Thermal Transport Characteristics of Human Skin Measured In Vivo Using Ultrathin Conformal Arrays of Thermal Sensors and Actuators
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Measurements of the thermal transport properties of the skin can reveal changes in physical and chemical states of relevance to dermatological health, skin structure and activity, thermoregulation and other aspects of human physiology. Existing methods for in vivo evaluations demand complex systems for laser heating and infrared thermography, or they require rigid, invasive probes; neither can apply to arbitrary regions of the body, offers modes for rapid spatial mapping, or enables continuous monitoring outside of laboratory settings. Here we describe human clinical studies using mechanically soft arrays of thermal actuators and sensors that laminate onto the skin to provide rapid, quantitative in vivo determination of both the thermal conductivity and thermal diffusivity, in a completely non-invasive manner. Comprehensive analysis of measurements on six different body locations of each of twenty-five human subjects reveal systematic variations and directional anisotropies in the characteristics, with correlations to the thicknesses of the epidermis (EP) and stratum corneum (SC) determined by optical coherence tomography, and to the water content assessed by electrical impedance based measurements. Multivariate statistical analysis establishes four distinct locations across the body that exhibit different physical properties: heel, cheek, palm, and wrist/volar forearm/dorsal forearm. The data also demonstrate that thermal transport correlates negatively with SC and EP thickness and positively with water content, with a strength of correlation that varies from region to region, e.g., stronger in the palmar than in the follicular regions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures









Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Specifically, these skin-like thermal actuators can be used for prosthetic applications,[106,502] AR/VR feedback thermal stimulators,[191,503,504] and thermal therapy in rehabilitation.[505–507]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [502]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Endowing e-skins with”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [502]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carslaw, H. S., & Jaeger, J. C. (1947) · International Linear Collider · Cited by 21,232
Tranter, C. J. (1959) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(59)90029-8 · Cited by 18,388
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationHighly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291 · cited 1×
“Here, we introduce strategies that exploit ultrathin, soft systems [9–18] of thermal actuators and sensors for robust, precise transport measurements, in a non-invasive manner that can rapidly capture both orientation and position dependent characteristics.”
MethodAn ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485
Gustafsson, S. E. (1991) · Review of Scientific Instruments · doi:10.1063/1.1142087 · Cited by 1,480 · cited 1×
“The effective depth associated with the measurement can be approximated as [20] Dp 1⁄4 ffiffiffiffiffiffiffiffiffi atmax p ð2Þ”
Someya, T., Kato, Y., Sekitani, T., Iba, S., Noguchi, Y., Murase, Y., Kawaguchi, H., & Sakurai, T. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0502392102 · Cited by 1,389 · cited 1×
“Here, we introduce strategies that exploit ultrathin, soft systems [9–18] of thermal actuators and sensors for robust, precise transport measurements, in a non-invasive manner that can rapidly capture both orientation and position dependent characteristics.”
MethodUltrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229 · cited 1×
“Our recent report [10] introduced a type of thermal sensor with thickness, modulus and thermal mass matched to the epidermis, for spatiotemporal mapping of temperature on the surface of the skin with precision equal to or better than that of state-of-the-art infrared thermography systems.”
BackgroundSelf-citationEgawa, M., Hirao, T., & Takahashi, M. (2007) · Acta Dermato-Venereologica · doi:10.2340/00015555-0183 · Cited by 336 · cited 1×
“OCT yielded accurate values of SC thickness for the palm and heel pad but not for the follicular regions, where previous studies indicate a typical value of ~15 μm [21–23].”
ResultStretchability of thin metal films on elastomer substrates
Li, T., Huang, Z., Suo, Z., Lacour, S. P., & Wagner, S. (2004) · Applied Physics Letters · doi:10.1063/1.1806275 · Cited by 315 · cited 1×
“Here, we introduce strategies that exploit ultrathin, soft systems [9–18] of thermal actuators and sensors for robust, precise transport measurements, in a non-invasive manner that can rapidly capture both orientation and position dependent characteristics.”
Method
Research works printed but not linked: 1
- Graffe KVD (2001) Human Anatomy: McGraw Hill.
Cited by
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
“stratum corneum thickness, and skin hydration level.(44) A modified version of this device has”
BackgroundMethodFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Liu, Y., Norton, J. J. S., Qazi, R., Zou, Z., Ammann, K. R., Liu, H., Yan, L., Tran, P. L., Jang, K.-I., Lee, J. W., et al. (2016) · Science Advances · doi:10.1126/sciadv.1601185 · Cited by 397
“Examples include precision measurement of temperature and thermal transport characteristics ( 14 , 15 ), recording of electrophysiological processes and variations in electrical impedance ( 16 – 18 ), characterization of skin stiffness ( 5 , 19 ), and monitoring of quasi-static or dynamic…”
Self-citationInkjet-Printed Graphene/PEDOT:PSS Temperature Sensors on a Skin-Conformable Polyurethane Substrate
Vuorinen, T., Niittynen, J., Kankkunen, T., Kraft, T. M., & Mäntysalo, M. (2016) · Scientific Reports · doi:10.1038/srep35289 · Cited by 335
Self-citationAdvanced Materials for Health Monitoring with Skin‐Based Wearable Devices
Jin, H., Abu‐Raya, Y. S., & Haick, H. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700024 · Cited by 317
Papanastasiou, D. T., Schultheiss, A., Muñoz‐Rojas, D., Celle, C., Carella, A., Simonato, J., & Bellet, D. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201910225 · Cited by 276
Webb, R. C., Ma, Y., Krishnan, S., Li, Y., Yoon, S., Guo, X., Feng, X., Shi, Y., Seidel, M., Cho, N. H., et al. (2015) · Science Advances · doi:10.1126/sciadv.1500701 · Cited by 244
Self-citationIntrinsically Stretchable Biphasic (Solid–Liquid) Thin Metal Films
Hirsch, A., Michaud, H. O., Gerratt, A. P., de Mulatier, S., & Lacour, S. P. (2016) · Advanced Materials · doi:10.1002/adma.201506234 · Cited by 234
Microclimate: A critical review in the context of pressure ulcer prevention
Kottner, J., Black, J., Call, E., Gefen, A., & Santamaria, N. (2018) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2018.09.010 · Cited by 187
“However, besides hydration the thermal transport properties differ between skin areas (Webb et al., 2015).”
Biomarkers and Detection Platforms for Human Health and Performance Monitoring: A Review
Sim, D., Brothers, M. C., Slocik, J. M., Islam, A. E., Maruyama, B., Grigsby, C. C., Naik, R. R., & Kim, S. S. (2022) · Advanced Science · doi:10.1002/advs.202104426 · Cited by 186
Yang, T., Kim, J. R., Jin, H., Gil, H., Koo, J., & Kim, H. J. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008831 · Cited by 178
Soft Electronics for the Skin: From Health Monitors to Human–Machine Interfaces
Rao, Z., Ershad, F., Almasri, A., Gonzalez, L., Wu, X., & Yu, C. (2020) · Advanced Materials Technologies · doi:10.1002/admt.202000233 · Cited by 159
Recent advances in multi-mode haptic feedback technologies towards wearable interfaces
Huang, Y., Yao, K., Li, J., Li, D., Jia, H., Liu, Y., Yiu, C. K., Park, W., & Yu, X. (2021) · Materials Today Physics · doi:10.1016/j.mtphys.2021.100602 · Cited by 157
Material and structural considerations for high-performance electrodes for wearable skin devices
Lim, K., Seo, H., Chung, W. G., Song, H., Oh, M., Ryu, S. Y., Kim, Y., & Park, J. (2024) · Communications Materials · doi:10.1038/s43246-024-00490-8 · Cited by 148
Wang, H., Pastorin, G., & Lee, C. (2016) · Advanced Science · doi:10.1002/advs.201500441 · Cited by 121
Flexible and Stretchable 3ω Sensors for Thermal Characterization of Human Skin
Tian, L., Li, Y., Webb, R. C., Krishnan, S., Bian, Z., Song, J., Ning, X., Crawford, K., Kurniawan, J., Bonifas, A., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201701282 · Cited by 117
Self-citationUllah, H., Wahab, M. A., Will, G. D., Karim, M. R., Pan, T., Gao, M., Lai, D., Lin, Y., & Miraz, M. H. (2022) · Biosensors · doi:10.3390/bios12080630 · Cited by 122
Krishnan, S. R., Su, C., Xie, Z., Patel, M., Madhvapathy, S. R., Xu, Y., Freudman, J., Ng, B., Heo, S. Y., Wang, H., et al. (2018) · Small · doi:10.1002/smll.201803192 · Cited by 102
Self-citationKrishnan, S. R., Ray, T. R., Ayer, A. B., Ma, Y., Gutruf, P., Lee, K., Lee, J. Y., Wei, C., Feng, X., Ng, B., et al. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aat8437 · Cited by 89
Self-citationRecent Developments of Flexible and Stretchable Electrochemical Biosensors
Yang, X., & Cheng, H. (2020) · Micromachines · doi:10.3390/mi11030243 · Cited by 90
“, temperature [5,6], motion [7,8], respiration rate [9,10], and gas exposure [11,12] among others) and electrophysiological signals (e.”
BackgroundA Review of Skin-Wearable Sensors for Non-Invasive Health Monitoring Applications
Mao, P., Li, H., & Yu, Z. (2023) · Sensors · doi:10.3390/s23073673 · Cited by 95
“Cr/Au FS Voltage Cheek Vascularization, blood flow, stratum corneum thickness, hydration Ecoflex 00–30 [57]”
BackgroundInfluentialMadhvapathy, S. R., Wang, H., Kong, J., Zhang, M. Z., Lee, J. Y., Park, J. B., Jang, H., Xie, Z., Cao, J., Avila, R. O., et al. (2020) · Science Advances · doi:10.1126/sciadv.abd7146 · Cited by 81
Self-citationMadhvapathy, S. R., Ma, Y., Patel, M., Krishnan, S., Wei, C., Li, Y., Xu, S., Feng, X., Huang, Y., & Rogers, J. A. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201802083 · Cited by 73
Self-citationMultimodal epidermal devices for hydration monitoring
Krishnan, S., Shi, Y., Webb, R. C., Ma, Y., Bastien, P., Crawford, K. E., Wang, A., Feng, X., Manco, M., Kurniawan, J., et al. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2017.14 · Cited by 65
Self-citationLee, Y.-K., Xi, Z., Lee, Y. J., Kim, Y.-H., Hao, Y., Choi, H., Lee, M., Joo, Y., Kim, C., Lien, J., et al. (2020) · Science Advances · doi:10.1126/sciadv.aax6212 · Cited by 72
Koh, A., Gutbrod, S. R., Meyers, J. D., Lu, C., Webb, R. C., Shin, G., Li, Y., Kang, S., Huang, Y., Efimov, I. R., et al. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201500451 · Cited by 61
Self-citationOkabe, T., Fujimura, T., Okajima, J., Aiba, S., & Maruyama, S. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.06.039 · Cited by 60
Patchable micro/nanodevices interacting with skin
Bai, W., Kuang, T., Chitrakar, C., Yang, R., Li, S., Zhu, D., & Chang, L. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.09.035 · Cited by 57
Krishnan, S. R., Arafa, H., Kwon, K., Deng, Y., Su, C.-J., Reeder, J. T., Freudman, J., Stankiewicz, I., Chen, H.-M., Loza, R., et al. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0239-1 · Cited by 51
Self-citationHighly Stable Battery Pack via Insulated, Reinforced, Buckling‐Enabled Interconnect Array
Yin, L., Seo, J. K., Kurniawan, J. F., Kumar, R., Lv, J., Xie, L., Liu, X., Xu, S. H., Meng, Y. S., & Wang, J. (2018) · Small · doi:10.1002/smll.201800938 · Cited by 52
Self-citationRecent Trends of Functional Composites and Structures for Electromechanical Sensors: A Review
Vo, T. S., & Kim, K. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202300730 · Cited by 53
Advanced thermal sensing techniques for characterizing the physical properties of skin
Madhvapathy, S. R., Arafa, H., Patel, M. J., Winograd, J., Kong, J., Zhu, J., Xu, S., & Rogers, J. A. (2022) · Applied Physics Reviews · doi:10.1063/5.0095157 · Cited by 48
Self-citationGrigatti, A., & Gefen, A. (2021) · International Wound Journal · doi:10.1111/iwj.13650 · Cited by 37
“43 W/ mK.(63,64) The recent work of Crawford and colleagues, which reported anatomical-site-specific skin thermal conductivity data, revealed that the thermal conductivity of skin at the nose (the skin at the bridge of the nose commonly breaks down under prolonged pressure by CPAP masks(19,53);) is 0.”
BackgroundIntegration of biological systems with electronic-mechanical assemblies
Yi, N., Cui, H., Zhang, L. G., & Cheng, H. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.04.032 · Cited by 33
“, temperature and thermal transport [103, 104]), mechanical (e.”
BackgroundCrawford, K. E., Ma, Y., Krishnan, S. R., Wei, C., Capua, D. D., Xue, Y., Xu, S., Xie, Z., Won, S. M., Tian, L., et al. (2018) · Extreme Mechanics Letters · doi:10.1016/j.eml.2018.04.002 · Cited by 29
Self-citationDu, Y., Zhou, C., Feng, Y., & Qiu, L. (2024) · npj Flexible Electronics · doi:10.1038/s41528-024-00373-5 · Cited by 33
Thermodiffusion‐Assisted Pyroelectrics—Enabling Rapid and Stable Heat and Radiation Sensing
Chaharsoughi, M. S., Zhao, D., Xavier Crispin, A., Fabiano, S., & Jonsson, M. P. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201900572 · Cited by 27
Thin, Millimeter Scale Fingernail Sensors for Thermal Characterization of Nail Bed Tissue
Li, Y., Ma, Y., Wei, C., Luan, H., Xu, S., Han, M., Zhao, H., Liang, C., Yang, Q., Yang, Y., et al. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201801380 · Cited by 22
Self-citationAn overview of healthcare monitoring by flexible electronics
Hu, J., Li, R., Liu, Y., & Su, Y. (2018) · Science China Physics Mechanics and Astronomy · doi:10.1007/s11433-018-9239-9 · Cited by 18
Current and Potential Applications of Wearables in Sports Cardiology
Rao, P., Seshadri, D. R., & Hsu, J. J. (2021) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-021-00942-1 · Cited by 21
Advantages of in vivo measurement of human skin thermal conductance using a calorimetric sensor
de Rivera, P. J. R., de Rivera, M. R., Socorro, F., Calbet, J. A. L., & de Rivera, M. R. (2022) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-022-11275-x · Cited by 19
“Some authors employ similar procedures, using instruments that emit controlled dissipations and measure the temperature; being the dissipations stationary [16, 17], sinusoidal (3ω method) [18], or pulsed [10, 11].”
BackgroundMethodHow birds dissipate heat before, during and after flight
Lewden, A., Bishop, C. M., & Askew, G. N. (2023) · Journal of The Royal Society Interface · doi:10.1098/rsif.2023.0442 · Cited by 15
“…for heel assumed; [26]), T p is the temperature of the perch, K s is the thermal diffusivity of skin (1.41 × 10 − 7 m 2 s − 1 , value for heel assumed; [26]), A f is the area of the feet in contact with the perch and t is the time duration spent on the perch before the thermal image was recorded.”
BackgroundInfluentialTian, Y., Yang, K., Wang, Y., Wang, J., Carlini, A. S., Zhang, Z., Deng, Y., Tan, J., Peng, L., Yu, B., et al. (2024) · npj Flexible Electronics · doi:10.1038/s41528-024-00342-y · Cited by 17
“28).”
Biaxial mechanics of thermally denaturing skin - Part 1: Experiments
Meador, W. D., Sugerman, G. P., Tepole, A. B., & Rausch, M. K. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.09.033 · Cited by 14
de Rivera, P. J. R., de Rivera, M. R., Socorro, F., Callicó, G. M., Calbet, J. A. L., & de Rivera, M. R. (2021) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-021-11062-0 · Cited by 13
de Rivera, P. J. R., de Rivera, M. R., Socorro, F., & de Rivera, M. R. (2022) · Measurement · doi:10.1016/j.measurement.2022.111693 · Cited by 13
Siyoucef, S., Al-Aslani, R., Adnane, M., Rahman, M. M. U., Laleg‐Kirati, T., & Al-Naffouri, T. Y. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3558220 · Cited by 16
“While acquiring thermal data, it is important to consider factors such as local blood flow dynamics, skin structure, and ambient temperature, which may affect these measurements [28].”
Smart Materials for Wearable Healthcare Devices
Jin, H., Jin, Q., & Jian, J. (2018) · InTech eBooks · doi:10.5772/intechopen.76604 · Cited by 19
“With integrating 4 × 4 TCR (Cr/ Au) sensor array on a thin elastomeric substrate, this ultrathin conformal device gives reliable performance and minor deviations [45, 61].”
MethodDressings for preventing pressure ulcers: how do they work?
Avşar, P., Moore, Z. E. H., & Patton, D. (2021) · Journal of Wound Care · doi:10.12968/jowc.2021.30.1.33 · Cited by 11
In vivo measurement of skin heat capacity: advantages of the scanning calorimetric sensor
de Rivera, P. J. R., de Rivera, M. R., Socorro, F., & de Rivera, M. R. (2022) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-022-11416-2 · Cited by 10
“From thermal diffusivity, they determined the heat capacity in different areas of the human body [22], with a thermal penetration depth of approximately 0.”
BackgroundMethodInfluentialDominguez, S., Mackert, G. A., & Dobke, M. K. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-46143-6.00029-4 · Cited by 13
6.10 Electrically Conductive Nanocomposites
Feller, J. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.10006-2 · Cited by 9
Calibration and operation improvements of a calorimetric sensor for medical applications
de Rivera, P. J. R., de Rivera, M. R., Socorro, F., & de Rivera, M. R. (2021) · Measurement · doi:10.1016/j.measurement.2021.110134 · Cited by 9
A wireless optoelectronic skin patch for light delivery and thermal monitoring
Kim, H., Jin, Y., Achavananthadith, S., Lin, R., & Ho, J. S. (2021) · iScience · doi:10.1016/j.isci.2021.103284 · Cited by 9
“Infrared sensors, for example, are widely used in the clinic and are capable of non-contact thermal measurement, but require stable optical configurations that are difficult to achieve with a wearable device (Webb et al. 2015b; Beigzadeh et al., 2020; Wilson and Patterson 2008).”
BackgroundInfluentialMonitoring of some minor human skin lesions using a skin calorimeter
de Rivera, P. J. R., de Rivera, M. R., Socorro, F., & de Rivera, M. R. (2024) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-024-13204-6 · Cited by 7
Webb, R. C., Krishnan, S. R., & Rogers, J. A. (2016) · Microsystems and nanosystems · doi:10.1007/978-3-319-28694-5_6 · Cited by 11
Self-citationEffects of thermosensory aging well demonstrated by cold stimulations with high temporal resolution
Després, O., Lithfous, S., Pébayle, T., Casadio, C., & Dufour, A. (2019) · Muscle & Nerve · doi:10.1002/mus.26482 · Cited by 7
Garrido, I., Lagüela, S., Román, J. V., del Valle, E. M. M., & González‐Aguilera, D. (2020) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2020.119770 · Cited by 7
Trefilov, A. M. I., Oane, M., & Duta, L. (2025) · Materials · doi:10.3390/ma18153524 · Cited by 6
“At the macroscopic level, thermal conductivity in skin is generally treated as isotropic, with any anisotropy being relatively minor compared to mechanical anisotropy [35].”
de Rivera, M. R., & de Rivera, P. J. R. (2024) · Sensors · doi:10.3390/s24185927 · Cited by 6
“Since then, the most notable instrumentation in the field are Webb RC’s ultrathin conformal arrays of sensors and actuators [16,23], Li Gao’s epidermal photonic devices [24], and Limei Tian’s flexible and stretchable 3 ω sensors [17].”
BackgroundMethodA Method to Determine Human Skin Heat Capacity Using a Non-Invasive Calorimetric Sensor
de Rivera, P. J. R., de Rivera, M. R., Socorro, F., de Rivera, M. R., & Callicó, G. M. (2020) · Sensors · doi:10.3390/s20123431 · Cited by 6
“These indicators are similar to values obtained in other works [10,15,16].”
Resultde Rivera, P. J. R., de Rivera, M. R., Socorro, F., & de Rivera, M. R. (2023) · Sensors · doi:10.3390/s23094391 · Cited by 5
“In recent years, different sensors have been developed to characterize the thermal properties of the skin [3,4].”
BackgroundVariations of skin thermal diffusivity on different skin regions
Bajrami, D., Zubiaga, A., Renggli, T., Kirsch, C., Spano, F., Fehr, D., von Schulthess, P., Lindhorst‐Peters, A., Huber, S., Roider, E., et al. (2024) · Skin Research and Technology · doi:10.1111/srt.13622 · Cited by 5
Importance of 3D and Inkjet Printing For Tony Stark and the Iron Man Suit
Niittynen, J., & Pakkanen, J. (2018) · Superhero Science and Technology · doi:10.24413/sst.2018.1.2106 · Cited by 4
Self-citationChen, Y., Yuan, J., Zhang, Y., Huang, Y. Y., & Feng, X. (2017) · Journal of Applied Physics · doi:10.1063/1.4986882 · Cited by 3
Review of ultra-thin and skin-like solid electronics
Ying, C. H. E. N., Chen, Y., Li, H., Lu, B., & Feng, X. (2018) · Scientia Sinica Informationis · doi:10.1360/n112018-00106 · Cited by 3
Smart biomaterials for skin tissue engineering and health monitoring
Martín, C., Medina, D. M., Matesanz, A., de Velasco, D. A. O.-G., Acedo, P., & Jorcano, J. L. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-85671-3.00010-5 · Cited by 3
Data-Driven Contact-Based Thermosensation for Enhanced Tactile Recognition
Ma, T., & Zhang, M. (2024) · Sensors · doi:10.3390/s24020369 · Cited by 3
“PCA is a data analysis technique that can retain as much of the original features as possible while reducing data dimensions [33,34].”
MethodUtility of Thermographic Imaging for Callus Identification in Wound and Foot Care
Sadrzadeh-Afsharazar, F., Raizman, R., & Saiko, G. (2023) · Sensors · doi:10.3390/s23239376 · Cited by 3
“The thermal properties of the stratum corneum across several body locations were measured in [23].”
Murthy, P. N., Hossain, M. M., Kundu, S., Rangappa, S., & Shivakumar, H. N. (2025) · AAPS PharmSciTech · doi:10.1208/s12249-025-03091-x · Cited by 2
Temperature Response in Living Skin Tissue Subject to Convective Heat Flux
Das, S., Pal, T. K., Jana, R. N., & Makinde, O. D. (2018) · Defect and diffusion forum/Diffusion and defect data, solid state data. Part A, Defect and diffusion forum · doi:10.4028/www.scientific.net/ddf.387.1 · Cited by 2
A Learning Object Recommendation Model with User Mood Characteristics
Méndez, N. D. D., Zapata, Á. M. P., & Collazos, C. A. (2016) · Communications in computer and information science · doi:10.1007/978-3-319-39672-9_4 · Cited by 2
van der Tempel, L. (2018) · Measurement · doi:10.1016/j.measurement.2018.11.053 · Cited by 2
The development of equipment and testing procedure of mechanical tourniquets essential performance
Molodtsov, D., & Shevchenko, K. (2025) · Measurements infrastructure · doi:10.33955/v10(2025)-081 · Cited by 1
“The rubber container with liquid assures the flexibility and capability for Comparison of the 416-В [15-16] rubber and the human body in average characteristics [17-20] The following requirements for determination of MT essential performance according to [13] are stipulated and presented in Table 2.”
Case Study on Skin Calorimetry: Modeling Localized Muscle Heat Transfer During Exercise
de Rivera, P. J. R., de Rivera, M. R., Socorro, F., & de Rivera, M. R. (2025) · Biosensors · doi:10.3390/bios15090567 · Cited by 1
“Some methods have been developed to measure the skin thermal conductance [18–20], its heat capacity [21–23], and its thermal diffusivity [20,24].”
Development & application of a wearable non-differential calorimeter for skin heat transfer analysis
de Rivera, P. J. R., de Rivera, M. R., Socorro, F., & de Rivera, M. R. (2025) · PLoS ONE · doi:10.1371/journal.pone.0334062 · Cited by 1
“These parameters ( C skin and R skin ) appear to remain stable regardless of variations in thermostat, ambient, or core body temperatures under resting conditions, which agrees with previous studies in some cases [17,19,20,24].”
Application of a skin calorimeter to study local heat loss during exercise
de Rivera, P. J. R., de Rivera, M. R., Socorro, F., & de Rivera, M. R. (2025) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-025-14948-5 · Cited by 1
Moisture sensor based on heat transfer possessing insusceptibility to coating materials on skin
Hosono, M., Isozaki, A., Katoh, K., Ichikawa, Y., Iwase, E., Matsumoto, K., & Shimoyama, I. (2015) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2015.10.012 · Cited by 1
Modeling Skin Thermal Behavior with a Cutaneous Calorimeter: Local Parameters of Medical Interest
de Rivera, P. J. R., de Rivera, M. R., Socorro, F., & de Rivera, M. R. (2025) · Modelling—International Open Access Journal of Modelling in Engineering Science · doi:10.3390/modelling6020042 · Cited by 1
A Microthermal Sensor for Cryoablation Balloons
Natesan, H., Tian, L., Rogers, J. A., & Bischof, J. C. (2020) · Journal of Biomechanical Engineering · doi:10.1115/1.4047134 · Cited by 1
Self-citationПлаксин, С. А., & Фаршатова, Л. И. (2020) · Pirogov Russian Journal of Surgery · doi:10.17116/hirurgia202012159 · Cited by 1
The Biaxial Mechanics of Thermally Denaturing Skin - Part I: ExperimentsPreprint
Meador, W. D., Sugerman, G. P., Tepole, A. B., & Rausch, M. K. (2021) · SSRN Electronic Journal · doi:10.2139/ssrn.3869270 · Cited by 1
Papanastasiou, D. T. (2020) · theses.fr (ABES) · doi:10.70675/392da118zef59z454dzac54zd242a99e87cb · Cited by 2
Numerical Analysis and Validation of the Human Impact on the Conditions in Model Chamber
Radzikowska-Juś, W., Szudarek, M., Juś, A., & Owczarek, S. (2016) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-48923-0_19
Development of a Micro-thermal Sensor Based on 3-omega Technique for Dynamic Freezing Applications
Natesan, H. (2019) · University of Minnesota Digital Conservancy (University of Minnesota)
Shmendel, O. H., Tereshchenko, M. F., Tymchik, G. S., & Danyliuk, I. A. (2019) · KPI Science News · doi:10.20535/kpi-sn.2019.5-6.188316
Liquid Metal Toward Flexible Electronics
Fu, L., & Zeng, M. (2022) · Wiley eBooks · doi:10.1002/9783527828784.ch7
Nanobiosensors in Healthcare Diagnosis
Dhawan, R., Singh, J., & Avti, P. (2024) · Nanotechnology in the life sciences · doi:10.1007/978-3-031-72004-8_13
REMOVED: Wearable intelligent nanobiosystems
Dhawan, R., Singh, J., & Avti, P. (2025) · Elsevier eBooks · doi:10.1016/b978-0-323-90254-0.00017-9
Perspectives on Practical In Vitro Permeation Testing (IVPT) of Topical Products
Rangappa, S., & Murthy, S. N. (2025) · AAPS introductions in the pharmaceutical sciences · doi:10.1007/978-3-031-80525-7_6
Garg, S. P., Bajaj, A., Shah, K. V., Hanna, E., Putnam, G. L., Bai, I., Griffin, D. D., & Galiano, R. D. (2025) · Health Science Reports · doi:10.1002/hsr2.70846
Priego‐Quesada, J. I., Domingo-Clérigues, M., Cañada‐Soriano, M., de Anda, R. M. C. O., García‐Sanz, V., & Bellot‐Arcís, C. (2025) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-025-14577-y · Cited by 1
“Certain potentially relevant variables, such as epidermis thickness [30] or smoking status [31], were not included, which may have limited the explanatory power of the models.”
Simulating Infrared Facial Temperature for Recognition with a Heat Transfer-Inspired Model
Chen, C., Yang, J., Yu, J., Xu, H., & Xiao, X. (2025) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea65512.2025.11148736
“Under these extreme conditions, the influence of adaptive responses on thermal conductivity diminishes, and its variations stabilize [16].”
Tian, Y., Deng, Y., Tan, J., & Peng, L. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11254526
“However, due to the low thermal conductivity of biological tissue [15,16], it takes tens of seconds for the temperature field within the tissue to reach a steady state when the BFR changes.”
Simulation Study on Parameter Optimization of Laser Acupuncture Based on a Human Acupoint Skin Model
Zhao, Z., Han, S., Xie, S., Xue, W., Dong, H., Xue, R., & Li, P. (2026) · Photonics · doi:10.3390/photonics13010085
Witkoś, J., Bożek, M., Odrzywołek, W., Wilczyński, S., & Hartman‐Petrycka, M. (2026) · Scientific Reports · doi:10.1038/s41598-026-50459-5
Integrated thermal sensing of vascular morphology for haemodynamic monitoring
Tian, Y., Deng, Y., Tan, J., Peng, L., & Lin, Z.-Y. (2026) · Nature Sensors · doi:10.1038/s44460-026-00082-8
“Based on the corresponding relationship between real thermal diffusivity ( α ), equivalent thermal diffusivity ( α e ) and w , the influence of w on τ is summarized (see Supplementary Note 7 for detailed analysis) 54–56 .”
Qi, L., & Yang, T. (2026) · Micromachines · doi:10.3390/mi17091093
“Tissue thermophysical properties, including thermal conductivity and thermal diffusivity, are also important because they depend on tissue composition and water content and may change with skin dehydration, edema, inflammation, and other alterations in the local tissue environment [10–14].”
Metadata
- Authors
- Webb, R. C., Pielak, R. M., Bastien, P., Ayers, J., Niittynen, J., Kurniawan, J., Manco, M., Lin, A., Cho, N. H., Malyrchuk, V., Balooch, G., & Rogers, J. A.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- L'Oreal (United States) (US)
- L'Oréal (France) (FR)
- Tampere University of Technology (FI)
- Corresponding author
- Balooch, Guive
- Rogers, John A.
- ORCID
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-02-06
- Volume
- 10
- Issue
- 2
- Pages
- e0118131
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC4319855
- OpenAlex
- W2034602349
- Semantic Scholar
- f4d4409a4f6983736a7639803d8181edb397ae6a
- Cited by
- 98
- References
- 23
- Citations by year
- 2026: 4 · 2025: 14 · 2024: 8 · 2023: 6 · 2022: 7 · 2021: 11 · 2020: 11 · 2019: 5 · 2018: 15 · 2017: 7 · 2016: 7 · 2015: 3
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- National Science Foundation (1144245, DGE‐1 144 245)
- L'Oreal USA
- Tekes
- University of Illinois at Urbana-Champaign (DGE-1144245)
- Division of Materials Research
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Keywords
- thermal transport properties, in vivo skin measurement, thermal actuators, anisotropy, epidermal thickness, stratum corneum thickness, skin hydration, body region variation, thermoregulation
- MeSH terms
- Algorithms, Humans, Models, Theoretical, Regional Blood Flow, Skin Physiological Phenomena, Temperature, Thermosensing, Thermal Conductivity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.