Specific In Vivo Labeling of Tyrosinated α-Tubulin and Measurement of Microtubule Dynamics Using a GFP Tagged, Cytoplasmically Expressed Recombinant Antibody
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
GFP-tagged proteins are used extensively as biosensors for protein localization and function, but the GFP moiety can interfere with protein properties. An alternative is to indirectly label proteins using intracellular recombinant antibodies (scFvs), but most antibody fragments are insoluble in the reducing environment of the cytosol. From a synthetic hyperstable human scFv library we isolated an anti-tubulin scFv, 2G4, which is soluble in mammalian cells when expressed as a GFP-fusion protein. Here we report the use of this GFP-tagged scFv to label microtubules in fixed and living cells. We found that 2G4-GFP localized uniformly along microtubules and did not disrupt binding of EB1, a protein that binds microtubule ends and serves as a platform for binding by a complex of proteins regulating MT polymerization. TOGp and CLIP-170 also bound microtubule ends in cells expressing 2G4-GFP. Microtubule dynamic instability, measured by tracking 2G4-GFP labeled microtubules, was nearly identical to that measured in cells expressing GFP-α-tubulin. Fluorescence recovery after photobleaching demonstrated that 2G4-GFP turns over rapidly on microtubules, similar to the turnover rates of fluorescently tagged microtubule-associated proteins. These data indicate that 2G4-GFP binds relatively weakly to microtubules, and this conclusion was confirmed in vitro. Purified 2G4 partially co-pelleted with microtubules, but a significant fraction remained in the soluble fraction, while a second anti-tubulin scFv, 2F12, was almost completely co-pelleted with microtubules. In cells, 2G4-GFP localized to most microtubules, but did not co-localize with those composed of detyrosinated α-tubulin, a post-translational modification associated with non-dynamic, more stable microtubules. Immunoblots probing bacterially expressed tubulins confirmed that 2G4 recognized α-tubulin and required tubulin's C-terminal tyrosine residue for binding. Thus, a recombinant antibody with weak affinity for its substrate can be used as a specific intracellular biosensor that can differentiate between unmodified and post-translationally modified forms of a protein.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tracking the ends: a dynamic protein network controls the fate of microtubule tips
Akhmanova, A., & Steinmetz, M. O. (2008) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2369 · Cited by 1,047 · cited 2×
“directly to microtubule plus ends, while several other plus end binding proteins are at least partially dependent on EB1 for their localization to microtubules [29,30].”
BackgroundMicrotubule Acetylation Promotes Kinesin-1 Binding and Transport
Reed, N. A., Cai, D., Blasius, T. L., Jih, G. T., Meyhofer, E., Gaertig, J., & Verhey, K. J. (2006) · Current Biology · doi:10.1016/j.cub.2006.09.014 · Cited by 919
Traffic control: regulation of kinesin motors
Verhey, K. J., & Hammond, J. W. (2009) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2782 · Cited by 546
Microtubules and signal transduction
Gundersen, G. G., & Cook, T. A. (1999) · Current Opinion in Cell Biology · doi:10.1016/s0955-0674(99)80010-6 · Cited by 407 · cited 2×
“Heterodimers of a and ß tubulin polymerize to form microtubules, polymers responsible for a number of cellular functions including chromosome movement in mitosis, vesicle transport, intracellular organization and as scaffolds for components of signal transduction pathways [8,9,10].”
BackgroundTau interaction with microtubules in vivo
Samsonov, A., Yu, J.-Z., Rasenick, M., & Popov, S. V. (2004) · Journal of Cell Science · doi:10.1242/jcs.01531 · Cited by 129
Dynamic behavior of GFP-CLIP-170 reveals fast protein turnover on microtubule plus ends
Dragestein, K. A., van Cappellen, W. A., van Haren, J., Tsibidis, G. D., Akhmanova, A., Knoch, T. A., Grosveld, F., & Galjart, N. (2008) · The Journal of Cell Biology · doi:10.1083/jcb.200707203 · Cited by 116
Cited by
Yue, Y., Hotta, T., Higaki, T., Verhey, K. J., & Ohi, R. (2023) · Current Biology · doi:10.1016/j.cub.2023.07.062 · Cited by 39
Cellular cartography: Towards an atlas of the neuronal microtubule cytoskeleton
Iwanski, M. K., & Kapitein, L. C. (2023) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2023.1052245 · Cited by 38
Genetically encoded live-cell sensor for tyrosinated microtubules
Kesarwani, S., Lama, P., Chandra, A., Reddy, P. P., Jijumon, A. S., Bodakuntla, S., Rao, B. M., Janke, C., Das, R., & Sirajuddin, M. (2020) · Journal of Cell Biology · doi:10.1083/jcb.201912107 · Cited by 37
“Another study has reported the identification of a single-chain antibody (anti-tubulin singlechain variable fragment; scFv) against tyrosinated microtubules (Cassimeris et al., 2013).”
BackgroundGaetani, M. L., Pinto, I. C., Li, M., O’Connor, P., Giorgi-Coll, S., Tyreman, M., Rumary, K. L., Schouten, J. A., Davis, P., & Dixon, A. M. (2024) · Molecular Immunology · doi:10.1016/j.molimm.2023.12.008 · Cited by 3
Metadata
- Authors
- Cassimeris, L., Guglielmi, L., Denis, V., Larroque, C., & Martineau, P.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-03-28
- Volume
- 8
- Issue
- 3
- Pages
- e59812
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2030747981
- Cited by
- 19
- References
- 6
- FWCI
- 0.86
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Specific In Vivo Labeling of Tyrosinated α-Tubulin and Measurement of Microtubule Dynamics Using a GFP Tagged, Cytoplasmically Expressed Recombinant Antibody. https://app.cochat.ai/papers/10.1371/journal.pone.0059812
- The paper
- Cassimeris, L., Guglielmi, L., Denis, V., Larroque, C., & Martineau, P. (2013). Specific In Vivo Labeling of Tyrosinated α-Tubulin and Measurement of Microtubule Dynamics Using a GFP Tagged, Cytoplasmically Expressed Recombinant Antibody. PLoS ONE. https://doi.org/10.1371/journal.pone.0059812
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.