Configuring a Powered Knee and Ankle Prosthesis for Transfemoral Amputees within Five Specific Ambulation Modes
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Lower limb prostheses that can generate net positive mechanical work may restore more ambulation modes to amputees. However, configuration of these devices imposes an additional burden on clinicians relative to conventional prostheses; devices for transfemoral amputees that require configuration of both a knee and an ankle joint are especially challenging. In this paper, we present an approach to configuring such powered devices. We developed modified intrinsic control strategies--which mimic the behavior of biological joints, depend on instantaneous loads within the prosthesis, or set impedance based on values from previous states, as well as a set of starting configuration parameters. We developed tables that include a list of desired clinical gait kinematics and the parameter modifications necessary to alter them. Our approach was implemented for a powered knee and ankle prosthesis in five ambulation modes (level-ground walking, ramp ascent/descent, and stair ascent/descent). The strategies and set of starting configuration parameters were developed using data from three individuals with unilateral transfemoral amputations who had previous experience using the device; this approach was then tested on three novice unilateral transfemoral amputees. Only 17% of the total number of parameters (i.e., 24 of the 140) had to be independently adjusted for each novice user to achieve all five ambulation modes and the initial accommodation period (i.e., time to configure the device for all modes) was reduced by 56%, to 5 hours or less. This approach and subsequent reduction in configuration time may help translate powered prostheses into a viable clinical option where amputees can more quickly appreciate the benefits such devices can provide.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050
Ziegler-Graham, K., MacKenzie, E. J., Ephraim, P. L., Travison, T. G., & Brookmeyer, R. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.005 · Cited by 2,816 · cited 1×
“As lower limb prosthetic options advance, so too does the promise of increased mobility for the more than 600,000 individuals in the United States who live with a major lower limb amputation [1].”
BackgroundStair ascent and descent at different inclinations
Riener, R., Rabuffetti, M., & Frigo, C. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00162-x · Cited by 744
An integrated biomechanical analysis of normal stair ascent and descent
McFadyen, B. J., & Winter, D. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90282-5 · Cited by 693 · cited 2×
“Across all modes, the resulting kinematic and kinetic data from the prosthesis side were similar in both amplitude and timing to non-amputee gait [21,23] and to that of one transfemoral amputee whose powered knee and ankle prosthesis was empirically tuned [5,12,16].”
MethodDesign and Control of a Powered Transfemoral Prosthesis
Sup, F., Bohara, A., & Goldfarb, M. (2008) · The International Journal of Robotics Research · doi:10.1177/0278364907084588 · Cited by 586 · cited 2×
“The powered prosthesis was empirically tuned for the three experienced users [7].”
BackgroundGailey, R. S., Roach, K. E., Applegate, E. B., Cho, B., Cunniffe, B., Licht, S., Maguire, M., & Nash, M. S. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/ampr.2002.32309 · Cited by 585
Energy Generation and Absorption at the Ankle and Knee during Fast, Natural, and Slow Cadences
WINTER, D. A. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198305000-00021 · Cited by 579 · cited 2×
“Across all modes, the resulting kinematic and kinetic data from the prosthesis side were similar in both amplitude and timing to non-amputee gait [21,23] and to that of one transfemoral amputee whose powered knee and ankle prosthesis was empirically tuned [5,12,16].”
BackgroundPowered ankle-foot prosthesis to assist level-ground and stair-descent gaits
Au, S., Berniker, M., & Herr, H. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.03.006 · Cited by 487
Powered Ankle--Foot Prosthesis Improves Walking Metabolic Economy
Au, S. K., Weber, J., & Herr, H. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2008747 · Cited by 487 · cited 3×
“Earlier research with the BiOM Ankle System describes adjusting ankle stiffness, damping, and power delivery such that the angle of the prosthetic ankle at toe off and net positive mechanical work matched average biological ankle data [15].”
BackgroundEnergy expenditure and biomechanical characteristics of lower limb amputee gait:
Schmalz, T., Blumentritt, S., & Jarasch, R. (2002) · Gait & Posture · doi:10.1016/s0966-6362(02)00008-5 · Cited by 428 · cited 1×
“Although clinical comparisons of these devices with their predecessors (non-microprocessor-controlled passive knees) have been mixed, microprocessor-controlled passive devices have been shown to reduce energy expenditure during walking [2].”
BackgroundControl of a Powered Ankle–Foot Prosthesis Based on a Neuromuscular Model
Eilenberg, M. F., Geyer, H., & Herr, H. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039620 · Cited by 419 · cited 1×
“Powered devices use a variety of control methods such as finite state machines in combination with an impedance-based model [7], artificial reflexes [8], or complementary motion estimation [9].”
BackgroundBionic ankle–foot prosthesis normalizes walking gait for persons with leg amputation
Herr, H. M., & Grabowski, A. M. (2012) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2011.1194 · Cited by 391 · cited 1×
“Earlier research with the BiOM Ankle System describes adjusting ankle stiffness, damping, and power delivery such that the angle of the prosthetic ankle at toe off and net positive mechanical work matched average biological ankle data [15].”
MethodPreliminary Evaluations of a Self-Contained Anthropomorphic Transfemoral Prosthesis
Sup, F., Varol, H. A., Mitchell, J., Withrow, T. J., & Goldfarb, M. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2009.2032688 · Cited by 298 · cited 10×
“A few powered prostheses, such as the Ossur Power Knee [3] and BiOM Ankle System [4], are currently on the market while others are in development [5,6].”
BackgroundMethodResultInfluentialUpslope Walking With a Powered Knee and Ankle Prosthesis: Initial Results With an Amputee Subject
Sup, F., Varol, H. A., & Goldfarb, M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2087360 · Cited by 283 · cited 2×
“Across all modes, the resulting kinematic and kinetic data from the prosthesis side were similar in both amplitude and timing to non-amputee gait [21,23] and to that of one transfemoral amputee whose powered knee and ankle prosthesis was empirically tuned [5,12,16].”
Reference Trajectory Generation for Rehabilitation Robots: Complementary Limb Motion Estimation
Vallery, H., van Asseldonk, E. H. F., Buss, M., & van der Kooij, H. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008278 · Cited by 228 · cited 1×
“Powered devices use a variety of control methods such as finite state machines in combination with an impedance-based model [7], artificial reflexes [8], or complementary motion estimation [9].”
BackgroundControl of Stair Ascent and Descent With a Powered Transfemoral Prosthesis
Lawson, B. E., Varol, H. A., Huff, A., Erdemir, E., & Goldfarb, M. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2225640 · Cited by 206 · cited 2×
“Across all modes, the resulting kinematic and kinetic data from the prosthesis side were similar in both amplitude and timing to non-amputee gait [21,23] and to that of one transfemoral amputee whose powered knee and ankle prosthesis was empirically tuned [5,12,16].”
Bellman, R. D., Holgate, M. A., & Sugar, T. G. (2008) · 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics · doi:10.1109/biorob.2008.4762887 · Cited by 163 · cited 1×
“A few powered prostheses, such as the Ossur Power Knee [3] and BiOM Ankle System [4], are currently on the market while others are in development [5,6].”
BackgroundSelf-contained powered knee and ankle prosthesis: Initial evaluation on a transfemoral amputee
Sup, F. C., Varol, H. A., Mitchell, J. E., Withrow, T. J., & Goldfarb, M. T. (2009) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209625 · Cited by 134 · cited 1×
“With the use of modified stance phase intrinsic control strategies compared with [11] and tuning tables that link desired changes in kinematics to specific parameter changes, only 24 of the 140 configuration parameters across five modes of ambulation needed tuning for novice users.”
MethodRealizing the Promise of Robotic Leg Prostheses
Goldfarb, M., Lawson, B. E., & Shultz, A. H. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007312 · Cited by 112 · cited 1×
“Since powered microprocessor-controlled prostheses use motors to provide virtual stiffness and damping characteristics in all phases of the gait cycle, their configuration is inherently more complex—configuration possibilities for some of these devices are essentially endless [14].”
BackgroundEstimation of human ankle impedance during walking using the perturberator robot
Rouse, E. J., Hargrove, L. J., Perreault, E. J., & Kuiken, T. (2012) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290842 · Cited by 44 · cited 2×
“Ankle stiffness, kankle, was modified as a function of ankle angle based on studies designed to identify the ankle stiffness of able-bodied subjects during walking [17]:”
BackgroundMethodSelf-citation
Research works printed but not linked: 2
- JM Aldridge, 2012, Stair ascent kinematics and kinetics with a powered lower leg system following transtibial amputation, Gait Posture, 36, 291, 10.1016/j.gaitpost.2012.03.013 · doi:10.1016/j.gaitpost.2012.03.013
- D Datta, 1996, Timed walking test – an all-embracing outcome measure for lower-limb amputees?, Clin Rehabil, 10, 227, 10.1177/026921559601000307 · doi:10.1177/026921559601000307
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationQuintero, D., Villarreal, D. J., Lambert, D. J., Kapp, S., & Gregg, R. D. (2018) · IEEE Transactions on Robotics · doi:10.1109/tro.2018.2794536 · Cited by 252
“to the user’s weight and preferred gait [14].”
Design and clinical implementation of an open-source bionic leg
Azocar, A. F., Mooney, L. M., Duval, J.-F., Simon, A. M., Hargrove, L. J., & Rouse, E. J. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00619-3 · Cited by 223
Self-citationDesign and Validation of a Powered Knee–Ankle Prosthesis With High-Torque, Low-Impedance Actuators
Elery, T., Rezazadeh, S., Nesler, C., & Gregg, R. D. (2020) · IEEE Transactions on Robotics · doi:10.1109/tro.2020.3005533 · Cited by 181
“to achieve the desired performance, since they are not known beforehand and change from one subject to another [35].”
Background
Metadata
- Authors
- Simon, A. M., Ingraham, K. A., Fey, N. P., Finucane, S. B., Lipschutz, R. D., Young, A. J., & Hargrove, L. J.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2014-06-10
- Volume
- 9
- Issue
- 6
- Pages
- e99387
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2117608991
- Cited by
- 207
- References
- 20
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.