The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Fast QRS Detection with an Optimized Knowledge-Based Method: Evaluation on 11 Standard ECG Databases
Open accessAbstract
The current state-of-the-art in automatic QRS detection methods show high robustness and almost negligible error rates. In return, the methods are usually based on machine-learning approaches that require sufficient computational resources. However, simple-fast methods can also achieve high detection rates. There is a need to develop numerically efficient algorithms to accommodate the new trend towards battery-driven ECG devices and to analyze long-term recorded signals in a time-efficient manner. A typical QRS detection method has been reduced to a basic approach consisting of two moving averages that are calibrated by a knowledge base using only two parameters. In contrast to high-accuracy methods, the proposed method can be easily implemented in a digital filter design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Discrete-Time Signal Processing
Oppenheim, A. V., & Schafer, R. W. (1989) · Cited by 12,572
Global status report on noncommunicable diseases 2010.
Alwan, A. (2011) · Cited by 8,494
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
The impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,812
A Wavelet-Based ECG Delineator: Evaluation on Standard Databases
Martinez, J. P., Almeida, R., Olmos, S., Rocha, A. P., & Laguna, P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821031 · Cited by 1,605
Detection of ECG characteristic points using wavelet transforms
Li, C., Zheng, C., & Tai, C. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362922 · Cited by 1,597
Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database
Hamilton, P. S., & Tompkins, W. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325695 · Cited by 1,142
A comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043 · cited 1×
“1 (a)), which are known to be a major disturbance [6].”
BackgroundAdvanced Methods And Tools for ECG Data Analysis
Clifford, G. D., Azuaje, F. J., & McSharry, P. (2006) · Cited by 808
Age-related alterations in the fractal scaling of cardiac interbeat interval dynamics
Iyengar, N., Peng, C. K., Morin, R., Goldberger, A. L., & Lipsitz, L. A. (1996) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1996.271.4.r1078 · Cited by 702
Simple electrocardiographic markers for the prediction of paroxysmal idiopathic atrial fibrillation
Dilaveris, P. E., Gialafos, E. J., Sideris, S. K., Theopistou, A. M., Andrikopoulos, G. K., Kyriakidis, M., Gialafos, J. E., & Toutouzas, P. K. (1998) · American Heart Journal · doi:10.1016/s0002-8703(98)70030-4 · Cited by 697
Laguna, P., Mark, R. G., Goldberg, A., & Moody, G. B. (2002) · Computers in Cardiology 1997 · doi:10.1109/cic.1997.648140 · Cited by 606
Neural-network-based adaptive matched filtering for QRS detection
Xue, Q., Hu, Y. H., & Tompkins, W. J. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126604 · Cited by 423
Analysis of First-Derivative Based QRS Detection Algorithms
Arzeno, N. M., Deng, Z.-D., & Poon, C.-S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912658 · Cited by 413
Heart Disease: A Textbook of Cardiovascular Medicine. 7th Edition
Bonow, R. O., Zipes, D. P., Libby, P., Ro, B., & Braunwald, E. (2004) · Cited by 397
Hamilton, P. (2003) · Computers in Cardiology · doi:10.1109/cic.2002.1166717 · Cited by 380
Using wavelet transforms for ECG characterization. An on-line digital signal processing system
Sahambi, J. S., Tandon, S. N., & Bhatt, R. K. P. (1997) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.566158 · Cited by 357
A real-time QRS detection method based on moving-averaging incorporating with wavelet denoising
Chen, S.-W., Chen, H.-C., & Chan, H.-L. (2006) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2005.11.012 · Cited by 264
A comparison of two methods for measuring the signal to noise ratio on MR images
Firbank, M. J., Coulthard, A., Harrison, R. M., & Williams, E. D. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/12/403 · Cited by 256
A new QRS detection algorithm based on the Hilbert transform
Benitez, D. S., Gaydecki, P. A., Zaidi, A., & Fitzpatrick, A. P. (2002) · Computers in Cardiology 2000. Vol.27 (Cat. 00CH37163) · doi:10.1109/cic.2000.898536 · Cited by 198
ECG Feature Extraction Based on Multiresolution Wavelet Transform
Mahmoodabadi, S. Z., Ahmadian, A., Abolhasani, M. D., Eslami, M., & Bidgoli, J. H. (2005) · 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference · doi:10.1109/iembs.2005.1615314 · Cited by 184
Thakor, N. V., Webster, J. G., & Tompkins, W. J. (1983) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478504 · Cited by 150
FREQUENCY BANDS EFFECTS ON QRS DETECTION
Elgendi, M., Jonkman, M., & Boer, F. D. (2010) · International Conference on Bio-inspired Systems and Signal Processing · doi:10.5220/0002742704280431 · Cited by 147
Self-citationA new mathematical based QRS detector using continuous wavelet transform
Ghaffari, A., Golbayani, H., & Ghasemi, M. (2007) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2007.10.005 · Cited by 147
Silva, I., Moody, G. B., & Celi, L. A. (2011) · Cited by 125
A moving average based filtering system with its application to real-time QRS detection
Chen, H., & Chen, S.-W. (2003) · Computers in cardiology · doi:10.1109/cic.2003.1291223 · Cited by 123
A robust-digital QRS-detection algorithm for arrhythmia monitoring
Ligtenberg, A., & Kunt, M. (1983) · Computers and Biomedical Research · doi:10.1016/0010-4809(83)90027-7 · Cited by 96
Moody, G. B. (2005) · Computers in cardiology · doi:10.1109/cic.2004.1442881 · Cited by 92
The Physionet/Computers in Cardiology challenge 2008: T-wave alternans
Moody, G. B. (2008) · Computers in cardiology · doi:10.1109/cic.2008.4749089 · Cited by 91
Development of QRS detection algorithm designed for wearable cardiorespiratory system
Adnane, M., Jiang, Z., & Choi, S. (2008) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2008.07.010 · Cited by 90
A QRS complex detection algorithm using electrocardiogram leads
Moraes, J. C. T. D. B., de Freitas, M. M. D. B., Vilani, F. N., & Costa, E. V. (2003) · Computers in cardiology · doi:10.1109/cic.2002.1166743 · Cited by 72
A simple real-time QRS detection algorithm
Lee, J., Jeong, K., Yoon, J., & Lee, M. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.647473 · Cited by 69
A novel approach in R peak detection using Hybrid Complex Wavelet (HCW)
Fard, P. J. M., Moradi, M. H., & Tajvidi, M. R. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2006.11.236 · Cited by 62
Automatic Detection of ECG Ventricular Activity Waves using Continuous Spline Wavelet Transform
Alvarado-Serrano, C., Arregui, J., Ramos, J. M., & Pallas-Areny, R. (2005) · National Conference on Electrical and Electronics Engineering (ELECO) · doi:10.1109/iceee.2005.1529605 · Cited by 48
Towards real time QRS detection: A fast method using minimal pre-processing
Darrington, J. (2006) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2006.08.002 · Cited by 33
Improved QRS Detection Algorithm using Dynamic Thresholds
Elgendi, M., Jonkman, M., & Boer, F. D. (2009) · CDU eSpace Institutional Repository (Charles Darwin University) · Cited by 23
Self-citationA Robust QRS Complex Detection Algorithm Using Dynamic Thresholds
Elgendi, M., Mahalingam, S., Jonkman, M., & Boer, F. D. (2008) · Computer Science and its Applications · doi:10.1109/csa.2008.16 · Cited by 22
Self-citation
Cited by
Review of noise removal techniques in ECG signals
Chatterjee, S., Thakur, R. S., Yadav, R. N., Gupta, L., & Raghuvanshi, D. K. (2020) · IET Signal Processing · doi:10.1049/iet-spr.2020.0104 · Cited by 333
Elgendi, M., Norton, I., Brearley, M., Abbott, D., & Schuurmans, D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0076585 · Cited by 276
Self-citationBrain–heart interactions reveal consciousness in noncommunicating patients
Raimondo, F., Rohaut, B., Demertzi, A., Valente, M., Engemann, D. A., Salti, M., Fernandez Slezak, D., Naccache, L., & Sitt, J. D. (2017) · Annals of Neurology · doi:10.1002/ana.25045 · Cited by 106
Metadata
- Authors
- Elgendi, M.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-09-16
- Volume
- 8
- Issue
- 9
- Pages
- e73557
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2080883481
- Cited by
- 264
- References
- 38
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.