The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Methods for Applying Accurate Digital PCR Analysis on Low Copy DNA Samples
Open accessAbstract
Digital PCR (dPCR) is a highly accurate molecular approach, capable of precise measurements, offering a number of unique opportunities. However, in its current format dPCR can be limited by the amount of sample that can be analysed and consequently additional considerations such as performing multiplex reactions or pre-amplification can be considered. This study investigated the impact of duplexing and pre-amplification on dPCR analysis by using three different assays targeting a model template (a portion of the Arabidopsis thaliana alcohol dehydrogenase gene). We also investigated the impact of different template types (linearised plasmid clone and more complex genomic DNA) on measurement precision using dPCR. We were able to demonstrate that duplex dPCR can provide a more precise measurement than uniplex dPCR, while applying pre-amplification or varying template type can significantly decrease the precision of dPCR. Furthermore, we also demonstrate that the pre-amplification step can introduce measurement bias that is not consistent between experiments for a sample or assay and so could not be compensated for during the analysis of this data set. We also describe a model for estimating the prevalence of molecular dropout and identify this as a source of dPCR imprecision. Our data have demonstrated that the precision afforded by dPCR at low sample concentration can exceed that of the same template post pre-amplification thereby negating the need for this additional step. Our findings also highlight the technical differences between different templates types containing the same sequence that must be considered if plasmid DNA is to be used to assess or control for more complex templates like genomic DNA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments
Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G. L., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112797 · Cited by 16,303
Self-citationComprehensive human genome amplification using multiple displacement amplification
Dean, F. B., Hosono, S., Fang, L., Wu, X., Faruqi, A. F., Bray-Ward, P., Sun, Z., Zong, Q., Du, Y., Du, J., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.082089499 · Cited by 1,467
Multiplex PCR: Optimization and Application in Diagnostic Virology
Elnifro, E. M., Ashshi, A. M., Cooper, R. J., & Klapper, P. E. (2000) · Clinical Microbiology Reviews · doi:10.1128/cmr.13.4.559-570.2000 · Cited by 964
Whale, A. S., Huggett, J. F., Cowen, S., Speirs, V., Shaw, J., Ellison, S., Foy, C. A., & Scott, D. J. (2012) · Nucleic Acids Research · doi:10.1093/nar/gks203 · Cited by 453 · cited 7×
“might explain why it is more precise than qPCR [2].”
BackgroundMethodInfluentialSelf-citationDube, S., Qin, J., & Ramakrishnan, R. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002876 · Cited by 302
Differential susceptibility of PCR reactions to inhibitors: an important and unrecognised phenomenon
Huggett, J. F., Novak, T., Garson, J. A., Green, C., Morris-Jones, S. D., Miller, R. F., & Zumla, A. (2008) · BMC Research Notes · doi:10.1186/1756-0500-1-70 · Cited by 250 · cited 1×
“Other sources of error in dPCR that may also contribute to the variability in the measurement include chamber volume variation and sample distribution within a panel [38], degradation of the template due to prolonged periods of heating [39,40], PCR inhibitors that affect one assay more than the other [3] as well as po…”
BackgroundSelf-citationBhat, S., Herrmann, J., Armishaw, P., Corbisier, P., & Emslie, K. R. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2729-5 · Cited by 218
Biomarkers for early detection of breast cancer: What, when, and where?
LEVENSON, V (2007) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2007.01.017 · Cited by 131 · cited 1×
“Samples where low quantity template is commonplace, for example in cell free DNA analysis [31,32], can benefit from duplexing as it reduces the number of separate PCR reactions required [25] and thus amount of sample used.”
BackgroundApplicability of RNA standards for evaluating RT-qPCR assays and platforms
Devonshire, A. S., Elaswarapu, R., & Foy, C. A. (2011) · BMC Genomics · doi:10.1186/1471-2164-12-118 · Cited by 42
Self-citation
Cited by
Huggett, J. F., Foy, C. A., Benes, V., Emslie, K., Garson, J. A., Haynes, R., Hellemans, J., Kubista, M., Mueller, R. D., Nolan, T., et al. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.206375 · Cited by 859
Self-citationGuidelines for Validation of Next-Generation Sequencing–Based Oncology Panels
Jennings, L. J., Arcila, M. E., Corless, C., Kamel-Reid, S., Lubin, I. M., Pfeifer, J., Temple-Smolkin, R. L., Voelkerding, K. V., & Nikiforova, M. N. (2017) · The Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2017.01.011 · Cited by 743
Quan, P.-L., Sauzade, M., & Brouzes, E. (2018) · Sensors · doi:10.3390/s18041271 · Cited by 664
The dMIQE Group, Whale, A. S., De Spiegelaere, W., Trypsteen, W., Nour, A. A., Bae, Y.-K., Benes, V., Burke, D., Cleveland, M., Corbisier, P., et al. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvaa125 · Cited by 516
Self-citationConsiderations for Digital PCR as an Accurate Molecular Diagnostic Tool
Huggett, J. F., Cowen, S., & Foy, C. A. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2014.221366 · Cited by 444
Self-citation
Metadata
- Authors
- Whale, A. S., Cowen, S., Foy, C. A., & Huggett, J. F.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-03-05
- Volume
- 8
- Issue
- 3
- Pages
- e58177
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2047043493
- Cited by
- 160
- References
- 9
- FWCI
- 6.05
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Methods for Applying Accurate Digital PCR Analysis on Low Copy DNA Samples. https://app.cochat.ai/papers/10.1371/journal.pone.0058177
- The paper
- Whale, A. S., Cowen, S., Foy, C. A., & Huggett, J. F. (2013). Methods for Applying Accurate Digital PCR Analysis on Low Copy DNA Samples. PLoS ONE. https://doi.org/10.1371/journal.pone.0058177
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.