CoChat

Credibility assessment of patient-specific computational modeling using patient-specific cardiac modeling as an exemplar

Open access
Galappaththige, Suran, Gray, Richard A., Costa, Caroline Mendonca, Niederer, Steven, Pathmanathan, Pras · 2022 · PLoS Computational Biology

The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.

Abstract

Reliable and robust simulation of individual patients using patient-specific models (PSMs) is one of the next frontiers for modeling and simulation (M&S) in healthcare. PSMs, which form the basis of digital twins, can be employed as clinical tools to, for example, assess disease state, predict response to therapy, or optimize therapy. They may also be used to construct virtual cohorts of patients, for in silico evaluation of medical product safety and/or performance. Methods and frameworks have recently been proposed for evaluating the credibility of M&S in healthcare applications. However, such efforts have generally been motivated by models of medical devices or generic patient models; how best to evaluate the credibility of PSMs has largely been unexplored. The aim of this paper is to understand and demonstrate the credibility assessment process for PSMs using patient-specific cardiac electrophysiological (EP) modeling as an exemplar. We first review approaches used to generate cardiac PSMs and consider how verification, validation, and uncertainty quantification (VVUQ) apply to cardiac PSMs. Next, we execute two simulation studies using a publicly available virtual cohort of 24 patient-specific ventricular models, the first a multi-patient verification study, the second investigating the impact of uncertainty in personalized and non-personalized inputs in a virtual cohort. We then use the findings from our analyses to identify how important characteristics of PSMs can be considered when assessing credibility with the approach of the ASME V&V40 Standard, accounting for PSM concepts such as inter- and intra-user variability, multi-patient and "every-patient" error estimation, uncertainty quantification in personalized vs non-personalized inputs, clinical validation, and others. The results of this paper will be useful to developers of cardiac and other medical image based PSMs, when assessing PSM credibility.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pcbi.1010541

Cites

54 of 54 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 Overview of cardiac electrophysiological models.
Fig 1 Overview of cardiac electrophysiological models.CC0 · PubMed Central
Fig 2 Five example UQ paradigms in patient-specific modeling. The N virtual patients could be N members of a virtual cohort in PSM-VC, or N new patients for a PSM-CT. In the first row, there is no UQ; the personalized parameter varies across the subjects, the non-personalized parameter is constant. In the second row, uncertainty in the personalized parameter (e.g., due to measurement error) is accounted for–represented here as a probability distribution, though other methods for accounting for uncertainty could be used. In the third row, uncertainty in the non-personalized parameter (e.g., due to population variability) is also accounted for. In the fourth row, some patient information is used to constrain the distributions for the ‘non-personalized’ parameters (e.g., if the parameter is known to differ between sexes). In the final row (PSM-VC only) the non-personalized parameter is randomly sampled in the cohort members, rather than taking the population average value for all patients. Other options are possible.
Fig 2 Five example UQ paradigms in patient-specific modeling. The N virtual patients could be N members of a virtual cohort in PSM-VC, or N new patients for a PSM-CT. In the first row, there is no UQ; the personalized parameter varies across the subjects, the non-personalized parameter is constant. In the second row, uncertainty in the personalized parameter (e.g., due to measurement error) is accounted for–represented here as a probability distribution, though other methods for accounting for uncertainty could be used. In the third row, uncertainty in the non-personalized parameter (e.g., due to population variability) is also accounted for. In the fourth row, some patient information is used to constrain the distributions for the ‘non-personalized’ parameters (e.g., if the parameter is known to differ between sexes). In the final row (PSM-VC only) the non-personalized parameter is randomly sampled in the cohort members, rather than taking the population average value for all patients. Other options are possible.CC0 · PubMed Central
Fig 3 A): left ventricular meshes for 24 patients (red–border zone; black–scar). B) base timing location for one patient. C) simulated V1 ECG for all patients (note: apical pacing not sinus rhythm).
Fig 3 A): left ventricular meshes for 24 patients (red–border zone; black–scar). B) base timing location for one patient. C) simulated V1 ECG for all patients (note: apical pacing not sinus rhythm).CC0 · PubMed Central
Fig 4 Discretization errors (defined as the difference between very low/low/medium results and the high-resolution results), for each patient, in normalized apex-to-base activation time (top row) and simulated ECG (middle and bottom rows). Note: Log scale used for top and middle rows. ECG lag errors (bottom row) take integer values, and since most results are exactly zero for the medium resolution meshes, a log scale is not used for ECG lag.
Fig 4 Discretization errors (defined as the difference between very low/low/medium results and the high-resolution results), for each patient, in normalized apex-to-base activation time (top row) and simulated ECG (middle and bottom rows). Note: Log scale used for top and middle rows. ECG lag errors (bottom row) take integer values, and since most results are exactly zero for the medium resolution meshes, a log scale is not used for ECG lag.CC0 · PubMed Central
Fig 5 A) repolarization gradient map for sample patient, pacing 0.2cm from scar. Colors represent repolarization gradient except scar is colored black. B) original mesh and meshes with expanded and contracted border zone for the same patient. Tissue is blue, BZ is red, scar is pink.
Fig 5 A) repolarization gradient map for sample patient, pacing 0.2cm from scar. Colors represent repolarization gradient except scar is colored black. B) original mesh and meshes with expanded and contracted border zone for the same patient. Tissue is blue, BZ is red, scar is pink.CC0 · PubMed Central
Fig 6 Impact of uncertainty in border zone extent on high repolarization gradient volumes (HRGV). A): boxplots comparing pacing at 0.2cm from scar with pacing 4.5cm from scar for each case. B): Range of HRGV values across each of the three cases (contracted BZ (stars), baseline (squares), expanded BZ (diamonds)) for each patient.
Fig 6 Impact of uncertainty in border zone extent on high repolarization gradient volumes (HRGV). A): boxplots comparing pacing at 0.2cm from scar with pacing 4.5cm from scar for each case. B): Range of HRGV values across each of the three cases (contracted BZ (stars), baseline (squares), expanded BZ (diamonds)) for each patient.CC0 · PubMed Central
Fig 7 Impact of uncertainty in tissue conductivity on high repolarization gradient volumes (HRGV). A): boxplots comparing pacing at 0.2cm from scar with pacing 4.5cm from scar for each case. B): Range of HRGV values across each of the three cases (low (diamonds), baseline (squares), high conductivity (stars)) for each patient.
Fig 7 Impact of uncertainty in tissue conductivity on high repolarization gradient volumes (HRGV). A): boxplots comparing pacing at 0.2cm from scar with pacing 4.5cm from scar for each case. B): Range of HRGV values across each of the three cases (low (diamonds), baseline (squares), high conductivity (stars)) for each patient.CC0 · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

1 more claim about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 54 references

Research works printed but not linked: 3

  1. ASME. V&V 40–2018 Assessing Credibility of Com putational Modeling through Verification and Validation: Application to Medical Devices. 2018.
  2. Costa CM. A Virtual Cohort of Twenty-four Left-ventricular Models of Ischemic Cardiomyopathy Patients. 2020.
  3. Kreinovich V, Nguyen HT, Niwitpong S-a. Statistical hypothesis testing under interval uncertainty: An overview. International Journal of Intelligent Technologies and Applied Statistics. 2008; 1(1): 1– 32.

Cited by

See all 45

Metadata

Authors
Galappaththige, S., Gray, R. A., Costa, C. M., Niederer, S., & Pathmanathan, P.
Affiliations
  • United States Food and Drug Administration (US)
  • King's College London (GB)
Corresponding author
Pathmanathan, Pras
Venue
PLoS Computational Biology
Published
2022-10-10
Volume
18
Issue
10
Pages
e1010541
ISSN
  • 1553-734X (ISSN-L)
  • 1553-7358
OpenAlex
W4304092601
Cited by
45
References
54
Citations by year
2026: 13 · 2025: 15 · 2024: 14 · 2023: 3
FWCI
5.61
Type
journal article
Language
en
Open access
Locations
  • PLoS Computational Biology (publishedVersion, public-domain)
  • PubMed Central (publishedVersion, public-domain)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
U.S. Food and Drug Administration
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Social Sciences › Education › Simulation-Based Education in Healthcare
  • Social Sciences › Decision Sciences › Management Science and Operations Research › Simulation Techniques and Applications
Keywords
patient-specific models, credibility assessment, digital twin, verification and validation, uncertainty quantification, virtual patient cohorts, ventricular model, clinical validation
MeSH terms
Computer Simulation, Heart, Humans, Cohort Studies, Uncertainty, Patient-Specific Modeling

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Credibility assessment of patient-specific computational modeling using patient-specific cardiac modeling as an exemplar. https://app.cochat.ai/papers/10.1371/journal.pcbi.1010541
The paper
Galappaththige, S., Gray, R. A., Costa, C. M., Niederer, S., & Pathmanathan, P. (2022). Credibility assessment of patient-specific computational modeling using patient-specific cardiac modeling as an exemplar. PLoS Computational Biology. https://doi.org/10.1371/journal.pcbi.1010541

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.