Towards Personalized Cardiology: Multi-Scale Modeling of the Failing Heart
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Despite modern pharmacotherapy and advanced implantable cardiac devices, overall prognosis and quality of life of HF patients remain poor. This is in part due to insufficient patient stratification and lack of individualized therapy planning, resulting in less effective treatments and a significant number of non-responders. METHODS AND RESULTS: State-of-the-art clinical phenotyping was acquired, including magnetic resonance imaging (MRI) and biomarker assessment. An individualized, multi-scale model of heart function covering cardiac anatomy, electrophysiology, biomechanics and hemodynamics was estimated using a robust framework. The model was computed on n=46 HF patients, showing for the first time that advanced multi-scale models can be fitted consistently on large cohorts. Novel multi-scale parameters derived from the model of all cases were analyzed and compared against clinical parameters, cardiac imaging, lab tests and survival scores to evaluate the explicative power of the model and its potential for better patient stratification. Model validation was pursued by comparing clinical parameters that were not used in the fitting process against model parameters. CONCLUSION: This paper illustrates how advanced multi-scale models can complement cardiovascular imaging and how they could be applied in patient care. Based on obtained results, it becomes conceivable that, after thorough validation, such heart failure models could be applied for patient management and therapy planning in the future, as we illustrate in one patient of our cohort who received CRT-D implantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Active Shape Models-Their Training and Application
Cootes, T. F., Taylor, C. J., Cooper, D. H., & Graham, J. (1995) · Computer Vision and Image Understanding · doi:10.1006/cviu.1995.1004 · Cited by 7,190 · cited 1×
“A considerable variability of bi-ventricular shapes could be observed across the population, with an average variation of about 5mm around a mean atlas calculated from the population [47] (Fig 2B).”
BackgroundESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2012
Authors/Task Force Members, McMurray, J. J. V., Adamopoulos, S., Anker, S. D., Auricchio, A., Böhm, M., Dickstein, K., Falk, V., Filippatos, G., Fonseca, C., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs104 · Cited by 6,879
ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure 2012
Authors/Task Force Members, McMurray, J. J. V., Adamopoulos, S., Anker, S. D., Auricchio, A., Böhm, M., Dickstein, K., Falk, V., Filippatos, G., Fonseca, C., et al. (2012) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfs105 · Cited by 2,644
Moat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884 · cited 1×
“Its prevalence is estimated to increase by 25% till 2030 [1], with an associated health care expenditure increase of 120% in the same period.”
BackgroundThe Living Heart Project: A robust and integrative simulator for human heart function
Baillargeon, B., Rebelo, N., Fox, D. D., Taylor, R. L., & Kuhl, E. (2014) · European Journal of Mechanics - A/Solids · doi:10.1016/j.euromechsol.2014.04.001 · Cited by 370
Cited by
Artificial Intelligence in Cardiovascular Imaging
Dey, D., Slomka, P. J., Leeson, P., Comaniciu, D., Shrestha, S., Sengupta, P. P., & Marwick, T. H. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.12.054 · Cited by 680
Self-citationComputational models in cardiology
Niederer, S. A., Lumens, J., & Trayanova, N. A. (2019) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0104-y · Cited by 434
Strocchi, M., Augustin, C. M., Gsell, M. A. F., Karabelas, E., Neic, A., Gillette, K., Razeghi, O., Prassl, A. J., Vigmond, E. J., Behar, J. M., et al. (2020) · PLoS ONE · doi:10.1371/journal.pone.0235145 · Cited by 112
“One of the largest computational studies used forty-six biventricular meshes to simulate ventricular electrical activation and mechanical contraction [1].”
BackgroundArtificial Intelligence in Cardiovascular Medicine
Seetharam, K., Shrestha, S., & Sengupta, P. P. (2019) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-019-0728-1 · Cited by 76
Galappaththige, S., Gray, R. A., Costa, C. M., Niederer, S., & Pathmanathan, P. (2022) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1010541 · Cited by 45
“For example, [34] personalized a time constant in their cell model using the QT PLOS COMPUTATIONAL BIOLOGY Credibility assessment of patient-specific computational modeling”
Method
Metadata
- Authors
- Kayvanpour, E., Mansi, T., Sedaghat-Hamedani, F., Amr, A., Neumann, D., Georgescu, B., Seegerer, P., Kamen, A., Haas, J., Frese, K. S., Irawati, M., Wirsz, E., King, V., Buss, S., Mereles, D., Zitron, E., Keller, A., Katus, H. A., Comaniciu, D., & Meder, B.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-07-31
- Volume
- 10
- Issue
- 7
- Pages
- e0134869
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W1072488465
- Cited by
- 88
- References
- 5
- FWCI
- 6.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Towards Personalized Cardiology: Multi-Scale Modeling of the Failing Heart. https://app.cochat.ai/papers/10.1371/journal.pone.0134869
- The paper
- Kayvanpour, E., Mansi, T., Sedaghat-Hamedani, F., Amr, A., Neumann, D., Georgescu, B., Seegerer, P., Kamen, A., Haas, J., Frese, K. S., Irawati, M., Wirsz, E., King, V., Buss, S., Mereles, D., Zitron, E., Keller, A., Katus, H. A., Comaniciu, D., & Meder, B. (2015). Towards Personalized Cardiology: Multi-Scale Modeling of the Failing Heart. PLOS ONE. https://doi.org/10.1371/journal.pone.0134869
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.