The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Validity of Six Activity Monitors in Chronic Obstructive Pulmonary Disease: A Comparison with Indirect Calorimetry
Open accessAbstract
Reduced physical activity is an important feature of Chronic Obstructive Pulmonary Disease (COPD). Various activity monitors are available but their validity is poorly established. The aim was to evaluate the validity of six monitors in patients with COPD. We hypothesized triaxial monitors to be more valid compared to uniaxial monitors. Thirty-nine patients (age 68±7 years, FEV(1) 54±18%predicted) performed a one-hour standardized activity protocol. Patients wore 6 monitors (Kenz Lifecorder (Kenz), Actiwatch, RT3, Actigraph GT3X (Actigraph), Dynaport MiniMod (MiniMod), and SenseWear Armband (SenseWear)) as well as a portable metabolic system (Oxycon Mobile). Validity was evaluated by correlation analysis between indirect calorimetry (VO(2)) and the monitor outputs: Metabolic Equivalent of Task [METs] (SenseWear, MiniMod), activity counts (Actiwatch), vector magnitude units (Actigraph, RT3) and arbitrary units (Kenz) over the whole protocol and slow versus fast walking. Minute-by-minute correlations were highest for the MiniMod (r = 0.82), Actigraph (r = 0.79), SenseWear (r = 0.73) and RT3 (r = 0.73). Over the whole protocol, the mean correlations were best for the SenseWear (r = 0.76), Kenz (r = 0.52), Actigraph (r = 0.49) and MiniMod (r = 0.45). The MiniMod (r = 0.94) and Actigraph (r = 0.88) performed better in detecting different walking speeds. The Dynaport MiniMod, Actigraph GT3X and SenseWear Armband (all triaxial monitors) are the most valid monitors during standardized physical activities. The Dynaport MiniMod and Actigraph GT3X discriminate best between different walking speeds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vestbo, J., Hurd, S. S., Agustí, A. G., Jones, P. W., Vogelmeier, C., Anzueto, A., Barnes, P. J., Fabbri, L. M., Martinez, F. J., Nishimura, M., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201204-0596pp · Cited by 15,983
Miller, M. R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Crapo, R., Enright, P., van der Grinten, C. P. M., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034805 · Cited by 15,627
ATS Statement: Guidelines for the Six-Minute Walk Test
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.166.1.at1102 · Cited by 11,195
(1985) · Europe PMC (PubMed Central) · Cited by 9,143
Lung volumes and forced ventilatory flows
Quanjer, P. H., Tammeling, G. J., Cotes, J. E., Pedersen, O. F., Peslin, R., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.005s1693 · Cited by 5,318
Rabe, K. F., Hurd, S., Anzueto, A., Barnes, P. J., Buist, S. A., Calverley, P., Fukuchi, Y., Jenkins, C., Rodriguez-Roisin, R., van Weel, C., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200703-456so · Cited by 4,925 · cited 1×
“All patients were diagnosed with COPD ranging in severity from mild to very severe according to the Global Initiative for Chronic Obstructive Lung Disease (or GOLD) (stages I to IV) [13].”
Method(1993) · PubMed · Cited by 3,827
Development and first validation of the COPD Assessment Test
Jones, P. W., Harding, G., Berry, P., Wiklund, I., Chen, W.-H., & Kline Leidy, N. (2009) · European Respiratory Journal · doi:10.1183/09031936.00102509 · Cited by 3,198
Jones, P. W., Quirk, F. H., Baveystock, C. M., & Littlejohns, P. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/145.6.1321 · Cited by 3,035 · cited 1×
“Each score ranges from 0 (no impairment) to 100 (worst possible) [21].”
BackgroundATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
Bestall, J. C., Paul, E. A., Garrod, R., Garnham, R., Jones, P. W., & Wedzicha, J. A. (1999) · Thorax · doi:10.1136/thx.54.7.581 · Cited by 2,927
The St George's Respiratory Questionnaire
Jones, P. W., Quirk, F. H., & Baveystock, C. M. (1991) · Respiratory Medicine · doi:10.1016/s0954-6111(06)80166-6 · Cited by 2,683
Rabe, K. F. (2007) · American Journal of Respiratory and Critical Care Medicine · Cited by 2,567
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
Applying the right statistics: analyses of measurement studies
Bland, J. M., & Altman, D. G. (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.122 · Cited by 1,311
Six minute walking distance in healthy elderly subjects
Troosters, T., Gosselink, R., & Decramer, M. (1999) · European Respiratory Journal · doi:10.1034/j.1399-3003.1999.14b06.x · Cited by 1,042
Self-citationPhysical Activity Is the Strongest Predictor of All-Cause Mortality in Patients With COPD
Waschki, B., Kirsten, A., Holz, O., Müller, K.-C., Meyer, T., Watz, H., & Magnussen, H. (2011) · Chest · doi:10.1378/chest.10-2521 · Cited by 951
Normal standards for an incremental progressive cycle ergometer test.
Jones, N. L., Makrides, L., Hitchcock, C., Chypchar, T., & McCartney, N. (1985) · PubMed · doi:10.1164/arrd.1985.131.5.700 · Cited by 717
Physical activity in patients with COPD
Watz, H., Waschki, B., Meyer, T., & Magnussen, H. (2009) · European Respiratory Journal · doi:10.1183/09031936.00024608 · Cited by 684
Standardization of the measurement of transfer factor (diffusing capacity)
Cotes, J. E., Chinn, D. J., Quanjer, P. H., Roca, J., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.041s1693 · Cited by 680
From COPD to chronic systemic inflammatory syndrome?
Fabbri, L. M., & Rabe, K. F. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61383-x · Cited by 635
Garcia-Aymerich, J., Lange, P., Benet, M., Schnohr, P., & Antó, J. M. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200607-896oc · Cited by 509
Assessment of energy expenditure for physical activity using a triaxial accelerometer
BOUTEN, C. V., WESTERTERP, K. R., VERDUIN, M., & JANSSEN, J. D. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199412000-00016 · Cited by 451
Je, C., Dj, C., Ph, Q., et al. (1993) · PubMed · Cited by 424
Physical inactivity in patients with COPD, a controlled multi-center pilot-study
Troosters, T., Sciurba, F., Battaglia, S., Langer, D., Valluri, S. R., Martino, L., Benzo, R., Andre, D., Weisman, I., & Decramer, M. (2010) · Respiratory Medicine · doi:10.1016/j.rmed.2010.01.012 · Cited by 371 · cited 1×
“As such patients are less physically active and move more slowly than healthy subjects [10,11], the validity of these monitors to detect movement in these patients needs to be evaluated.”
BackgroundSelf-citationEstimating energy expenditure using accelerometers
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0307-5 · Cited by 366
Are Patients With COPD More Active After Pulmonary Rehabilitation?
Pitta, F., Troosters, T., Probst, V. S., Langer, D., Decramer, M., & Gosselink, R. (2008) · Chest · doi:10.1378/chest.07-2655 · Cited by 300
Self-citationDecramer, M., Rennard, S., Troosters, T., Mapel, D. W., Giardino, N., Mannino, D., Wouters, E., Sethi, S., & Cooper, C. B. (2008) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550802237531 · Cited by 295
Self-citationValidity of Physical Activity Intensity Predictions by ActiGraph, Actical, and RT3 Accelerometers
Rothney, M. P., Schaefer, E. V., Neumann, M. M., Choi, L., & Chen, K. Y. (2008) · Obesity · doi:10.1038/oby.2008.279 · Cited by 175
Behnke, M., Taube, C., Kirsten, D., Lehnigk, B., Jörres, R., & MAGNUSSEN, H. (2000) · Respiratory Medicine · doi:10.1053/rmed.2000.0949 · Cited by 167
Concurrent validity of a trunk tri-axial accelerometer system for gait analysis in older adults
Hartmann, A., Luzi, S., Murer, K., de Bie, R. A., & de Bruin, E. D. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2008.11.003 · Cited by 159
Actigraph Accelerometer Interinstrument Reliability during Free-Living in Adults
McClain, J. J., Sisson, S. B., & Tudor-Locke, C. E. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3180dc9954 · Cited by 157
Problematic Activities of Daily Life are Weakly Associated With Clinical Characteristics in COPD
Annegarn, J., Meijer, K., Passos, V. L., Stute, K., Wiechert, J., Savelberg, H. H. C. M., Schols, A. M. W. J., Wouters, E. F. �., & Spruit, M. A. (2011) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2011.01.002 · Cited by 152
Perfil do nível de atividade física na vida diária de pacientes portadores de DPOC no Brasil
Hernandes, N. A., Teixeira, D. D. C., Probst, V. S., Brunetto, A. F., Ramos, E. M. C., & Pitta, F. D. O. (2009) · Jornal Brasileiro de Pneumologia · doi:10.1590/s1806-37132009001000002 · Cited by 145
Activity Monitoring and Energy Expenditure in COPD Patients: A Validation Study
Patel, S. A., Benzo, R. P., Slivka, W. A., & Sciurba, F. C. (2007) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550701246658 · Cited by 144
Abel, M. G., Hannon, J. C., Sell, K. M., Lillie, T., Conlin, G., & Anderson, D. (2008) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h08-103 · Cited by 138
Measurement properties of the SenseWear armband in adults with chronic obstructive pulmonary disease
Hill, K., Dolmage, T. E., Woon, L., Goldstein, R., & Brooks, D. (2010) · Thorax · doi:10.1136/thx.2009.128702 · Cited by 135
Validation of two activity monitors in patients with COPD
Langer, D., Gosselink, R., Sena, R. D. S., Burtin, C., Decramer, M., & Troosters, T. (2009) · Thorax · doi:10.1136/thx.2008.112102 · Cited by 124
Self-citationPredicting Energy Expenditure of Physical Activity Using Hip- and Wrist-Worn Accelerometers
Chen, K. Y., Acra, S. A., Majchrzak, K. M., Donahue, C. L., Baker, L., Clemens, L. H., Sun, M., & Buchowski, M. S. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322641088 · Cited by 117
Daily Physical Activity in Patients with Chronic Obstructive Pulmonary Disease: A Systematic Review
Bossenbroek, L., Greef, M. H. G. D., Wempe, J. B., Krijnen, W. P., & ten Hacken, N. H. T. (2011) · COPD Journal of Chronic Obstructive Pulmonary Disease · doi:10.3109/15412555.2011.578601 · Cited by 112
Walking Activity Measured by Accelerometry During Respiratory Rehabilitation
Coronado, M., Janssens, J.-P., de Muralt, B., Terrier, P., Schütz, Y., & Fitting, J.-W. (2003) · Journal of Cardiopulmonary Rehabilitation · doi:10.1097/00008483-200309000-00006 · Cited by 107
Baarends, E. M., Schols, A. M. W. J., Westerterp, K. R., & Wouters, E. F. �. (1997) · Thorax · doi:10.1136/thx.52.9.780 · Cited by 94
Energy expenditure during daily activities as measured by two motion sensors in patients with COPD
Cavalheri, V., Donária, L., Ferreira, T., Finatti, M. E., Camillo, C. A., Ramos, E. M. C., & Pitta, F. D. O. (2011) · European Respiratory Journal · doi:10.1016/j.rmed.2011.01.004 · Cited by 85
Decreased mechanical efficiency in clinically stable patients with COPD
Baarends, E. M., Schols, A. M. W. J., Akkermans, M. A., & Wouters, E. F. �. (1997) · Thorax · doi:10.1136/thx.52.11.981 · Cited by 80
Preliminary evaluation of reliability and criterion validity of Actiwatch-Score
Gironda, R. J., Lloyd, J. D., Clark, M. E., & Walker, R. L. (2007) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2006.06.0058 · Cited by 67
Comparison of Lifecorder EX and ActiGraph accelerometers under free-living conditions
McClain, J. J., Craig, C. L., Sisson, S. B., & Tudor-Locke, C. E. (2007) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h07-060 · Cited by 55
Test–retest reliability of a portable monitor to assess energy expenditure
Brazeau, A., Karelis, A. D., Mignault, D., Lacroix, M.-J., Prud’homme, D., & RABASA-LHORET, R. P. R. (2011) · Applied Physiology Nutrition and Metabolism · doi:10.1139/h11-016 · Cited by 38
Høydal, K. L., Helgerud, J., Karlsen, T., Støylen, A., Steinshamn, S., & Hoff, J. (2007) · Scandinavian Cardiovascular Journal · doi:10.1080/14017430701601636 · Cited by 22
Interinstrument reliability of the RT3 accelerometer
Reneman, M. F., & Helmus, M. (2010) · International Journal of Rehabilitation Research · doi:10.1097/mrr.0b013e32832c1e73 · Cited by 18
Troosters, T., Weisman, I., Dobbels, F., Giardino, N., & Valluri, S. R. (2011) · The Open Respiratory Medicine Journal · doi:10.2174/1874306401105010001 · Cited by 18
Self-citation
Cited by
Assessment of Physical Activity and Energy Expenditure: An Overview of Objective Measures
Hills, A. P., Mokhtar, N., & Byrne, N. M. (2014) · Frontiers in Nutrition · doi:10.3389/fnut.2014.00005 · Cited by 575
An official European Respiratory Society statement on physical activity in COPD
Watz, H., Pitta, F., Rochester, C. L., Garcia-Aymerich, J., ZuWallack, R., Troosters, T., Vaes, A. W., Puhan, M. A., Jehn, M., Polkey, M. I., et al. (2014) · European Respiratory Journal · doi:10.1183/09031936.00046814 · Cited by 526
Self-citationMercer, K., Giangregorio, L., Schneider, E., Chilana, P., Li, M., & Grindrod, K. (2016) · JMIR mHealth and uHealth · doi:10.2196/mhealth.4225 · Cited by 419
Lobelo, F., Rohm Young, D., Sallis, R., Garber, M. D., Billinger, S. A., Duperly, J., Hutber, A., Pate, R. R., Thomas, R. J., Widlansky, M. E., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000559 · Cited by 402
Validity of physical activity monitors during daily life in patients with COPD
Rabinovich, R. A., Louvaris, Z., Raste, Y., Langer, D., Van Remoortel, H., Giavedoni, S., Burtin, C., Regueiro, E. M. G., Vogiatzis, I., Hopkinson, N. S., et al. (2013) · European Respiratory Journal · doi:10.1183/09031936.00134312 · Cited by 293
Self-citation
Metadata
- Authors
- Van Remoortel, H., Raste, Y., Louvaris, Z., Giavedoni, S., Burtin, C., Langer, D., Wilson, F., Rabinovich, R., Vogiatzis, I., Hopkinson, N. S., Troosters, T., & on behalf of PROactive consortium
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2012-06-20
- Volume
- 7
- Issue
- 6
- Pages
- e39198
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W1976667296
- Cited by
- 323
- References
- 50
- FWCI
- 22.06
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.