On the Potential of a New Generation of Magnetometers for MEG: A Beamformer Simulation Study
Open accessThe DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Abstract
Magnetoencephalography (MEG) is a sophisticated tool which yields rich information on the spatial, spectral and temporal signatures of human brain function. Despite unique potential, MEG is limited by a low signal-to-noise ratio (SNR) which is caused by both the inherently small magnetic fields generated by the brain, and the scalp-to-sensor distance. The latter is limited in current systems due to a requirement for pickup coils to be cryogenically cooled. Recent work suggests that optically-pumped magnetometers (OPMs) might be a viable alternative to superconducting detectors for MEG measurement. They have the advantage that sensors can be brought to within ~4 mm of the scalp, thus offering increased sensitivity. Here, using simulations, we quantify the advantages of hypothetical OPM systems in terms of sensitivity, reconstruction accuracy and spatial resolution. Our results show that a multi-channel whole-head OPM system offers (on average) a fivefold improvement in sensitivity for an adult brain, as well as clear improvements in reconstruction accuracy and spatial resolution. However, we also show that such improvements depend critically on accurate forward models; indeed, the reconstruction accuracy of our simulated OPM system only outperformed that of a simulated superconducting system in cases where forward field error was less than 5%. Overall, our results imply that the realisation of a viable whole-head multi-channel OPM system could generate a step change in the utility of MEG as a means to assess brain electrophysiological activity in health and disease. However in practice, this will require both improved hardware and modelling algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures








Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Increased proximity to the scalp can improve sensitivity and spatial resolution beyond that which is achieved using a cryogenic MEG [26,27].”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [26]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Dynamic predictions: Oscillations and synchrony in top–down processing
Engel, A. K., Fries, P., & Singer, W. (2001) · Nature Reviews Neuroscience · doi:10.1038/35094565 · Cited by 3,454 · cited 1×
“Invasive measures show clearly that such zero-phase lag effects exist in the brain [64, 65] and are currently missed by MEG.”
BackgroundNeuronal Synchrony: A Versatile Code for the Definition of Relations?
Singer, W. (1999) · Neuron · doi:10.1016/s0896-6273(00)80821-1 · Cited by 2,581
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561
Stam, C. J., Nolte, G., & Daffertshofer, A. (2007) · Human Brain Mapping · doi:10.1002/hbm.20346 · Cited by 2,018
Interpreting magnetic fields of the brain: minimum norm estimates
Hämäläinen, M. S., & Ilmoniemi, R. J. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02512476 · Cited by 1,995 · cited 1×
“However, many algorithms (for example minimum-norm [5, 6] and beamforming [7–11]) now exist to verifiably reconstruct the spatial, temporal and spectral signature of human brain activity with reasonable (~5–10 mm; [12, 13]) spatial resolution and excellent (<1 ms) temporal resolution.”
High-sensitivity diamond magnetometer with nanoscale resolution
Taylor, J. M., Cappellaro, P., Childress, L., Jiang, L., Budker, D., Hemmer, P. R., Yacoby, A., Walsworth, R., & Lukin, M. D. (2008) · Nature Physics · doi:10.1038/nphys1075 · Cited by 1,959 · cited 1×
“Note that in principle our theoretical systems could result from any technology in which the external surface of the magnetic field sensor is at room temperature, for example nitrogen-vacancy centres in diamond [48]; however we specifically use the term OPM throughout the paper due to the excellent potential of these…”
MethodThe five percent electrode system for high-resolution EEG and ERP measurements
Oostenveld, R., & Praamstra, P. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00527-7 · Cited by 1,909
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843 · cited 1×
“In order to simulate magnetic fields at the individual sensor locations, a multiple local sphere head model was used [52] in conjunction with the forward model derived by Sarvas [53].”
MethodDynamic imaging of coherent sources: studying neural interactions in the human brain
Gross, J., Kujala, J., Hämäläinen, M., Timmermann, L., Schnitzler, A., & Salmelin, R. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.2.694 · Cited by 1,810 · cited 1×
“Beamforming [7, 9, 11, 55, 56] is a popular solution to the MEG inverse problem that has been used extensively for MEG, particularly in the study of neural oscillations and functional connectivity.”
Method
Research works printed but not linked: 3
- Vrba J, Anderson G, Betts K, Burbank M, Cheung T, Cheyne D, et al 151-Channel whole-cortex MEG system for seated or supine positions In: Yoshimoto T, Kotani M, Kuriki S, Karibe H, Nakasato N, editors. Recent Advances in Biomagnetism. Sendai, Japan: Tohoku University Press; 1999 p. 93– 6.
- Johnson CN, Schwindt PDD, Weisend M. Multi-sensor magnetoencephalography with atomic magnetometers. Physics in Medicine and Biology. 2013; 58(17): 6065– 77.table 10.1088/0031-9155/58/17/6065 23939051 PMC4030549 · DOI · Paper page
- Sander T, Preusser J, Mhaskar R, Kitching J, Trahms L, Knappe S. Magnetoencephalography with a chip-scale atomic magnetometer. Biomedical Optics Express. 2012; 3(5): 981– 90. 10.1364/BOE.3.000981 22567591 PMC3342203 · DOI · Paper page
Cited by
Items 101–200 of 205
Sensor array design of optically pumped magnetometers for accurately estimating source currents
Takeda, Y., Gomi, T., Umebayashi, R., Tomita, S., Suzuki, K., Hiroe, N., Saikawa, J., Munaka, T., & Yamashita, O. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120257 · Cited by 13
“Recently, a new device was introduced ( Shah and Wakai, 2013 ), an optically pumped magnetometer (OPM), which has attracted great interest from the MEG community ( Boto et al., 2016; 2017; Brookes et al., 2022; Ilmoniemi and Sarvas, 2019; Tierney et al., 2019 ).”
Ingleby, S. J., Griffin, P. F., Arnold, A. S., Chouliara, M., & Riis, E. (2017) · Review of Scientific Instruments · doi:10.1063/1.4980159 · Cited by 13
Huang, B., Liu, Y., Li, R., Li, J., Tang, J., & Zhai, Y. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115523 · Cited by 12
Chai, C., Yang, X. M., Zheng, Y., Heyat, M. B. B., Li, Y., Yang, D.-B., Chen, Y.-H., & Sawan, M. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117321 · Cited by 15
Westin, K., Pfeiffer, C., Andersen, L. M., Ruffieux, S., Cooray, G., Kalaboukhov, A., Winkler, D., Ingvar, M., Schneiderman, J. F., & Lundqvist, D. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.03.041 · Cited by 12
Wireless optically pumped magnetometer MEG
Cheng, H., He, K., Li, C., Ma, X., Zheng, F., Xu, W., Liao, P., Yang, R., Li, D., Qin, L., et al. (2024) · NeuroImage · doi:10.1016/j.neuroimage.2024.120864 · Cited by 11
“Moreover, OPM-MEG also allows sensors to be positioned closer to the scalp with increased flexibility in the placement of sensors (Boto et al., 2016).”
Qi, S., Song, X., Jia, L., Duan, Z., Dai, Y., Zhang, J., & Ning, X. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2025.121078 · Cited by 11
“Here we chose a threshold of less than 50% shared variance as suggested by Boto et al. (2016), which is in fact a relatively lenient threshold.”
Towards a 384-channel magnetoencephalography system based on optically pumped magnetometers
Schofield, H., Hill, R. M., Rier, L., Kennett, E., Rivero, G. R., Gibson, J., Tyler, A. J., Tanner, Z., Worcester, F., Hayward, T., et al. (2025) · Imaging Neuroscience · doi:10.1162/imag.a.1042 · Cited by 13
“First, as sensors move closer to the head, field patterns become more focal ( Boto et al., 2016; Iivanainen et al., 2017; Tierney et al., 2022); if the density of sensors is insufficient, then the largest magnetic fields can be missed (i.e., the field pattern is spatially aliased).”
Self-citationSchneiderman, J. F., Ruffieux, S., Pfeiffer, C., & Riaz, B. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5_78 · Cited by 12
Ma, Y., Gao, Y., Wu, H., Liang, X., Li, Y., Lu, H., Liu, C.-Z., & Ning, X. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3381173 · Cited by 11
“…to the target brain regions for more precise measurement [6], [7], OPM-MEG can obtain higher signal amplitude, reconstruction accuracy, spatial resolution than SQUID-MEG [8], [9], and has the potential of measuring a wider range of disease entities and special populations such as infants [5], [10].”
BackgroundA modular optically pumped magnetometer system
Coussens, T., Gialopsou, A., Abel, C., Bason, M. G., James, T. M., Evans, W., Woodley, M. T. M., Nightingale, D., Nicolau, D., Page, L., et al. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad4e60 · Cited by 11
“OPMs offer reduced separation distances over SQUIDs, which is of particular interest for magnetoencephalography (MEG) [4–7], where OPM-MEG is able to offer an improved spatial [8, 9], and spatio-temporal [10] resolution.”
BackgroundSelf-citationRhodes, N., Rier, L., Boto, E., Hill, R. M., & Brookes, M. J. (2025) · Imaging Neuroscience · doi:10.1162/imag.a.8 · Cited by 15
Self-citationZhang, J., Meng, X., Han, T., Wei, X., Wang, L., Zhao, Y., Fu, G., Tian, N., Wang, Q., Qin, S., et al. (2023) · IET Nanodielectrics · doi:10.1049/nde2.12049 · Cited by 13
Optically Pumped Magnetometers for Practical MEG-Based Brain-Computer Interfacing
Wittevrongel, B., Holmes, N., Boto, E., Hill, R., Rea, M., Libert, A., Khachatryan, E., Bowtell, R., Brookes, M. J., & Van Hulle, M. M. (2021) · SpringerBriefs in Electrical and Computer Engineering · doi:10.1007/978-3-030-79287-9_4 · Cited by 9
Self-citationSERF-OPM Usability for MEG in Two-Layer-Shielded Rooms
Jazbinšek, V., Marhl, U., & Sander, T. H. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_10 · Cited by 12
Flow Rate Estimation Based on Magnetic Particle Detection Using a Miniatured High-Sensitivity OPM
Liu, Y., Huang, B., Li, J., Li, R., & Zhai, Y. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3565069 · Cited by 15
“Optically pumped magnetometer (OPM) arrays emerge as a promising choice and offer comparable sensitivity at low frequencies [13].”
MEG-Based Detection of Voluntary Eye Fixations Used to Control a Computer
Ovchinnikova, A. O., Vasilyev, A. N., Zubarev, I., Kozyrskiy, B. L., & Shishkin, S. L. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.619591 · Cited by 10
“…OPMs do not require expensive liquid helium to operate, making the system portable and less expensive while providing superior spatial resolution (Boto et al., 2016, 2017, 2018, 2019, 2020; Borna et al., 2017, 2020; Iivanainen et al., 2017, 2019; Hill et al., 2019, 2020; Limes et al., 2020;…”
BackgroundReal-Time Localization of OPMs in a Flexible Array During MEG Recordings
Gu, W., He, K., Ma, X., Li, D., Pang, W., Sheng, J., & Gao, J. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3346516 · Cited by 9
“A simulation study has shown that a 5% forward field error can negate the advantages of OPM-MEG over SQUID-MEG in terms of spatial resolution [13].”
BackgroundMethodHelbling, S. (2025) · Imaging Neuroscience · doi:10.1162/imag_a_00410 · Cited by 9
Yan, B., Peng, Y., Zhang, Y., Zhang, Y., Zhang, H., Cao, Y., Sun, C. K., & Ding, M. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2025.121262 · Cited by 8
“Furthermore, researchers have simulated OPM arrays with channel counts of 81, 275, 329, and 1293 based on international EEG layout standards (Boto et al., 2016).”
InfluentialOPM-MEG reveals dynamics of beta bursts underlying attentional processes in sensory cortex
Rivero, G., Tanner, Z., Rier, L., Hill, R. M., Shah, V., Rea, M., Doyle, C., Osborne, J., Bobela, D., Morris, P. G., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-08037-8 · Cited by 8
Self-citationImaging human cortical responses to intraneural microstimulation using magnetoencephalography
O’Neill, G. C., Watkins, R. H., Ackerley, R., Barratt, E. L., Sengupta, A., Asghar, M., Panchuelo, R. M. S., Brookes, M. J., Glover, P. M., Wessberg, J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.01.017 · Cited by 8
Self-citationMagnetically shielded high-resolution visual stimulation for OPM-MEG applications
Anders, P., Brickwedde, M., Voigt, J., Grent-‘t-Jong, T., Krüger, P., Haueisen, J., Uhlhaas, P. J., & Sander-Thoemmes, T. (2025) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/adb1eb · Cited by 9
Self-citationDu, P., Li, J., Yang, S., Wang, X.-T., Zhuo, Y., Wang, F., & Wang, R. (2019) · Chinese Physics B · doi:10.1088/1674-1056/28/4/040702 · Cited by 8
Sampling theory for spatial field sensing: Application to electro- and magnetoencephalographyPreprint
Iivanainen, J., Mäkinen, A., Zetter, R., Stenroos, M., Ilmoniemi, R. J., & Parkkonen, L. T. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1912.05401 · Cited by 7
“Simulations have shown that the closer proximity of the sensors to the brain improves spatial resolution of MEG and increases information about neuronal currents (Schneiderman, 2014; Boto et al., 2016; Iivanainen et al., 2017; Riaz et al., 2017).”
BackgroundHan, S., Wu, Y., Xiao, L., Jin, Z., & Chen, J. (2025) · Superconductor Science and Technology · doi:10.1088/1361-6668/ada82d · Cited by 6
Dynamic field nulling method for magnetically shielded room based on Smith predictor assisted GADRC
Zhao, J., Zhang, W., Sun, J., & Zhang, H. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116394 · Cited by 7
Magnetic field compensation method of dual-beam SERF atomic magnetometer under probing-axis bias
Song, X., Wu, D., Long, T., Wu, Z., & Jia, L. (2025) · Measurement · doi:10.1016/j.measurement.2025.118102 · Cited by 8
Evaluating the effect of OPM array errors on the multiple dipole localization accuracy of OPM-MEG
Qi, S., Ma, Y., Liu, Z. A., Jia, L., Wu, H., Song, X., & Ning, X. (2025) · Measurement · doi:10.1016/j.measurement.2025.117764 · Cited by 5
Biplanar Nulling Coil System for OPM-MEG Using Printed Circuit Boards
Jas, M., Kamataris, J., Matsubara, T., Dong, C., Motta, G., Sohrabpour, A., Ahlfors, S. P., Hämäläinen, M., Okada, Y. C., & Sundaram, P. (2025) · Sensors · doi:10.3390/s25092759 · Cited by 6
“OPMs have been used, for instance, in naturalistic paradigms involving movements [2] as well as in pediatric MEG studies [3].”
Microfabricated optically pumped magnetometer arrays for biomedical imaging
Perry, A. R., Sheng, D., Krzyzewski, S., Geller, S., & Knappe, S. A. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2261167 · Cited by 5
Gratifying Gizmos for Research and Clinical MEG
Jousmäki, V. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2021.814573 · Cited by 5
Optically Pumped Magnetometers for MEG
Knappe, S. A., Sander, T. H., & Trahms, L. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5_49 · Cited by 7
Microfabricated optically-pumped magnetometers for imaging applications
Knappe, S. A., Hughes, J. V., & Alem, O. (2023) · Optical and Quantum Sensing and Precision Metrology II · doi:10.1117/12.2657353 · Cited by 6
“It has also been predicted that this can lead to high reconstruction accuracy [44-47].”
BackgroundMapping neural signatures of face processing in young children: an OPM-MEG study
Safar, K., Vandewouw, M. M., Rhodes, N., Sato, J., & Taylor, M. J. (2025) · Social Cognitive and Affective Neuroscience · doi:10.1093/scan/nsaf076 · Cited by 8
The Mismatch Negativity Compared: EEG , SQUID ‐ MEG , and Novel 4Helium ‐ OPMs
Gutteling, T. P., Mattout, J., Daligault, S., Jung, J., Labyt, É., Schwartz, D., & Lecaignard, F. (2025) · Human Brain Mapping · doi:10.1002/hbm.70368 · Cited by 4
Gu, W., Li, D., & Gao, J. (2023) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2023.110010 · Cited by 4
Extended homogeneous field correction method based on oblique projection in OPM-MEG
Wang, F., Cao, F., Yu-jie, M., Zhao, R., Wang, R., An, N., Xiang, M., Wang, D., & Ning, X. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2024.120991 · Cited by 4
“OPM-MEG can reportedly increase signal amplitude by approximately five-fold and significantly enhance source reconstruction accuracy and spatial resolution, making OPM-MEG a potentially superior alternative to SQUID-MEG (Boto et al., 2016).”
Ramírez, A., Siegel, E. R., Qasim, A., Eswaran, H., & Escalona‐Vargas, D. (2026) · Heart Rhythm · doi:10.1016/j.hrthm.2026.06.013 · Cited by 3
Ruan, Y., Xiang, Z., Lu, G., Chen, Y., Liu, Y., Liu, F., Wang, J., Zhang, Y., Yao, J., Liu, Y., et al. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e31740 · Cited by 3
“With a volume of only 0.45 cm 3 , much smaller than SQUIDs magnetometers, each sensor can be arrayed according to different brain shapes for a closer fit to the human head, facilitating wearable implementation [30 – 32].”
BackgroundInfluentialShangguan, S., Dou, S., Wen, T., Han, B., Liu, X., & Feng, R. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3555727 · Cited by 4
“The optical pump magnetometer (OPM) is one type of ultrasensitive magnetic field sensor that is widely used in the MEG [6], [7].”
Marhl, U., Jodko-Władzińska, A., Brühl, R., Sander, T. H., & Jazbinšek, V. (2019) · International Convention on Information and Communication Technology, Electronics and Microelectronics · doi:10.23919/mipro.2019.8756998 · Cited by 3
Optically Pumped Magnetometers for MEG
Knappe, S. A., Sander, T. H., & Trahms, L. (2019) · Springer eBooks · doi:10.1007/978-3-319-62657-4_49-1 · Cited by 3
Dawson, R., O’Dwyer, C., Mrozowski, M. S., Ingleby, S. J., Griffin, P. F., & Riis, E. (2024) · Optical and Quantum Sensing and Precision Metrology II · doi:10.1117/12.3002678 · Cited by 5
“18 Developments in portable zero-field OPMs have improved source localisation 19 due to better signal coverage, 16,20,21 where the measurement of accurate magnetic field information underpins the accurate extraction of spatial and temporal information.”
BackgroundSchneiderman, J. F., Ruffieux, S., Pfeiffer, C., & Riaz, B. (2019) · Springer eBooks · doi:10.1007/978-3-319-62657-4_78-1 · Cited by 4
Jonany, V., Haslacher, D., Robinson, S. E., Sander, T. H., Zerfowski, J., Peekhaus, N., Krüger, P., & Soekadar, S. R. (2026) · Brain stimulation · doi:10.1016/j.brs.2026.103139 · Cited by 2
Self-citationZhang, M., Wang, Y., Li, P., Zhang, Y., & Xiang, M. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3604125 · Cited by 2
“Such evaluations can be carried out through various metrics, including matrix condition number [13], total information transmitted from the array [14], [15], spatial resolution [16], [17], and signal-to-noise ratio (SNR) [18], [19].”
Magnetic Source Localization: A Review of Methods and Applications
Zhang, X., Zhang, Y., & Xiang, M. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3635829 · Cited by 2
“Reconstruction accuracy of beamformer using simulated SQUID system and simulated optically pumped magnetometer (OPM) system [146]. proximity can cause intersensor interference.”
Marhl, U., Hren, R., Sander, T. H., & Jazbinšek, V. (2026) · Sensors · doi:10.3390/s26041292 · Cited by 3
“These sensors operate at room temperature and can be placed directly on the scalp, thereby increasing the signal-to-noise ratio (SNR) [4,5], improving spatial resolution [6], and enabling subject-specific sensor configurations [7–9].”
Effects of Magnetocardiography Array Errors on Cardiac Source Imaging
Zhang, M., Wang, Y., Li, P., Zhang, Y., Cui, Y., & Xiang, M. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3676206 · Cited by 2
“√ Two sources were considered resolvable if ρ 2 1 / 2, which corresponds to a shared variance of less than 50% between the two reconstructed signals [42].”
Spatial-Jitter Model for Magnetoencephalography Sensor Arrays
Iivanainen, J. (2026) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2026.3687982 · Cited by 3
“OPM-based arrays o ff er improvements over SQUID-arrays in terms of signal amplitude, spatial resolution of the measurements, as well as their information content [4], [5], [6], [7].”
An Integrated 64-Channel Optical-Fiber-Split OPM-MCG System
Lin, S., Ma, Y., Yuan, Z., Wang, Y., Zhai, Y., & Tang, J. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3701180 · Cited by 2
“Previous theoretical work predicted that OPM-based systems could surpass cryogenic MEG in multiple aspects, o ff ering significant gains in sensitivity, spatial resolution, and reconstruction accuracy [22].”
High-temperature superconducting magnetometers for on-scalp MEG
Ruffieux, S. (2020) · Chalmers Research (Chalmers University of Technology) · Cited by 3
Neural Spintronics: Noninvasive Augmentation of Brain Functions
Barnes, S. E., Opriș, I. C., Noga, B. R., Huang, S., & Zuo, F. (2021) · Contemporary clinical neuroscience · doi:10.1007/978-3-030-54564-2_20 · Cited by 2
On the clinical utility of on-scalp MEG: A modeling study of epileptic activity source estimation
Westin, K., Beniczky, S., Pfeiffer, C., Hämäläinen, M., & Lundqvist, D. (2023) · Clinical Neurophysiology · doi:10.1016/j.clinph.2023.10.006 · Cited by 2
Using a Limited Number of Sensors in MEG or the Feasibility of Partial Head Coverage OPM MEG
Marhl, U., Sander, T. H., & Jazbinšek, V. (2024) · International Convention on Information and Communication Technology, Electronics and Microelectronics · doi:10.1109/mipro60963.2024.10569644 · Cited by 2
“Due to the nature of the magnetic field, by bringing the sensors closer to the sources, the SNR is significantly improved [3], [4].”
Background"A Review of the Effects of Pharmaceuticals on Marine Invertebrates"
El-Din, M. I. S. (2023) · Biomedical Journal of Scientific & Technical Research · doi:10.26717/bjstr.2023.48.007727 · Cited by 2
Dynamic causal modeling of layered magnetoencephalographic event-related responsesPreprint
Ihle, S. J., Bonaiuto, J. J., Bestmann, S., Stephan, K. E., Barnes, G. R., & Heinzle, J. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.07.20.208504 · Cited by 2
Self-citationMagnetoencephalography Without a Shielded RoomPreprint
Bezsudnova, Y., Alexander, N., Mellor, S., Mitryukovskiy, S. I., Romain, R., Palacios-Laloy, A., Barnes, G. R., Callaghan, M. F., & Tierney, T. M. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.08.06.743270 · Cited by 3
“Their lightweight, cryogen-free design simplifies siting requirements, and means that they can be placed much closer to the brain, boosting signal amplitude 9 .”
Self-citationLyons, K., Ho, W., Saljoughi, S., Owen, A. M., Stevenson, R., & Stojanoski, B. B. (2026) · Developmental Neuroscience · doi:10.1159/dne/aclag002 · Cited by 1
Carreno, C. A., Evans, M. E., Lockhart, B. K., Chinaka, O., Katz, B., Bell, M. A., & Howell, B. (2024) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2024.101481 · Cited by 1
MOTUM: A system for Motion Online Tracking Under MRI
Bencivenga, F., Tani, M., Vyas, K., Giove, F., Gazzitano, S., & Galati, G. (2025) · Imaging Neuroscience · doi:10.1162/imag.a.1081 · Cited by 1
Adaptive helmet design for optically pumped magnetometry
Hristova, I., Funk, F., van Schaik, B., Clercx, F., Ooms, A., Bosma, H., Sabater, D. Z., Nonnekes, A., Wang, P., & Hillebrand, A. (2025) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2025.100949 · Cited by 1
Matsubara, T., Sohrabpour, A., Ahlfors, S. P., Jas, M., Samuelsson, J. G., Sundaram, P., & Stufflebeam, S. M. (2026) · NeuroImage · doi:10.1016/j.neuroimage.2026.121930 · Cited by 2
“…across cerebellar and cerebral regions provides and important insight: for deep sources, scalp-source distance is a dominant limiting factor, and reducing sensor distance by bringing sensors closer to the scalp alone does not significantly improve SNR (Boto et al., 2016; Iivanainen et al., 2017).”
Beta-band dynamics during a naturalistic motor task: An OPM-MEG study
Gibson, J., Fildes, J., Kirby, A., Holmes, N., Rier, L., Mullinger, K. J., Ison, M. J., Morris, P. G., Boto, E., Hill, R. M., et al. (2026) · Imaging Neuroscience · doi:10.1162/imag.a.1405 · Cited by 1
Self-citationMagnetic Field Imaging with Microfabricated Optically-Pumped Magnetometer Arrays
Nardelli, N. V., Krzyzewski, S., Korenko, B., Romanov, G., Hughes, J. V., Alem, O., & Knappem, S. (2019) · Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC) · doi:10.1109/cleoe-eqec.2019.8872678 · Cited by 1
Gaetz, W. C., Graci, V., Falciani, C., Sanders, O., & Prosser, L. A. (2022) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2022.109675 · Cited by 1
Arcara, G., Pellegrino, G., Pascarella, A., Mantini, D., Kobayashi, E., & Jerbi, K. (2023) · Neuromethods · doi:10.1007/978-1-0716-3545-2_8 · Cited by 2
Early insights into eyeblink conditioning using optically pumped magnetometer-based MEG
Lin, C., Tierney, T. M., Mellor, S., O’Neill, G. C., Bestmann, S., Barnes, G. R., & Miall, R. C. (2025) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2025.1638751 · Cited by 2
Self-citationExcitatory-inhibitory balance in children with 22q11.2 deletion syndrome
Doherty, J. L. (2019) · ORCA Online Research @Cardiff (Cardiff University)
Neuroimaging of binocular vision in human amblyopia
Lygo-Frett, F. (2019) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York) · Cited by 2
Constantin, F. L. (2020) · Joint Conference of the IEEE International Frequency Control Symposium and International Symposium on Applications of Ferroelectrics (IFCS-ISAF) · doi:10.1109/ifcs-isaf41089.2020.9234880
“INTRODUCTION Precise sensing of the magnetic fields has applications in geophysics [1], medical imaging [2,3], and precision physics measurements [4].”
BackgroundBrain-imaging based methodology for OPM sensor placement
Duque‐Muñoz, L. (2019) · Institutional Repository University of Antioquia (University of Antioquia)
Neural Synchrony in Neuromagnetic Signals and the Role of Alpha Oscillations for Working Memory
Wianda, E. (2019) · TSpace (University of Toronto) · Cited by 1
Westin, K., Beniczky, S., Hämäläinen, M., & Lundqvist, D. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4019388
On-scalp magnetoencephalography: an innovative technology for patients with neurological pathologies
Feys, O., Tombroff, L., & Tiège, X. D. (2024) · Revue Medicale de Bruxelles · doi:10.30637/2024.23-048
Non-invasive mapping of the temporal processing hierarchy in the human visual cortex
Eickhoff, K., Hillebrand, A., Knapen, T. H. J., de Jong, M. C., & Dumoulin, S. O. (2026) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1014434 · Cited by 1
Seasonal dynamics of nitrification in the water column of marine Lake GrevelingenPreprint
Dotsios, N., Venetz, J., Żygadłowska, O. M., Lenstra, W. K., van Helmond, N. A. G. M., Wallenius, A. J., Klomp, R., Slomp, C. P., Jetten, M. S. M., van Kessel, M. A. H. J., et al. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.06.29.662106
Waitt, A. E. (2022) · Nottingham ePrints (University of Nottingham) · Cited by 1
Uporaba optičnih magnetometrov v magnetoencefalografiji
Marhl, U. (2023) · University of Maribor digital library (University of Maribor)
Design and fabrication for next generation Magnetoencephalography
Hill, R. (2021) · Nottingham ePrints (University of Nottingham) · Cited by 2
Optical transformation based magnetic field guide for optically pumped magnetometers
Wang, S. (2023) · UPCommons institutional repository (Universitat Politècnica de Catalunya)
Towards naturalistic scanning environments for wearable magnetoencephalography
Rea, M. (2023) · Nottingham ePrints (University of Nottingham)
Sistema de MEG con Sensores OPM en Colombia Fase 1: diseño e Implementación
López Jiménez, J. D. (2025) · EIA University Library (EIA University)
Realising the potential of wearable magnetoencephalography
Rivero, G. R. (2025) · Nottingham ePrints (University of Nottingham) · doi:10.17639/11303
A corrected image method for uniform coil design with size adaptability in magnetic shielding rooms
Sun, J., Shi, Y., Gan, Z., Zhou, W., Feng, S., & Han, B. (2026) · Measurement · doi:10.1016/j.measurement.2026.121314
Reliability and signal comparison of OPM-MEG, fMRI & iEEG in a repeated movie viewing paradigm
Christiano, O. R., & Michelmann, S. (2026) · Imaging Neuroscience · doi:10.1162/imag.a.1218
Effects of Inverse Solutions and Calibration Errors on Localization Performance of OPM-MEG
Qi, S., Cui, S., Jia, L., Long, T., Song, X., & Ning, X. (2026) · Annals of Biomedical Engineering · doi:10.1007/s10439-026-04133-6
Yan, B., Ji, J., Peng, Y., Cao, Y., Zhang, H., Zhang, Y., Zhang, Y., Niu, Y., Sun, C., & Ding, M. (2026) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2026.05.001
Kowalczyk, A., Bezsudnova, Y., Barontini, G., & Jensen, O. B. (2026) · University of Birmingham Research Portal (University of Birmingham) · doi:10.25500/edata.bham.00001639
Decoding Visual Pathway Dysfunction with SERF-MEG: A Study in Patients with Optic Neuropathy
Wang, H., Qi, Y., Lou, Y., Zhang, X., & Song, X. (2026) · Bioengineering · doi:10.3390/bioengineering13060694
Liu, Y., Song, M. K., Huang, B., An, Y., Jin, T., Liu, Z., & Zhai, Y. (2026) · Advanced Quantum Technologies · doi:10.1002/qute.70380
“…fields in one axis and, in general, therefore, triaxial magnetometers have received widespread attention due to their capability of measuring the total magnetic field vector information, which is vital for magnetic source imaging [ 7, 8 ], magnetic anomaly detection [ 13 ], and so on [ 14, 15 ].”
Sun, J., Shi, Y., Ji, A., Feng, S., & Zhou, W. (2026) · Youth Academic Annual Conference of Chinese Association of Automation (YAC) · doi:10.1109/yac71005.2026.11616013
“These applications typically require a stable and highly uniform magnetic field environment to ensure reliable sensor performance [6], [7].”
A Novel Modulation Method for Superconducting--TMR Hybrid Magnetic Sensor Based on Resonance
Han, S., Wu, Y., Zou, X., Xiao, L., Jin, Z., Zhang, C., & Chen, J. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3718596
“This limitation has, to some extent, impeded their practical applications [6], [7], [8], [9], [10], [11], [12], [13], [14].”
Signal-to-noise ratio of event-related fields in on-scalp and off-scalp MEGPreprint
Jas, M., Matsubara, T., Sohrabpour, A., Sundaram, P., Mody, M., & Ahlfors, S. P. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.08.17.744953
“…participants, anatomically more realistic head models, and advanced noise reduction and other signal processing techniques including beamformers (Boto et al., 2016) to dissociate signal and noise components, could help to further elucidate the properties and capabilities of the different types…”
Modular Arrays for High Precision Wearable MEGPreprint
Alexander, N., Mariola, A., Puvvada, S., Bezsudnova, Y., Tierney, T. M., Barnes, G. R., & Callaghan, M. F. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.08.19.745485
“For example, by including temporal and face measurements (Feys et al., 2025; Tierney et al., 2021) to increase hippocampal SNR.”
InfluentialSelf-citationCompact all-optical atomic magnetometer for operation in unshielded environments
Lyu, Y., Xiao, W., Li, B. G., Luo, Y., Mao, X., Wu, T., & Guo, H. M. (2026) · Review of Scientific Instruments · doi:10.1063/5.0335753
Neumann, Y., Gross, O., Schabes, T., DeMalach, N., & Kalyuzhny, M. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.09.07.749828
Comparing advanced interference suppression algorithms for OPM-MEGPreprint
Pfeiffer, C., & Lundqvist, D. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.09.08.750027
“Simulations have shown higher sensitivity, more extracted information and higher spatial precision compared to conventional MEG (Boto et al., 2016; Iivanainen et al., 2017; Riaz et al., 2017).”
Metadata
- Authors
- Boto, E., Bowtell, R., Krüger, P., Fromhold, T. M., Morris, P. G., Meyer, S. S., Barnes, G. R., & Brookes, M. J.
- Affiliations
- University of Nottingham (GB)
- Wellcome Centre for Human Neuroimaging (GB)
- Corresponding author
- Brookes, Matthew J.
- ORCID
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2016-08-26
- Volume
- 11
- Issue
- 8
- Pages
- e0157655
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC5001648
- OpenAlex
- W2512628654
- Cited by
- 194
- References
- 64
- Citations by year
- 2026: 23 · 2025: 26 · 2024: 19 · 2023: 26 · 2022: 22 · 2021: 18 · 2020: 16 · 2019: 23 · 2018: 7 · 2017: 11 · 2016: 3
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Repository@Nottingham (University of Nottingham) (publishedVersion, other-oa)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
- Sussex Research Online (University of Sussex) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- UCL Discovery (University College London) (submittedVersion)
- Figshare (submittedVersion, cc-by)
- Funders
- Medical Research Council (GB) New Investigator Grant (MR/M006301/1)
- Engineering and Physical Sciences Research Council (GB) UK National Quantum Technology Hub for Sensors and Metrology Grant (EP/M013294/1)
- Medical Research Council and Engineering and Physical Sciences Research Council (GB) Partnership Grant (MR/K6010/86010/1)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- magnetoencephalography, optically pumped magnetometers, superconducting magnetometer, beamforming, signal-to-noise ratio, sensor sensitivity, spatial resolution, reconstruction accuracy, brain magnetic fields
- MeSH terms
- Adult, Algorithms, Brain, Brain Mapping, Computer Simulation, Electrophysiology, Equipment Design, Humans, Image Processing, Computer-Assisted, Magnetoencephalography, Phantoms, Imaging, Optics and Photonics, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.