Estimation of Free-Living Energy Expenditure by Heart Rate and Movement Sensing: A Doubly-Labelled Water Study
Open accessThe DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Accurate assessment of energy expenditure (EE) is important for the study of energy balance and metabolic disorders. Combined heart rate (HR) and acceleration (ACC) sensing may increase precision of physical activity EE (PAEE) which is the most variable component of total EE (TEE). OBJECTIVE: To evaluate estimates of EE using ACC and HR data with or without individual calibration against doubly-labelled water (DLW) estimates of EE. DESIGN: 23 women and 23 men (22-55 yrs, 48-104 kg, 8-46%body fat) underwent 45-min resting EE (REE) measurement and completed a 20-min treadmill test, an 8-min step test, and a 3-min walk test for individual calibration. ACC and HR were monitored and TEE measured over 14 days using DLW. Diet-induced thermogenesis (DIT) was calculated from food-frequency questionnaire. PAEE (TEE ÷ REE ÷ DIT) and TEE were compared to estimates from ACC and HR using bias, root mean square error (RMSE), and correlation statistics. RESULTS: Mean(SD) measured PAEE and TEE were 66(25) kJ·day(-1)·kg(-1), and 12(2.6) MJ·day(-1), respectively. Estimated PAEE from ACC was 54(15) kJ·day(-1)·kg(-1) (p<0.001), with RMSE 24 kJ·day(-1)·kg(-1) and correlation r = 0.52. PAEE estimated from HR and ACC+HR with treadmill calibration were 67(42) and 69(25) kJ·day(-1)·kg(-1) (bias non-significant), with RMSE 34 and 20 kJ·day(-1)·kg(-1) and correlations r = 0.58 and r = 0.67, respectively. Similar results were obtained with step-calibrated and walk-calibrated models, whereas non-calibrated models were less precise (RMSE: 37 and 24 kJ·day(-1)·kg(-1), r = 0.40 and r = 0.55). TEE models also had high validity, with biases <5%, and correlations r = 0.71 (ACC), r = 0.66-0.76 (HR), and r = 0.76-0.83 (ACC+HR). CONCLUSIONS: Both accelerometry and heart rate may be used to estimate EE in adult European men and women, with improved precision if combined and if heart rate is individually calibrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These research devices (BodyMedia Core and Actiheart™) have been extensively validated and shown to accurately predict energy expenditure [11,20–28].”
From Assessment of laboratory and daily energy expenditure estimates from consumer multi-sensor physical activity monitors (2017) · cites this paper as [24]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“This method has been validated against gold-standard measures of energy expenditure in laboratory and free-living conditions [22–24].”
From Resting heart rate is a population-level biomarker of cardiorespiratory fitness: The Fenland Study (2023) · cites this paper as [24]
In the citing paper
“Individual calibration has been shown to improve energy expenditure prediction in free-living [24,26,27] and laboratory settings [23,25].”
From Assessment of laboratory and daily energy expenditure estimates from consumer multi-sensor physical activity monitors (2017) · cites this paper as [24]
In the citing paper
“The Actiheart™ has previously been validated against doubly labelled water [24,26,27] and has been used as a criterion measure of free-living energy expenditure in epidemiology studies [35].”
From Assessment of laboratory and daily energy expenditure estimates from consumer multi-sensor physical activity monitors (2017) · cites this paper as [24]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
New methods for calculating metabolic rate with special reference to protein metabolism
Weir, J. B. D. V. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004363 · Cited by 5,603
Age-predicted maximal heart rate revisited
Tanaka, H., Monahan, K. D., & Seals, D. R. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01054-8 · Cited by 3,775 · cited 1×
“5 minutes or less if 90% of age-predicted maximal HR [25] was reached.”
BackgroundPredicting basal metabolic rate, new standards and review of previous work.
Wn, S. (1985) · PubMed · Cited by 2,958
Basal metabolic rate studies in humans: measurement and development of new equations
Henry, C. (2005) · Public Health Nutrition · doi:10.1079/phn2005801 · Cited by 1,033 · cited 12×
“Sensitivity analyses were conducted disregarding measured RMR in all calculations (estimation and criterion), and instead using predicted RMR calculated with both the Oxford equations [46] and the Schofield equations [48].”
MethodInfluentialThe sources of external work in level walking and running.
Cavagna, G. A., Thys, H., & Zamboni, A. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011613 · Cited by 804 · cited 1×
“Although an 8 m s threshold would filter out some running activity [50], it may have been necessary for the specific accelerometer used by these investigators; a piezo-resistive accelerometer with a bandwidth filter of 0.”
MethodEnergy expenditure by doubly labeled water: validation in humans and proposed calculation
Schoeller, D. A., Ravussin, E., Schutz, Y., Acheson, K. J., Baertschi, P., & Jequier, E. (1986) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1986.250.5.r823 · Cited by 684 · cited 1×
“Moreover, the standardisation of isotopic dilution spaces reduces inflation of between-individual variance but ignores the biological variance that may exist which could impact on individual TEE and PAEE estimates [35,36,38,65], although measured dilution spaces in the current study were as expected.”
BackgroundReliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667 · cited 7×
“That said, the greater extent of missing data from free-living monitoring compared with laboratory conditions will inflate uncertainty and thus partly explains why PAEE assessed using the same method is often closer to the criterion value in laboratory evaluations [11,13,18].”
BackgroundMethodSelf-citationTate, D. F., Jackvony, E. H., & Wing, R. R. (2003) · JAMA · doi:10.1001/jama.289.14.1833 · Cited by 666 · cited 1×
“Most of these studies were conducted under controlled laboratory conditions and only four studies in adults have evaluated combined ACC+HR measures to predict EE during free-living assessed with the DLW technique [10,12,19,20], one only in men and two smaller studies using multiple sensors [10] which may increase the…”
MethodBingham, S. (1997) · International Journal of Epidemiology · doi:10.1093/ije/26.suppl_1.s137 · Cited by 634 · cited 1×
“At this time, the European Prospective Investigation into Cancer food frequency questionnaire (FFQ, containing 131 lines) was administered [33].”
MethodWesterterp, K. R. (2004) · Nutrition & Metabolism · doi:10.1186/1743-7075-1-5 · Cited by 570
Kumahara, H., Schutz, Y., Ayabe, M., Yoshioka, M., Yoshitake, Y., Shindo, M., Ishii, K., & Tanaka, H. (2004) · British Journal of Nutrition · doi:10.1079/bjn20031033 · Cited by 534 · cited 1×
“Only one group-calibrated ACC-PAEE equation was evaluated [13], as it has previously been shown that individual calibration of this relationship provides little or no improvement in estimation accuracy for daily living activities [18,30–32].”
MethodWickström (2000) · doi:10.5271/sjweh.555 · Cited by 526
Brage, S., Brage, N., Franks, P. W., Ekelund, U., Wong, M.-Y., Andersen, L. B., Froberg, K., & Wareham, N. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00703.2003 · Cited by 473 · cited 7×
“That said, the greater extent of missing data from free-living monitoring compared with laboratory conditions will inflate uncertainty and thus partly explains why PAEE assessed using the same method is often closer to the criterion value in laboratory evaluations [11,13,18].”
BackgroundMethodSelf-citationBlack, A. E., Prentice, A. M., Goldberg, G. R., Jebb, S. A., Bingham, S. A., Livingstone, M. B. E., & Coward, A. (1993) · Journal of the American Dietetic Association · doi:10.1016/0002-8223(93)91820-g · Cited by 414 · cited 1×
“Precise assessment of energy expenditure (EE) is essential for studies of energy balance and has been used to identify underreporting of food intake [1].”
MethodEnergy expenditure from minute-by-minute heart-rate recording: comparison with indirect calorimetry
Spurr, G., Prentice, A., Murgatroyd, P., Goldberg, G., Reina, J., & Christman, N. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/48.3.552 · Cited by 414
Ceesay, S. M., Prentice, A. M., Day, K. C., Murgatroyd, P. R., Goldberg, G. R., Scott, W., & Spurr, G. B. (1989) · British Journal of Nutrition · doi:10.1079/bjn19890107 · Cited by 318 · cited 3×
“For single-signal HR estimates, the flex-HRmethod as described elsewhere [27,28] was used.”
MethodBrage, S., Ekelund, U., Brage, N., Hennings, M. A., Froberg, K., Franks, P. W., & Wareham, N. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00092.2006 · Cited by 303
Self-citationHelmerhorst, H. J. F., Wijndaele, K., Brage, S., Wareham, N. J., & Ekelund, U. (2009) · Diabetes · doi:10.2337/db08-1773 · Cited by 258 · cited 1×
“In the original flex-HR studies using whole-body calorimetry as the criterion measure, flex-HR was defined as the average between highest HR during rest (lying awake, sitting, and standing) and lowest HR during activity [27,28], averaging around 81bpm but based on post hoc analysis another 10 bpm was added to correct…”
Self-citationWareham, N. J., & Rennie, K. L. (1998) · PubMed · Cited by 256
Self-citationEvaluation of methods to assess physical activity in free-living conditions
J. M. LEENDERS, N. Y., MICHAEL SHERMAN, W., NAGARAJA, H. N., & LAWRENCE KIEN, C. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200107000-00024 · Cited by 255 · cited 2×
“Finally, the precision of the DLWmethod used in the present study relies on the accuracy with which the participants report the collection time of urine samples and also on the assumptions on respiratory quotient and DIT which were calculated using data from a subjective food instrument as also done in other DLW studi…”
MethodResultJéquier, E. (2002) · International Journal of Obesity · doi:10.1038/sj.ijo.0802123 · Cited by 249 · cited 2×
“It is important to note, however, that DIT does vary depending on the individual’s diet, in particular protein intake [42].”
BackgroundMethodAccuracy of the Actiheart for the assessment of energy expenditure in adults
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2008) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602766 · Cited by 236 · cited 1×
“In particular, combining HR and ACC by branched equation modelling may be advantageous for estimating PAEE of structured common daily activities [13–15], unstructured activities [16,17], and a mixture of structured and unstructured activities performed in a whole-body calorimeter over a full day [18].”
MethodLivingstone, M., Prentice, A., Coward, W., Ceesay, S., Strain, J., McKenna, P., Nevin, G., Barker, M., & Hickey, R. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/52.1.59 · Cited by 231 · cited 2×
“Nonetheless, our results for daily EE estimation are in close agreement with those reported by Livingstone and colleagues using estimates of EE from 2–4 days HR-monitoring against DLW over 14 days [59], with RMSE = 34 kJ day kg and r = 0.”
MethodResultValidity of a short questionnaire to assess physical activity in 10 European countries
The InterAct Consortium (2012) · European Journal of Epidemiology · doi:10.1007/s10654-011-9625-y · Cited by 230 · cited 1×
“Group-calibrated HR estimates were derived using the average treadmill response from all individuals in the sample as previously described [13], and as a sensitivity analysis an out-of-sample group calibration was derived on the basis of 3865 step tests performed by 1941 adults from 10 European countries [29].”
MethodBouten, C. V., Verboeket-van de Venne, W. P., Westerterp, K. R., Verduin, M., & Janssen, J. D. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.2.1019 · Cited by 223 · cited 1×
“), and was cross-checked against individual activity logs [30].”
BackgroundGaussian process robust regression for noisy heart rate data
Stegle, O., Fallert, S. V., MacKay, D. J. C., & Brage, S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923118 · Cited by 213 · cited 2×
“HR data were pre-processed using a Bayesian approach as described elsewhere [43].”
MethodSelf-citationImproving energy expenditure estimation by using a triaxial accelerometer
Chen, K. Y., & Sun, M. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.6.2112 · Cited by 211 · cited 1×
“Only one group-calibrated ACC-PAEE equation was evaluated [13], as it has previously been shown that individual calibration of this relationship provides little or no improvement in estimation accuracy for daily living activities [18,30–32].”
MethodUrbanization, Physical Activity, and Metabolic Health in Sub-Saharan Africa
Assah, F. K., Ekelund, U., Brage, S., Mbanya, J. C., & Wareham, N. J. (2011) · Diabetes Care · doi:10.2337/dc10-0990 · Cited by 198 · cited 1×
“Monitor non-wear, however, is likely to also be a characteristic of studies in which the methods are applied but the summation method used in this and other studies [29,70–75] to integrate activity intensity time-series to one value per person minimises the impact of diurnal information bias [44].”
MethodSelf-citationMeasuring Free‐Living Energy Expenditure and Physical Activity with Triaxial Accelerometry
Plasqui, G., Joosen, A. M. C. P., Kester, A. D., Goris, A. H. C., & Westerterp, K. R. (2005) · Obesity Research · doi:10.1038/oby.2005.165 · Cited by 183 · cited 1×
“This is also similar to 29% and 34% added variance from uniaxial and triaxial acceleration in a sample of Dutch twins, although the latter was reported to be as high as 60%, depending on the statistical model chosen [52]; however these results have not yet been replicated in other populations.”
ResultWithers, R. T., LaForgia, J., Pillans, R. K., Shipp, N. J., Chatterton, B. E., Schultz, C. G., & Leaney, F. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.1.238 · Cited by 169 · cited 1×
“Body composition was assessed with the four-compartment model [23] using dual X-ray absorptiometry (Lunar Prodigy, GE Healthcare, USA), air-displacement plethysmography (BodPod, Life Measurement, Inc.”
MethodSimultaneous measurement of heart rate and body motion to quantitate physical activity
HASKELL, W. L., YEE, M. C., EVANS, A., & IRBY, P. J. (1993) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199301000-00015 · Cited by 155 · cited 1×
“For the assessment of PAEE, previous studies have demonstrated the advantage of integrating physiological measures, like heart rate (HR), with biomechanical measures such as acceleration (ACC) or other motion sensing [5–12].”
The doubly-labelled-water ( 2 H 2 18 O) method: principles and practice
Coward, W. A. (1988) · Proceedings of The Nutrition Society · doi:10.1079/pns19880037 · Cited by 150
Heritability of objectively assessed daily physical activity and sedentary behavior
Hoed, M. D., Brage, S., Zhao, J. H., Westgate, K., Nessa, A., Ekelund, U., Spector, T. D., Wareham, N. J., & Loos, R. J. (2013) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.113.069849 · Cited by 139
Self-citationAssah, F. K., Ekelund, U., Brage, S., Wright, A., Mbanya, J. C., & Wareham, N. J. (2011) · International Journal of Epidemiology · doi:10.1093/ije/dyq098 · Cited by 132
Self-citationThompson, D., Batterham, A. M., Bock, S., Robson, C., & Stokes, K. (2006) · The Journal of Nutrition · doi:10.1093/jn/136.4.1037 · Cited by 129 · cited 2×
“Weightings for the two most extreme branches vary slightly between previous evaluations [14,16,18,19]; as this matters most for the lower branch, we consolidated the two weightings, 0% and 10%, in the current study by applying the 0% weighting when average acceleration for the previous 2 min was lower than the movemen…”
MethodBrage, S., Brage, N., Ekelund, U., Luan, J., Franks, P. W., Froberg, K., & Wareham, N. J. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0112-6 · Cited by 127 · cited 1×
“Heart rate and acceleration were measured in all tests with a combined sensor (Actiheart, CamNtech Ltd, Papworth, UK), attached to standard ECG electrodes (Red Dot 2570, 3M) at the level just below the apex of the sternum as described elsewhere [11,26].”
MethodSelf-citationHoffman, D. J., Sawaya, A. L., Coward, W. A., Wright, A., Martins, P., de Nascimento, C., Tucker, K. L., & Roberts, S. B. (2000) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/72.4.1025 · Cited by 127 · cited 1×
“Isotopic enrichment of all samples was analysed in duplicate with minor modifications to procedures described in detail elsewhere [34].”
MethodSelf-citationRietjens, G. J., Kuipers, H., Kester, A. D., & Keizer, H. A. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-14342 · Cited by 126 · cited 1×
“This calorimetry system has been shown to provide valid measures of ventilation and gas fractions [24], which we confirmed for our specific piece of equipment using mechanical ventilation (iron lung) to dilute known concentrations of bottled oxygen, carbon dioxide, and nitrogen.”
MethodIntegration of physiological and accelerometer data to improve physical activity assessment
STRATH, S. J., BRAGE, S., & EKELUND, U. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185650.68232.3f · Cited by 126 · cited 4×
“in the form of a graded exercise test, with some evidence suggesting PAEE estimates from combined sensing may retain some accuracy even if dynamic individual calibration information was lacking [13,16,18,19].”
BackgroundMethodSelf-citationDoubly labeled water method: in vivo oxygen and hydrogen isotope fractionation
Schoeller, D. A., Leitch, C. A., & Brown, C. (1986) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1986.251.6.r1137 · Cited by 122 · cited 1×
“03 [38,39].”
Overnight and basal metabolic rates in men and women.
Goldberg, G. R., Prentice, A. M., Davies, H. L., & Murgatroyd, P. R. (1988) · PubMed · Cited by 119
Cooper, A. J. M., Brage, S., Ekelund, U., Wareham, N. J., Griffin, S. J., & Simmons, R. K. (2014) · Diabetologia · doi:10.1007/s00125-013-3069-8 · Cited by 114 · cited 1×
“Monitor non-wear, however, is likely to also be a characteristic of studies in which the methods are applied but the summation method used in this and other studies [29,70–75] to integrate activity intensity time-series to one value per person minimises the impact of diurnal information bias [44].”
MethodSelf-citationValidity of the simultaneous heart rate-motion sensor technique for measuring energy expenditure
STRATH, S. J., BASSETT, D. R., THOMPSON, D. L., & SWARTZ, A. M. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200205000-00025 · Cited by 112 · cited 1×
“For the assessment of PAEE, previous studies have demonstrated the advantage of integrating physiological measures, like heart rate (HR), with biomechanical measures such as acceleration (ACC) or other motion sensing [5–12].”
Villars, C., Bergouignan, A., Dugas, J., Antoun, E., Schoeller, D. A., Roth, H., Maingon, A. C., Lefai, E., Blanc, S., & Simon, C. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01413.2011 · Cited by 107 · cited 8×
“As for the latter, recent results by Villars et al in 35 French men, recruited by activity and obesity level [20], are likely closer to the implementation of the current study; these authors reported high precision of individually bike-test calibrated PAEE estimates (RMSE of 14 kJ day kg, r = 0.”
MethodResultInfluentialKlein, P., James, W. P. T., Wong, W. W., Irving, C. S., Murgatroyd, P. R., Cabrera, M. P., Dallosso, H. M., Klein, E. R., & Nichols, B. L. (1984) · PubMed · Cited by 103
Wareham, N. J., Wong, M.-Y., & Day, N. E. (2000) · American Journal of Epidemiology · doi:10.1093/aje/152.2.132 · Cited by 99 · cited 2×
“However, it should be noted that the flex HR point does not perfectly discriminate activity from rest, and typically fails to remove all influence of non-activity related elevations in HR and on other occasions filter out real low-intensity activity which may still be relevant for health [54,58].”
BackgroundMethodSelf-citationCole, T. J., & Coward, W. A. (1992) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1992.263.5.e965 · Cited by 98 · cited 2×
“Average internal error of uncorrected CO2 production measurements was 5%, as described in detail elsewhere [36,37].”
BackgroundMethodSimultaneous monitoring of heart rate and motion to assess energy expenditure
LUKE, A., MAKI, K. C., BARKEY, N., COOPER, R., & McGEE, D. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199701000-00021 · Cited by 97 · cited 1×
“For the assessment of PAEE, previous studies have demonstrated the advantage of integrating physiological measures, like heart rate (HR), with biomechanical measures such as acceleration (ACC) or other motion sensing [5–12].”
Correlated measurement error--implications for nutritional epidemiology
Day, N. (2004) · International Journal of Epidemiology · doi:10.1093/ije/dyh138 · Cited by 94 · cited 1×
“Given the inherent problems with subjective dietary assessment methods [66–69], an alternative approach would have been to ignore the biological variance in dietary composition and apply the same factors for everybody.”
BackgroundValidity of physical activity monitors for assessing lower intensity activity in adults
Calabr, M. A. S., Lee, J.-M., Saint-Maurice, P. F., Yoo, H., & Welk, G. J. (2014) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-014-0119-7 · Cited by 93 · cited 1×
“In particular, combining HR and ACC by branched equation modelling may be advantageous for estimating PAEE of structured common daily activities [13–15], unstructured activities [16,17], and a mixture of structured and unstructured activities performed in a whole-body calorimeter over a full day [18].”
MethodMeasurement error in epidemiology: the design of validation studies II: bivariate situation
Wong, M. Y., Day, N. E., & Wareham, N. J. (1999) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19991115)18:21<2831::aid-sim282>3.0.co;2-3 · Cited by 88 · cited 1×
“Thus, conclusions on dose-response relationships involving physical activity should be made with caution if PAEE is estimated from single-signal ACC or HR models, although other sources of error also come into play [55].”
BackgroundAdjusting for energy intake--what measure to use in nutritional epidemiological studies?
Jakes, R. W. (2004) · International Journal of Epidemiology · doi:10.1093/ije/dyh181 · Cited by 84 · cited 1×
“Given the inherent problems with subjective dietary assessment methods [66–69], an alternative approach would have been to ignore the biological variance in dietary composition and apply the same factors for everybody.”
BackgroundA combined heart rate and movement sensor: proof of concept and preliminary testing study
Rennie, K., Rowsell, T., Jebb, S., Holburn, D., & Wareham, N. (2000) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600973 · Cited by 83 · cited 1×
“For the assessment of PAEE, previous studies have demonstrated the advantage of integrating physiological measures, like heart rate (HR), with biomechanical measures such as acceleration (ACC) or other motion sensing [5–12].”
Self-citationEffect of Measurement Error on Energy-Adjustment Models in Nutritional Epidemiology
Kipnis, V., Freedman, L. S., Brown, C. C., Hartman, A. M., Schatzkin, A., & Wacholder, S. (1997) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a009202 · Cited by 78 · cited 1×
“Given the inherent problems with subjective dietary assessment methods [66–69], an alternative approach would have been to ignore the biological variance in dietary composition and apply the same factors for everybody.”
BackgroundRAFAMANTANANTSOA, H. H., EBINE, N., YOSHIOKA, M., HIGUCHI, H., YOSHITAKE, Y., TANAKA, H., SAITOH, S., & JONES, P. J. H. (2002) · Journal of Nutritional Science and Vitaminology · doi:10.3177/jnsv.48.517 · Cited by 77 · cited 1×
“An inflation of the between-individual variance of flex-HR estimates compared to DLW estimates was also observed, again similar to our results and those reported in Japanese [60,61] and French [20] but in contrast to the observations from Cameroon [19] and a small sample from Sweden [12].”
ResultDavidson, L., McNeill, G., Haggarty, P., Smith, J. S., & Franklin, M. F. (1997) · British Journal of Nutrition · doi:10.1079/bjn19970188 · Cited by 74 · cited 1×
“Some of this inflation may, however, be explained by discrepancies in length of HR and DLWmonitoring periods, as Davidson and colleagues observed only a small (12%) inflation of variance in nine adult men following a 9-day monitoring protocol for both HR and DLW after accounting for error in DLW estimates [62].”
BackgroundHustvedt, B.-E., Christophersen, A., Johnsen, L. R., Tomten, H., McNeill, G., Haggarty, P., & Løvø, A. (2004) · British Journal of Nutrition · doi:10.1079/bjn20041272 · Cited by 69 · cited 2×
“Most of these studies were conducted under controlled laboratory conditions and only four studies in adults have evaluated combined ACC+HR measures to predict EE during free-living assessed with the DLW technique [10,12,19,20], one only in men and two smaller studies using multiple sensors [10] which may increase the…”
MethodAssah, F. K., Brage, S., Ekelund, U., & Wareham, N. J. (2008) · Diabetologia · doi:10.1007/s00125-008-1033-9 · Cited by 68 · cited 1×
“In the original flex-HR studies using whole-body calorimetry as the criterion measure, flex-HR was defined as the average between highest HR during rest (lying awake, sitting, and standing) and lowest HR during activity [27,28], averaging around 81bpm but based on post hoc analysis another 10 bpm was added to correct…”
Self-citationGolubic, R., Martin, K. R., Ekelund, U., Hardy, R., Kuh, D., Wareham, N., Cooper, R., Brage, S., & teams, O. B. O. T. N. S. A. D. C. (2014) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-11-58 · Cited by 67 · cited 1×
“Monitor non-wear, however, is likely to also be a characteristic of studies in which the methods are applied but the summation method used in this and other studies [29,70–75] to integrate activity intensity time-series to one value per person minimises the impact of diurnal information bias [44].”
MethodSelf-citationSeven-day validation of doubly labeled water method using indirect room calorimetry
Seale, J. L., Conway, J. M., & Canary, J. J. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.1.402 · Cited by 64 · cited 2×
“Free-living energy expenditure was assessed with the doubly-labelled water (DLW) technique, which is the best standard for assessing TEE during free-living conditions and also compares favourably against whole-body calorimetry [2,3].”
MethodQuantifying the association between habitual energy expenditure and blood pressure
Wareham, N. J., Wong, M.-Y., Hennings, S., Mitchell, J., Rennie, K., Cruickshank, K., & Day, N. E. (2000) · International Journal of Epidemiology · doi:10.1093/ije/29.4.655 · Cited by 58 · cited 1×
“Such regression bias towards the mean in the exposure variable may lead to an overestimation of the dose-response relationship between predicted physical activity energy expenditure and health outcomes, which contrasts the effect of measurement error from HR models [53,54].”
MethodSelf-citationKASHIWAZAKI, H. (1999) · Journal of Nutritional Science and Vitaminology · doi:10.3177/jnsv.45.79 · Cited by 53 · cited 1×
“An inflation of the between-individual variance of flex-HR estimates compared to DLW estimates was also observed, again similar to our results and those reported in Japanese [60,61] and French [20] but in contrast to the observations from Cameroon [19] and a small sample from Sweden [12].”
ResultInfluence of body composition on physical activity validation studies using doubly labeled water
Mâsse, L. C., Fulton, J. E., Watson, K. L., Mahar, M. T., Meyers, M. C., & Wong, W. W. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00901.2003 · Cited by 50 · cited 1×
“This inter-relationship between accelerometry, body composition, and energy expenditure has also been observed by Masse et al [49], which warrants some caution when interpreting associations between the accelerometry estimate of PAEE and metabolic health outcomes.”
BackgroundCardiorespiratory fitness and physical activity in Luo, Kamba, and Maasai of rural Kenya
Christensen, D. L., Faurholt‐Jepsen, D., Boit, M. K., Mwaniki, D. L., Kilonzo, B., Tetens, I., Kiplamai, F. K., Cheruiyot, S. C., Friis, H., Borch‐Johnsen, K., et al. (2012) · American Journal of Human Biology · doi:10.1002/ajhb.22303 · Cited by 48 · cited 1×
“Monitor non-wear, however, is likely to also be a characteristic of studies in which the methods are applied but the summation method used in this and other studies [29,70–75] to integrate activity intensity time-series to one value per person minimises the impact of diurnal information bias [44].”
MethodSelf-citationCoward, W. A., Roberts, S. B., & Cole, T. J. (1988) · PubMed · Cited by 47
Avons, P., Garthwaite, P. H., Davies, H. L., Murgatroyd, P. R., & James, W. P. T. (1988) · PubMed · Cited by 42
Accelerometry combined with heart rate telemetry in the assessment of total energy expenditure
Johansson, H. P., Rossander-Hulthén, L., Slinde, F., & Ekblom, B. (2006) · British Journal of Nutrition · doi:10.1079/bjn20051527 · Cited by 35 · cited 4×
“One of these used a uniaxial accelerometer and a heart rate monitor, both calibrated to each of eight individuals’ energy expenditure during treadmill walking and running, and found best precision for combined ACC+HR model estimates, although not significantly different from either of the two single-signal models [12].”
MethodResultInfluentialPrecision of DLW energy expenditure measurements: contribution of natural abundance variations
Ritz, P., Cole, T. J., Couet, C., & Coward, W. A. (1996) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1996.270.1.e164 · Cited by 25 · cited 1×
“Average internal error of uncorrected CO2 production measurements was 5%, as described in detail elsewhere [36,37].”
MethodKlakeg, C. H., Pruitt, R. D., & Burchell, H. B. (1955) · American Heart Journal · doi:10.1016/0002-8703(55)90080-6 · Cited by 24 · cited 2×
“the postprandial phase following three meals per day and that meals would increase heart rate by an average of 10bpm [64] and stay elevated for two hours after each meal, the theoretical contribution to the PAEE estimates from this source would be in the order of 7 kJ day kg.”
BackgroundCorrelations between estimated and true dietary intakes
Fraser, G. E., & Shavlik, D. J. (2004) · Annals of Epidemiology · doi:10.1016/j.annepidem.2003.08.008 · Cited by 24 · cited 1×
“Given the inherent problems with subjective dietary assessment methods [66–69], an alternative approach would have been to ignore the biological variance in dietary composition and apply the same factors for everybody.”
BackgroundÜber das Verhalten des Kreislaufes bei Muskelarbeit nach dem Essen und bei Flüssigkeitszufuhr1
Jarisch, A., & Liljestrand, G. (1927) · Skandinavisches Archiv Für Physiologie · doi:10.1111/j.1748-1716.1927.tb00223.x · Cited by 22
Dahl‐Petersen, I. K., Bjerregaard, P., Brage, S., & Jørgensen, M. E. (2013) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2013.10.004 · Cited by 20 · cited 1×
“Monitor non-wear, however, is likely to also be a characteristic of studies in which the methods are applied but the summation method used in this and other studies [29,70–75] to integrate activity intensity time-series to one value per person minimises the impact of diurnal information bias [44].”
MethodSelf-citationFranks, P. W., Wong, M.-Y., Luan, J., Mitchell, J., Hennings, S., & Wareham, N. J. (2002) · British Journal of Nutrition · doi:10.1079/bjn2002663 · Cited by 20 · cited 1×
“However, it should be noted that the flex HR point does not perfectly discriminate activity from rest, and typically fails to remove all influence of non-activity related elevations in HR and on other occasions filter out real low-intensity activity which may still be relevant for health [54,58].”
BackgroundSelf-citation
Research works printed but not linked: 1
- Brage S, Westgate K, Wijndaele K, Godinho J, Griffin S, Wareham N. Evaluation of a method for minimising diurnal information bias in objective sensor data. ICAMPAM (Amherst) Conference Proceeding 2013.
Cited by
Shcherbina, A., Mattsson, C., Waggott, D., Salisbury, H., Christle, J., Hastie, T., Wheeler, M., & Ashley, E. (2017) · Journal of Personalized Medicine · doi:10.3390/jpm7020003 · Cited by 625
Wearable-device-measured physical activity and future health risk
Strain, T., Wijndaele, K., Dempsey, P. C., Sharp, S. J., Pearce, M., Jeon, J., Lindsay, T., Wareham, N., & Brage, S. (2020) · Nature Medicine · doi:10.1038/s41591-020-1012-3 · Cited by 355
Self-citationPhilip, A., & Kumar, A. R. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2022.214424 · Cited by 281
Chowdhury, E. A., Richardson, J. D., Holman, G. D., Tsintzas, K., Thompson, D., & Betts, J. A. (2016) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.115.122044 · Cited by 255
O’Driscoll, R., Turicchi, J., Beaulieu, K., Scott, S., Matu, J., Deighton, K., Finlayson, G., & Stubbs, J. (2020) · British Journal of Sports Medicine · doi:10.1136/bjsports-2018-099643 · Cited by 188
Metadata
- Authors
- Brage, S., Westgate, K., Franks, P. W., Stegle, O., Wright, A., Ekelund, U., & Wareham, N. J.
- Affiliations
- University of Cambridge (GB)
- Lund University (SE)
- European Bioinformatics Institute (GB)
- MRC Elsie Widdowson Laboratory (GB)
- Corresponding author
- Brage, Søren
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-09-08
- Volume
- 10
- Issue
- 9
- Pages
- e0137206
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC4562631
- OpenAlex
- W2171723694
- Semantic Scholar
- 9cfd7980e2973ab827b8941c570e13417e259926
- Cited by
- 151
- References
- 75
- Citations by year
- 2026: 10 · 2025: 7 · 2024: 9 · 2023: 7 · 2022: 12 · 2021: 18 · 2020: 13 · 2019: 26 · 2018: 21 · 2017: 18 · 2016: 10
- FWCI
- 12.04
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Apollo (University of Cambridge) (submittedVersion, cc-by)
- BIBSYS Brage (BIBSYS (Norway)) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Lund University Publications (Lund University) (submittedVersion)
- NORA - Norwegian Open Research Archives (submittedVersion, other-oa)
- Funders
- Wellcome Trust
- National Institute for Health and Care Research (NF-SI-0512-10135)
- Medical Research Council (MC_UU_12015, MC_UU_12015/3, MC_UU_12015/1)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Obesity, Physical Activity, Diet
- Keywords
- free-living energy expenditure, heart rate monitoring, accelerometry, doubly labeled water, physical activity energy expenditure, total energy expenditure, individual calibration, step test, walk test, diet-induced thermogenesis, energy balance, measurement validity, women and men comparison, body fat percentage
- MeSH terms
- Adult, Energy Metabolism, Fats, Female, Heart Rate, Humans, Male, Monitoring, Physiologic, Motor Activity, Rest, Urine, Water
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.