The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Serial Section Scanning Electron Microscopy (S3EM) on Silicon Wafers for Ultra-Structural Volume Imaging of Cells and Tissues
Open accessAbstract
High resolution, three-dimensional (3D) representations of cellular ultrastructure are essential for structure function studies in all areas of cell biology. While limited subcellular volumes have been routinely examined using serial section transmission electron microscopy (ssTEM), complete ultrastructural reconstructions of large volumes, entire cells or even tissue are difficult to achieve using ssTEM. Here, we introduce a novel approach combining serial sectioning of tissue with scanning electron microscopy (SEM) using a conductive silicon wafer as a support. Ribbons containing hundreds of 35 nm thick sections can be generated and imaged on the wafer at a lateral pixel resolution of 3.7 nm by recording the backscattered electrons with the in-lens detector of the SEM. The resulting electron micrographs are qualitatively comparable to those obtained by conventional TEM. S(3)EM images of the same region of interest in consecutive sections can be used for 3D reconstructions of large structures. We demonstrate the potential of this approach by reconstructing a 31.7 µm(3) volume of a calyx of Held presynaptic terminal. The approach introduced here, Serial Section SEM (S(3)EM), for the first time provides the possibility to obtain 3D ultrastructure of large volumes with high resolution and to selectively and repetitively home in on structures of interest. S(3)EM accelerates process duration, is amenable to full automation and can be implemented with standard instrumentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The structure of the nervous system of the nematode Caenorhabditis elegans
White, J. G., Southgate, E., Thomson, J. N., & Brenner, S. (1986) · Philosophical Transactions of the Royal Society of London. B, Biological Sciences · doi:10.1098/rstb.1986.0056 · Cited by 5,589 · cited 1×
“This lack of large volume ssTEM data is likely due to the fact that ssTEM, even when semiautomated, is time consuming [8,11] as it took about a decade to fully image and reconstruct the entire nervous system of the small nematode Caenorhabditis elegans by this method [12].”
BackgroundExperience-dependent structural synaptic plasticity in the mammalian brain
Holtmaat, A., & Svoboda, K. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2699 · Cited by 1,934 · cited 1×
“the number of synaptic vesicles or size of the synapse) are important determinants of the functional state of the synapses [2].”
BackgroundSerial Block-Face Scanning Electron Microscopy to Reconstruct Three-Dimensional Tissue Nanostructure
Denk, W., & Horstmann, H. (2004) · PLoS Biology · doi:10.1371/journal.pbio.0020329 · Cited by 1,644 · cited 2×
“These methods include serial block-face scanning electron microscopy (SBFSEM) [14,15], and focal ion beam (FIB) milling [16].”
MethodSelf-citationLondon, M., & Häusser, M. (2005) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.28.061604.135703 · Cited by 1,149 · cited 1×
“However, in neurobiology, the precise mapping of the synaptic connections of a given neuron throughout its dendritic and axonal arborisations is essential, since the position of the synapses is an important determinant of the computational properties of the neuron [1].”
BackgroundWiring specificity in the direction-selectivity circuit of the retina
Briggman, K. L., Helmstaedter, M., & Denk, W. (2011) · Nature · doi:10.1038/nature09818 · Cited by 883 · cited 5×
“It is less expensive than SBFSEM, FIB milling, TEMCA and electron tomography, because it can be performed with conventional electron microscopy equipment.”
MethodInfluentialMicheva, K. D., & Smith, S. J. (2007) · Neuron · doi:10.1016/j.neuron.2007.06.014 · Cited by 787
Synaptogenesis Via Dendritic Filopodia in Developing Hippocampal Area CA1
Fiala, J. C., Feinberg, M., Popov, V., & Harris, K. M. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-21-08900.1998 · Cited by 758
Serial section scanning electron microscopy of adult brain tissue using focused ion beam milling
Knott, G., Marchman, H., Wall, D., & Lich, B. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3189-07.2008 · Cited by 692
Cardona, A., Saalfeld, S., Preibisch, S., Schmid, B., Cheng, A., Pulokas, J., Tomancak, P., & Hartenstein, V. (2010) · PLoS Biology · doi:10.1371/journal.pbio.1000502 · Cited by 372
The organization of cytoplasm at the presynaptic active zone of a central nervous system synapse
Landis, D. M. D., Hall, A. K., Weinstein, L. A., & Reese, T. S. (1988) · Neuron · doi:10.1016/0896-6273(88)90140-7 · Cited by 333
Cited by
Brain tumour cells interconnect to a functional and resistant network
Osswald, M., Jung, E., Sahm, F., Solecki, G., Venkataramani, V., Blaes, J., Weil, S., Horstmann, H., Wiestler, B., Syed, M., et al. (2015) · Nature · doi:10.1038/nature16071 · Cited by 1,143
Self-citationGlioblastoma hijacks neuronal mechanisms for brain invasion
Venkataramani, V., Yang, Y., Schubert, M. C., Reyhan, E., Tetzlaff, S. K., Wißmann, N., Botz, M., Soyka, S. J., Beretta, C. A., Pramatarov, R. L., et al. (2022) · Cell · doi:10.1016/j.cell.2022.06.054 · Cited by 632
Self-citationExploring the third dimension: Volume electron microscopy comes of age
Peddie, C. J., & Collinson, L. M. (2014) · Micron · doi:10.1016/j.micron.2014.01.009 · Cited by 330
Volume scanning electron microscopy for imaging biological ultrastructure
Titze, B., & Genoud, C. (2016) · Biology of the Cell · doi:10.1111/boc.201600024 · Cited by 287
High‐resolution, high‐throughput imaging with a multibeam scanning electron microscope
EBERLE, A. L., MIKULA, S., SCHALEK, R., LICHTMAN, J., TATE, M. L. K., & ZEIDLER, D. (2015) · Journal of Microscopy · doi:10.1111/jmi.12224 · Cited by 254
Gas cluster ion beam SEM for imaging of large tissue samples with 10 nm isotropic resolution
Hayworth, K. J., Peale, D., Januszewski, M., Knott, G. W., Lu, Z., Xu, C. S., & Hess, H. F. (2020) · Nature Methods · doi:10.1038/s41592-019-0641-2 · Cited by 68
Oligodendrocyte calcium signaling promotes actin-dependent myelin sheath extension
Iyer, M., Kantarci, H., Cooper, M. H., Ambiel, N., Novak, S. W., Andrade, L. R., Lam, M., Jones, G., Münch, A. E., Yu, X., et al. (2024) · Nature Communications · doi:10.1038/s41467-023-44238-3 · Cited by 49
“Imaging of serial sections by scanning EM (S3EM) was conducted as previously described 97,98 , with some modi fi cations.”
MethodDarwisch, W., von Spangenberg, M., Lehmann, J., Singin, Ö., Deubert, G., Kühl, S., Roos, J., Horstmann, H., Körber, C., Hoppe, S., et al. (2020) · Communications Biology · doi:10.1038/s42003-020-01442-x · Cited by 32
Self-citationKrohs, C., Körber, C., Ebbers, L., Altaf, F., Hollje, G., Hoppe, S., Dörflinger, Y., Prosser, H. M., & Nothwang, H. G. (2021) · The Journal of Neuroscience · doi:10.1523/jneurosci.0139-20.2021 · Cited by 15
Self-citation
Metadata
- Authors
- Horstmann, H., Körber, C., Sätzler, K., Aydin, D., & Kuner, T.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2012-04-16
- Volume
- 7
- Issue
- 4
- Pages
- e35172
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2090416745
- Cited by
- 160
- References
- 13
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.