifies GBFC construction. Our most efficient GBFC was based on composite graphite discs containing glucose oxidase and ubiquinone at the anode, polyphenol oxidase (PPO) and quinone at the cathode. PPO reduces dioxygen into water, at pH 7 and in the presence of chloride ions and urates at physiological concentrations. This GBFC, with electrodes of 0.133 mL, produced a peak specific power of 24.4 microW mL(-1), which is better than pacemakers' requirements and paves the way for the development of a new generation of implantable artificial organs, covering a wide range of medical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enzymatic Biofuel Cells for Implantable and Microscale Devices
Calabrese Barton, S., Gallaway, J., & Atanassov, P. (2004) · Chemical Reviews · doi:10.1021/cr020719k · Cited by 1,394
Enzymes as Working or Inspirational Electrocatalysts for Fuel Cells and Electrolysis
Cracknell, J. A., Vincent, K. A., & Armstrong, F. A. (2008) · Chemical Reviews · doi:10.1021/cr0680639 · Cited by 988
Journal of Electroanalytical Chemistry
(1960) · Nature · doi:10.1038/186124c0 · Cited by 777
Heller, A. (2004) · Physical Chemistry Chemical Physics · doi:10.1039/b313149a · Cited by 660
Minteer, S. D., Liaw, B. Y., & Cooney, M. J. (2007) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2007.03.007 · Cited by 504
Encyclopedia of Medical Devices and Instrumentation
(2006) · Wiley eBooks · doi:10.1002/0471732877 · Cited by 481
Energy harvesting by implantable abiotically catalyzed glucose fuel cells
Kerzenmacher, S., Ducrée, J., Zengerle, R., & von Stetten, F. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.03.031 · Cited by 374
A high-power glucose/oxygen biofuel cell operating under quiescent conditions
Sakai, H., Nakagawa, T., Tokita, Y., Hatazawa, T., Ikeda, T., Tsujimura, S., & Kano, K. (2009) · Energy Environ. Sci. · doi:10.1039/b809841g · Cited by 332
Soukharev, V., Mano, N., & Heller, A. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0475510 · Cited by 310
A wearable haemodialysis device for patients with end-stage renal failure: a pilot study
Davenport, A., Gura, V., Ronco, C., Beizai, M., Ezon, C., & Rambod, E. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61864-9 · Cited by 217
Cited by
Smart Textiles for Electricity Generation
Chen, G., Li, Y., Bick, M., & Chen, J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00821 · Cited by 931
Mediatorless high-power glucose biofuel cells based on compressed carbon nanotube-enzyme electrodes
Zebda, A., Gondran, C., Le Goff, A., Holzinger, M., Cinquin, P., & Cosnier, S. (2011) · Nature Communications · doi:10.1038/ncomms1365 · Cited by 615
Self-citationTackling the Challenges of Enzymatic (Bio)Fuel Cells
Xiao, X., Xia, H.-Q., Wu, R., Bai, L., Yan, L., Magner, E., Cosnier, S., Lojou, E., Zhu, Z., & Liu, A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00115 · Cited by 504
Self-citationImplanted Biofuel Cell Operating in a Living Snail
Halámková, L., Halámek, J., Bocharova, V., Szczupak, A., Alfonta, L., & Katz, E. (2012) · Journal of the American Chemical Society · doi:10.1021/ja211714w · Cited by 486
Enzymatic biofuel cells: 30 years of critical advancements
Rasmussen, M., Abdellaoui, S., & Minteer, S. D. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.029 · Cited by 483
Bandodkar, A. J., You, J.-M., Kim, N.-H., Gu, Y., Kumar, R., Mohan, A. M. V., Kurniawan, J., Imani, S., Nakagawa, T., Parish, B., et al. (2017) · Energy & Environmental Science · doi:10.1039/c7ee00865a · Cited by 412
Single Glucose Biofuel Cells Implanted in Rats Power Electronic Devices
Zebda, A., Cosnier, S., Alcaraz, J.-P., Holzinger, M., Le Goff, A., Gondran, C., Boucher, F., Giroud, F., Gorgy, K., Lamraoui, H., et al. (2013) · Scientific Reports · doi:10.1038/srep01516 · Cited by 370
Self-citationImplantable devices: issues and challenges
Bazaka, K., & Jacob, M. (2012) · Electronics · doi:10.3390/electronics2010001 · Cited by 358
“network of single-walled carbon nanotubes embedded in film that forms the cathode [97,98].”
Flexible Electrochemical Bioelectronics: The Rise of In Situ Bioanalysis
Yu, Y., Nyein, H. Y. Y., Gao, W., & Javey, A. (2020) · Advanced Materials · doi:10.1002/adma.201902083 · Cited by 349
Self-powered cardiovascular electronic devices and systems
Zheng, Q., Tang, Q., Wang, Z. L., & Li, Z. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0426-4 · Cited by 348
Energy Harvesting from the Animal/Human Body for Self-Powered Electronics
Dagdeviren, C., Li, Z., & Wang, Z. L. (2017) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071516-044517 · Cited by 348
Emerging Implantable Energy Harvesters and Self-Powered Implantable Medical Electronics
Jiang, D., Shi, B., Ouyang, H., Fan, Y., Wang, Z. L., & Li, Z. (2020) · ACS Nano · doi:10.1021/acsnano.9b08268 · Cited by 343
O2Reduction in Enzymatic Biofuel Cells
Mano, N., & de Poulpiquet, A. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00220 · Cited by 337
From “cyborg” lobsters to a pacemaker powered by implantable biofuel cells
MacVittie, K., Halámek, J., Halámková, L., Southcott, M., Jemison, W. D., Lobel, R., & Katz, E. (2013) · Energy Environ. Sci. · doi:10.1039/c2ee23209j · Cited by 332
Epidermal Biofuel Cells: Energy Harvesting from Human Perspiration
Jia, W., Valdés‐Ramírez, G., Bandodkar, A. J., Windmiller, J. R., & Wang, J. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201302922 · Cited by 324
Functional Fiber Materials to Smart Fiber Devices
Chen, C., Feng, J., Li, J., Guo, Y., Shi, X., & Peng, H. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00192 · Cited by 308
Piezoelectric energy harvesters for biomedical applications
Ali, F., Raza, W., Li, X., Gul, H., & Kim, K.-H. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.01.012 · Cited by 300
Towards glucose biofuel cells implanted in human body for powering artificial organs: Review
Cosnier, S., Le Goff, A., & Holzinger, M. (2014) · Electrochemistry Communications · doi:10.1016/j.elecom.2013.09.021 · Cited by 291
Self-citationImplantable Energy‐Harvesting Devices
Shi, B., Li, Z., & Fan, Y. (2018) · Advanced Materials · doi:10.1002/adma.201801511 · Cited by 290
Zhou, M., & Dong, S. (2011) · Accounts of Chemical Research · doi:10.1021/ar200096g · Cited by 279
An Implantable Biofuel Cell for a Live Insect
Rasmussen, M., Ritzmann, R. E., Lee, I., Pollack, A. J., & Scherson, D. (2012) · Journal of the American Chemical Society · doi:10.1021/ja210794c · Cited by 270
Living battery – biofuel cells operating in vivo in clams
Szczupak, A., Halámek, J., Halámková, L., Bocharova, V., Alfonta, L., & Katz, E. (2012) · Energy & Environmental Science · doi:10.1039/c2ee21626d · Cited by 259
Challenges for successful implantation of biofuel cells
Zebda, A., Alcaraz, J.-P., Vadgama, P., Shleev, S., Minteer, S. D., Boucher, F., Cinquin, P., & Martin, D. K. (2018) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2018.05.011 · Cited by 224
Self-citationWearable Biofuel Cells: A Review
Bandodkar, A. J., & Wang, J. (2016) · Electroanalysis · doi:10.1002/elan.201600019 · Cited by 193
Powering implantable and ingestible electronics
Yang, S., Sencadas, V., You, S. S., Jia, N. Z., Srinivasan, S. S., Huang, H., Ahmed, A. E., Liang, J. Y., & Traverso, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009289 · Cited by 183
Substrate specificity mapping of fungal CAZy AA3_2 oxidoreductases
(2024) · doi:10.1186/s13068-024-02491-8 · Cited by 7
Metadata
- Authors
- Cinquin, P., Gondran, C., Giroud, F., Mazabrard, S., Pellissier, A., Boucher, F., Alcaraz, J.-P., Gorgy, K., Lenouvel, F., Mathé, S., Porcu, P., & Cosnier, S.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2010-05-04
- Volume
- 5
- Issue
- 5
- Pages
- e10476
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W1976707687
- Cited by
- 413
- References
- 18
- FWCI
- 23.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.