Technical Factors Involved in the Measurement of Circulating MicroRNA Biomarkers for the Detection of Colorectal Neoplasia
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Circulating miRNAs are emerging as promising blood-based biomarkers for colorectal and other human cancers; however, technical factors that confound the development of these assays remain poorly understood and present a clinical challenge. The aim of this study was to systematically evaluate the effects of factors that may interfere with the accurate measurement of circulating miRNAs for clinical purposes. METHODS: Blood samples from 53 subjects, including routinely drawn serum samples, matched plasma from 30 subjects, and matched serum samples drawn before and after bowel preparation for colonoscopy from 29 subjects were collected. Additionally, 38 serum specimens stored in the clinical laboratory for seven days were used to test the stability of miRNAs. Hemolysis controls with serial dilutions of hemoglobin were prepared. RNA was extracted from serum, plasma or hemolyzed controls with spiked-in cel-miR-39, and levels of miR-21, miR-29a, miR-125b and miR-16 were examined by real-time RT-PCR. Hemolysis was measured by spectrophotometry. RESULTS: The expression levels of miR-16 and the degree of hemolysis were significantly higher in plasma than in serum (P<0.0001). Measured miR-21, miR-29a, miR-125b and miR-16 expression increased with hemoglobin levels in hemolyzed controls. The degree of hemolysis in serum samples correlated significantly with the levels of miR-21 (P<0.0001), miR-29a (P = 0.0002), miR-125b (P<0.0001) and miR-16 (P<0.0001). All four miRNAs showed significantly lower levels in sera that had been stored at 4°C for seven days (P<0.0001). Levels of miR-21 (P<0.0001), miR-29a (P<0.0001) and miR-16 (P = 0.0003), and the degree of hemolysis (P = 0.0002) were significantly higher in sera drawn after vs. before bowel preparation. CONCLUSIONS: The measured levels of miRNAs in serum and plasma from same patients varied in the presence of hemolysis, and since hemolysis and other factors affected miRNA expression, it is important to consider these confounders while developing miRNA-based diagnostic assays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MicroRNAs are transported in plasma and delivered to recipient cells by high-density lipoproteins
Vickers, K. C., Palmisano, B. T., Shoucri, B. M., Shamburek, R. D., & Remaley, A. T. (2011) · Nature Cell Biology · doi:10.1038/ncb2210 · Cited by 2,741 · cited 2×
“The stability of circulating miRNAs is attributed to their association with the Ago2 protein [7,8], high-density lipoprotein (HDL) [9] or their presence within microparticles such as exosomes [10,11,12]; which collectively underscores their possible usefulness as blood-based biomarkers for human diseases.”
BackgroundCharacterization of extracellular circulating microRNA
Turchinovich, A., Weiz, L., Langheinz, A., & Burwinkel, B. (2011) · Nucleic Acids Research · doi:10.1093/nar/gkr254 · Cited by 1,941
Blood Cell Origin of Circulating MicroRNAs: A Cautionary Note for Cancer Biomarker Studies
Pritchard, C. C., Kroh, E., Wood, B., Arroyo, J. D., Dougherty, K. J., Miyaji, M. M., Tait, J. F., & Tewari, M. (2012) · Cancer Prevention Research · doi:10.1158/1940-6207.capr-11-0370 · Cited by 879 · cited 3×
“This is consistent with previous reports [6,16,17,18,19,20,21], and suggests that circulating miRNA biomarker results might be erroneously interpreted in hemolyzed serum or plasma samples.”
BackgroundResultHaemolysis during sample preparation alters microRNA content of plasma
Kirschner, M. B., Kao, S. C., Edelman, J. J., Armstrong, N. J., Vallely, M. P., van Zandwijk, N., & Reid, G. (2011) · PLoS ONE · doi:10.1371/journal.pone.0024145 · Cited by 569
Methodological challenges in utilizing mi RNA s as circulating biomarkers
Moldovan, L., Batte, K. E., Trgovcich, J., Wisler, J., Marsh, C. B., & Piper, M. (2014) · Journal of Cellular and Molecular Medicine · doi:10.1111/jcmm.12236 · Cited by 436 · cited 4×
“[15] As a result, there is no consensus regarding the superiority of using serum or plasma for investigating circulating miRNAs [13].”
BackgroundInfluentialBaggish, A. L., Hale, A., Weiner, R. B., Lewis, G. D., Systrom, D., Wang, F., Wang, T. J., & Chan, S. Y. (2011) · The Journal of Physiology · doi:10.1113/jphysiol.2011.213363 · Cited by 431 · cited 1×
“reported that plasma levels of multiple miRNAs, including the biomarker miR-21, increased immediately after exhaustive exercise [22].”
Background
Cited by
Epilepsy biomarkers – Toward etiology and pathology specificity
Pitkänen, A., Ekolle Ndode-Ekane, X., Lapinlampi, N., & Puhakka, N. (2019) · Neurobiology of Disease · doi:10.1016/j.nbd.2018.05.007 · Cited by 172
Stability of circulating microRNAs in serum
Kupec, T., Bleilevens, A., Iborra, S., Najjari, L., Wittenborn, J., Maurer, J., & Stickeler, E. (2022) · PLOS ONE · doi:10.1371/journal.pone.0268958 · Cited by 60
miRNAs as therapeutic tools and biomarkers for prostate cancer
Arrighetti, N., & Beretta, G. L. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13030380 · Cited by 43
Blocking of targeted microRNAs from next-generation sequencing libraries
Roberts, B. S., Hardigan, A. A., Kirby, M. K., Fitz-Gerald, M. B., Wilcox, C. M., Kimberly, R. P., & Myers, R. M. (2015) · Nucleic Acids Research · doi:10.1093/nar/gkv724 · Cited by 8
Metadata
- Authors
- Yamada, A., Cox, M. A., Gaffney, K. A., Moreland, A., Boland, C. R., & Goel, A.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2014-11-18
- Volume
- 9
- Issue
- 11
- Pages
- e112481
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W1989944001
- Cited by
- 51
- References
- 6
- FWCI
- 2.24
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.