Using a Body-Fixed Sensor to Identify Subclinical Gait Difficulties in Older Adults with IADL Disability: Maximizing the Output of the Timed Up and Go
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The identification and documentation of subclinical gait impairments in older adults may facilitate the appropriate use of interventions for preventing or delaying mobility disability. We tested whether measures derived from a single body-fixed sensor worn during traditional Timed Up and Go (TUG) testing could identify subclinical gait impairments in community dwelling older adults without mobility disability. METHODS: We used data from 432 older adults without dementia (mean age 83.30 ± 7.04 yrs, 76.62% female) participating in the Rush Memory and Aging Project. The traditional TUG was conducted while subjects wore a body-fixed sensor. We derived measures of overall TUG performance and different subtasks including transitions (sit-to-stand, stand-to-sit), walking, and turning. Multivariate analysis was used to compare persons with and without mobility disability and to compare individuals with and without Instrumental Activities of Daily Living disability (IADL-disability), all of whom did not have mobility disability. RESULTS: As expected, individuals with mobility disability performed worse on all TUG subtasks (p<0.03), compared to those who had no mobility disability. Individuals without mobility disability but with IADL disability had difficulties with turns, had lower yaw amplitude (p<0.004) during turns, were slower (p<0.001), and had less consistent gait (p<0.02). CONCLUSIONS: A single body-worn sensor can be employed in the community-setting to complement conventional gait testing. It provides a wide range of quantitative gait measures that appear to help to identify subclinical gait impairments in older adults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
Restoring Voluntary Control of Locomotion after Paralyzing Spinal Cord Injury
van den Brand, R., Heutschi, J., Barraud, Q., DiGiovanna, J., Bartholdi, K., Huerlimann, M., Friedli, L., Vollenweider, I., Moraud, E. M., Duis, S., et al. (2012) · Science · doi:10.1126/science.1217416 · Cited by 767
iTUG, a Sensitive and Reliable Measure of Mobility
Salarian, A., Horak, F. B., Zampieri, C., Carlson-Kuhta, P., Nutt, J. G., & Aminian, K. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047606 · Cited by 489
Ambulatory monitoring of physical activities in patients with Parkinson’s disease
Salarian, A., Russmann, H., Vingerhoets, F. J. G., Burkhard, P. R., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.896591 · Cited by 217 · cited 1×
“, transitions [19–23] or turns [24], may be sensitive to specific gait and balance impairments that cannot be identified using only the TUG duration.”
BackgroundWeiss, A., Herman, T., Plotnik, M., Brozgol, M., Maidan, I., Giladi, N., Gurevich, T., & Hausdorff, J. M. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.10.015 · Cited by 207 · cited 1×
“The extraction of the AP measures is described elsewhere [10,11], and includes the duration of each transition as well as range and jerk measures, median and standard deviation values.”
MethodSelf-citationZampieri, C., Salarian, A., Carlson-Kuhta, P., Nutt, J. G., & Horak, F. B. (2011) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2010.08.001 · Cited by 103
Measurement of Multi-segment Foot Joint Angles During Gait Using a Wearable System
Rouhani, H., Favre, J., Crevoisier, X., & Aminian, K. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4006674 · Cited by 72
Bean, J. F., Kiely, D. K., LaRose, S., & Leveille, S. G. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.04.029 · Cited by 50 · cited 1×
“This has led to gaps in our knowledge with respect to the characterization of the full spectrum of gait impairments in older adults, especially among older more debilitated individuals, who are unable to participate in laboratory studies [38].”
Background
Cited by
Religious Orders Study and Rush Memory and Aging Project
Bennett, D. A., Buchman, A. S., Boyle, P. A., Barnes, L. L., Wilson, R. S., & Schneider, J. A. (2018) · Journal of Alzheimer's Disease · doi:10.3233/jad-179939 · Cited by 1,260
Self-citationFalls in Parkinson's disease: A complex and evolving picture
Fasano, A., Canning, C. G., Hausdorff, J. M., Lord, S., & Rochester, L. (2017) · Movement Disorders · doi:10.1002/mds.27195 · Cited by 363
Self-citationIncreasing fall risk awareness using wearables: a fall risk awareness protocol
Danielsen, A., Olofsen, H., & Bremdal, B. A. (2016) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2016.08.016 · Cited by 66
Pilot Study of the EncephaLog Smartphone Application for Gait Analysis
Tchelet, K., Stark-Inbar, A., & Yekutieli, Z. (2019) · Sensors · doi:10.3390/s19235179 · Cited by 27
Metadata
- Authors
- Weiss, A., Mirelman, A., Buchman, A. S., Bennett, D. A., & Hausdorff, J. M.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-07-29
- Volume
- 8
- Issue
- 7
- Pages
- e68885
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2142422748
- Cited by
- 82
- References
- 8
- FWCI
- 18.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Using a Body-Fixed Sensor to Identify Subclinical Gait Difficulties in Older Adults with IADL Disability: Maximizing the Output of the Timed Up and Go. https://app.cochat.ai/papers/10.1371/journal.pone.0068885
- The paper
- Weiss, A., Mirelman, A., Buchman, A. S., Bennett, D. A., & Hausdorff, J. M. (2013). Using a Body-Fixed Sensor to Identify Subclinical Gait Difficulties in Older Adults with IADL Disability: Maximizing the Output of the Timed Up and Go. PLoS ONE. https://doi.org/10.1371/journal.pone.0068885
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.