A Validated Smartphone-Based Assessment of Gait and Gait Variability in Parkinson’s Disease
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
BACKGROUND: A well-established connection exists between increased gait variability and greater fall likelihood in Parkinson's disease (PD); however, a portable, validated means of quantifying gait variability (and testing the efficacy of any intervention) remains lacking. Furthermore, although rhythmic auditory cueing continues to receive attention as a promising gait therapy for PD, its widespread delivery remains bottlenecked. The present paper describes a smartphone-based mobile application ("SmartMOVE") to address both needs. METHODS: The accuracy of smartphone-based gait analysis (utilizing the smartphone's built-in tri-axial accelerometer and gyroscope to calculate successive step times and step lengths) was validated against two heel contact-based measurement devices: heel-mounted footswitch sensors (to capture step times) and an instrumented pressure sensor mat (to capture step lengths). 12 PD patients and 12 age-matched healthy controls walked along a 26-m path during self-paced and metronome-cued conditions, with all three devices recording simultaneously. RESULTS: Four outcome measures of gait and gait variability were calculated. Mixed-factorial analysis of variance revealed several instances in which between-group differences (e.g., increased gait variability in PD patients relative to healthy controls) yielded medium-to-large effect sizes (eta-squared values), and cueing-mediated changes (e.g., decreased gait variability when PD patients walked with auditory cues) yielded small-to-medium effect sizes-while at the same time, device-related measurement error yielded small-to-negligible effect sizes. CONCLUSION: These findings highlight specific opportunities for smartphone-based gait analysis to serve as an alternative to conventional gait analysis methods (e.g., footswitch systems or sensor-embedded walkways), particularly when those methods are cost-prohibitive, cumbersome, or inconvenient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kok, J. S., Berg, I. J., & Scherder, E. J. A. (2013) · Dementia and Geriatric Cognitive Disorders Extra · doi:10.1159/000353441 · Cited by 20,589
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
Wearable Assistant for Parkinson’s Disease Patients With the Freezing of Gait Symptom
Bachlin, M., Plotnik, M., Roggen, D., Maidan, I., Hausdorff, J. M., Giladi, N., & Troster, G. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2036165 · Cited by 693 · cited 1×
“Several previous methods for portable RAC delivery combined with gait analysis have been proposed [50,56,102 – 104]; all, however, have been designed around the use of footswitches or shoe-mounted IMUs to collect the gait data itself.”
iTUG, a Sensitive and Reliable Measure of Mobility
Salarian, A., Horak, F. B., Zampieri, C., Carlson-Kuhta, P., Nutt, J. G., & Aminian, K. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047606 · Cited by 489
Rhythmic auditory stimulation modulates gait variability in Parkinson’s disease
Hausdorff, J. M., Lowenthal, J., Herman, T., Gruendlinger, L., Peretz, C., & Giladi, N. (2007) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2007.05810.x · Cited by 489 · cited 3×
“Importantly, individuals with higher-than-normal GV—both in PD and more broadly—are at increased risk of falling [6,16]; this association has been found using both retrospective [31] and prospective [12,32,33] designs.”
Quantitative wearable sensors for objective assessment of Parkinson's disease
Maetzler, W., Domingos, J., Srulijes, K., Ferreira, J. J., & Bloem, B. R. (2013) · Movement Disorders · doi:10.1002/mds.25628 · Cited by 374 · cited 1×
“Smartphone-based assessments in PD—including, but not limited to gait—offer numerous potential benefits: in terms of cost savings, portability, customizability, patient tolerance, and deployment scalability [2,69,70].”
Randomized controlled clinical trial of “virtual house calls” for Parkinson disease
Dorsey, E. R., Venkataraman, V., Grana, M. J., Bull, M. T., George, B. P., Boyd, C. M., Beck, C. A., Rajan, B., Seidmann, A., & Biglan, K. M. (2013) · JAMA Neurology · doi:10.1001/jamaneurol.2013.123 · Cited by 235
Weiss, A., Herman, T., Plotnik, M., Brozgol, M., Maidan, I., Giladi, N., Gurevich, T., & Hausdorff, J. M. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.10.015 · Cited by 207
A wearable system for gait training in subjects with Parkinson's disease
Casamassima, F., Ferrari, A., Milosevic, B., Ginis, P., Farella, E., & Rocchi, L. (2014) · Sensors · doi:10.3390/s140406229 · Cited by 131 · cited 1×
“Several previous methods for portable RAC delivery combined with gait analysis have been proposed [50,56,102 – 104]; all, however, have been designed around the use of footswitches or shoe-mounted IMUs to collect the gait data itself.”
Concurrent validity of accelerometry to measure gait in Parkinsons Disease
Lord, S., Rochester, L., Baker, K., & Nieuwboer, A. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.04.001 · Cited by 69 · cited 1×
“Other measurement approaches (reviewed in [43–45]) center around the use of an inertial measurement unit (comprising a tri-axial accelerometer and/or tri-axial gyroscope) affixed to the torso [46–49], feet [50–54], or multiple locations [55–57], and which compute outcome measures from a series of heel strike “analogue…”
Cited by
Digital biomarkers for Alzheimer’s disease: the mobile/wearable devices opportunity
Kourtis, L. C., Regele, O. B., Wright, J. M., & Jones, G. B. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0084-2 · Cited by 476
Zhan, A., Mohan, S., Tarolli, C., Schneider, R. B., Adams, J. L., Sharma, S., Elson, M. J., Spear, K. L., Glidden, A. M., Little, M. A., et al. (2018) · JAMA Neurology · doi:10.1001/jamaneurol.2018.0809 · Cited by 381
IoT Wearable Sensors and Devices in Elderly Care: A Literature Review
Stavropoulos, T. G., Papastergiou, A., Mpaltadoros, L., Nikolopoulos, S., & Kompatsiaris, I. (2020) · Sensors · doi:10.3390/s20102826 · Cited by 348
New methods for the assessment of Parkinson's disease (2005 to 2015): A systematic review
Sánchez‐Ferro, Á., Elshehabi, M., Godinho, C., Salkovic, D., Hobert, M. A., Domingos, J., van Uem, J. M., Ferreira, J. J., & Maetzler, W. (2016) · Movement Disorders · doi:10.1002/mds.26723 · Cited by 145
“At their current stage of development, IMUs are primarily used to assess bradykinesia,(25) tremors,(26) and axial features.(27) Virtually all cardinal motor features (perhaps with the exception of rigidity, for which only a small number of studies are currently available) can be quantified with these systems, at least…”
BackgroundReinertsen, E., & Clifford, G. D. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aabf64 · Cited by 136
Metadata
- Authors
- Ellis, R. J., Ng, Y. S., Zhu, S., Tan, D. M., Anderson, B., Schlaug, G., & Wang, Y.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-10-30
- Volume
- 10
- Issue
- 10
- Pages
- e0141694
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W1932263918
- Cited by
- 152
- References
- 10
- FWCI
- 40.54
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.