The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Evaluation of Digital PCR for Absolute RNA Quantification
Open accessAbstract
Gene expression measurements detailing mRNA quantities are widely employed in molecular biology and are increasingly important in diagnostic fields. Reverse transcription (RT), necessary for generating complementary DNA, can be both inefficient and imprecise, but remains a quintessential RNA analysis tool using qPCR. This study developed a Transcriptomic Calibration Material and assessed the RT reaction using digital (d)PCR for RNA measurement. While many studies characterise dPCR capabilities for DNA quantification, less work has been performed investigating similar parameters using RT-dPCR for RNA analysis. RT-dPCR measurement using three, one-step RT-qPCR kits was evaluated using single and multiplex formats when measuring endogenous and synthetic RNAs. The best performing kit was compared to UV quantification and sensitivity and technical reproducibility investigated. Our results demonstrate assay and kit dependent RT-dPCR measurements differed significantly compared to UV quantification. Different values were reported by different kits for each target, despite evaluation of identical samples using the same instrument. RT-dPCR did not display the strong inter-assay agreement previously described when analysing DNA. This study demonstrates that, as with DNA measurement, RT-dPCR is capable of accurate quantification of low copy RNA targets, but the results are both kit and target dependent supporting the need for calibration controls.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments
Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G. L., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112797 · Cited by 16,303
Self-citationMfold web server for nucleic acid folding and hybridization prediction
Zuker, M. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg595 · Cited by 13,404
Vogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770 · cited 1×
“Molecules are isolated by limiting dilution and partitioning, before being individually amplified by PCR [7,9].”
Huggett, J. F., Foy, C. A., Benes, V., Emslie, K., Garson, J. A., Haynes, R., Hellemans, J., Kubista, M., Mueller, R. D., Nolan, T., et al. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.206375 · Cited by 859 · cited 3×
“This may or may not give an accurate estimate for the original concentration of the RNA molecules of interest [30].”
BackgroundMethodSelf-citationWhale, A. S., Huggett, J. F., Cowen, S., Speirs, V., Shaw, J., Ellison, S., Foy, C. A., & Scott, D. J. (2012) · Nucleic Acids Research · doi:10.1093/nar/gks203 · Cited by 453 · cited 1×
“Much work has already been done to meticulously evaluate this technique for DNA molecular measurement [3,4,5,6,7,8].”
BackgroundSelf-citationProperties of the Reverse Transcription Reaction in mRNA Quantification
Ståhlberg, A., Håkansson, J., Xian, X., Semb, H., & Kubista, M. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.026161 · Cited by 409 · cited 1×
“Not only have we shown here the potential for RT sensitivity and variability to affect dPCR estimation, as previously reported when using qPCR [1,31], but our previous studies have shown similar disparity between dPCR and UV valuation when measuring DNA targets [7], suggesting the PCR step in the RT-dPCR may also cont…”
ResultEvaluation of digital PCR for absolute DNA quantification
Sanders, R., Huggett, J. F., Bushell, C. A., Cowen, S., Scott, D. J., & Foy, C. A. (2011) · Analytical Chemistry · doi:10.1021/ac103230c · Cited by 338 · cited 7×
“While for RNA measurement the precision of the RT-dPCR technique is high, it nonetheless introduces increased variability into the measurement value than dPCR alone [7].”
BackgroundMethodResultInfluentialSelf-citationDube, S., Qin, J., & Ramakrishnan, R. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002876 · Cited by 302
Comparison of Reverse Transcriptases in Gene Expression Analysis
Ståhlberg, A., Kubista, M., & Pfaffl, M. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.035469 · Cited by 240
Bhat, S., Herrmann, J., Armishaw, P., Corbisier, P., & Emslie, K. R. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2729-5 · Cited by 218 · cited 1×
“Much work has already been done to meticulously evaluate this technique for DNA molecular measurement [3,4,5,6,7,8].”
Background
Cited by
Choi, H. M. T., Schwarzkopf, M., Fornace, M. E., Acharya, A., Artavanis, G., Stegmaier, J., Cunha, A., & Pierce, N. A. (2018) · Development · doi:10.1242/dev.165753 · Cited by 1,495
The dMIQE Group, Whale, A. S., De Spiegelaere, W., Trypsteen, W., Nour, A. A., Bae, Y.-K., Benes, V., Burke, D., Cleveland, M., Corbisier, P., et al. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvaa125 · Cited by 516
Self-citationddPCR: a more accurate tool for SARS-CoV-2 detection in low viral load specimens
Suo, T., Liu, X., Feng, J., Guo, M., Hu, W., Guo, D., Ullah, H., Yang, Y., Zhang, Q., Wang, X., et al. (2020) · Emerging Microbes & Infections · doi:10.1080/22221751.2020.1772678 · Cited by 450
Considerations for Digital PCR as an Accurate Molecular Diagnostic Tool
Huggett, J. F., Cowen, S., & Foy, C. A. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2014.221366 · Cited by 444
Self-citationDroplet digital PCR of viral DNA/RNA, current progress, challenges, and future perspectives
Kojabad, A. A., Farzanehpour, M., Galeh, H. E. G., Dorostkar, R., Jafarpour, A., Bolandian, M., & Nodooshan, M. M. (2021) · Journal of Medical Virology · doi:10.1002/jmv.26846 · Cited by 297
Polymerase chain reaction in microfluidic devices
Ahrberg, C. D., Manz, A., & Chung, B. G. (2016) · Lab on a Chip · doi:10.1039/c6lc00984k · Cited by 283
Applications of Digital PCR for Clinical Microbiology
Kuypers, J., & Jerome, K. R. (2017) · Journal of Clinical Microbiology · doi:10.1128/jcm.00211-17 · Cited by 280
Bustin, S., & Nolan, T. (2017) · European Journal of Clinical Investigation · doi:10.1111/eci.12801 · Cited by 113
Metadata
- Authors
- Sanders, R., Mason, D. J., Foy, C. A., & Huggett, J. F.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-09-20
- Volume
- 8
- Issue
- 9
- Pages
- e75296
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2140755317
- Cited by
- 174
- References
- 12
- FWCI
- 5.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.