CoChat

Effectiveness of screening for atrial fibrillation and its determinants. A meta-analysis

Open access
Petryszyn, Pawel, Niewinski, Piotr, Staniak, Aleksandra, Piotrowski, Patryk, Well, Anna, Well, Michal, Jeskowiak, Izabela, Lip, Gregory, Ponikowski, Piotr · 2019 · PLOS ONE
Cited by 57

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Many atrial fibrillation patients eligible for oral anticoagulants are unaware of the presence of AF, and improved detection is necessary to facilitate thromboprophylaxis against stroke. OBJECTIVE: To assess the effectiveness of screening for AF compared to no screening and to compare efficacy outcomes of different screening strategies. MATERIALS AND METHODS: Cochrane Central Register of Controlled Trials, EMBASE and MEDLINE from Jan 1, 2000 -Dec 31, 2015 were searched. Studies employing systematic or opportunistic screening and using ECG or pulse palpation in populations age ≥40 years were included. Data describing study and patient characteristics and number of patients with new AF were extracted. The outcome was the incidence of previously undiagnosed AF. RESULTS: We identified 25 unique (3 RCTs and 22 observational) studies (n = 88 786) from 14 countries. The incidence of newly detected AF due to screening was 1.5% (95% CI 1.1 to 1.8%). Systematic screening was more effective than opportunistic: 1.8% (95% CI 1.4 to 2.3%) vs. 1.1% (95% CI 0.6 to 1.6%), p<0.05, GP-led screening than community based: 1.9% (95% CI 1.4 to 2.4%) vs. 1.1% (95% CI 0.7 to 1.6%), p<0.05, and repeated heart rhythm measurements than isolated assessments of rhythm: 2.1% (95% CI 1.5-2.8) vs. 1.2% (95% CI 0.8-1.6), p<0.05. Only heart rhythm measurement frequency had statistical significance in a multivariate meta-regression model (p<0.05). CONCLUSIONS: Active screening for AF, whether systematic or opportunistic, is effective beginning from 40 years of age. The organisation of screening process may be more important than technical solutions used for heart rhythm assessment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0213198

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 57

Metadata

Authors
Petryszyn, P., Niewinski, P., Staniak, A., Piotrowski, P., Well, A., Well, M., Jeskowiak, I., Lip, G., & Ponikowski, P.
Venue
PLOS ONE
Published
2019-03-20
Volume
14
Issue
3
Pages
e0213198
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2922733397
Cited by
57
References
14
FWCI
2.08
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effectiveness of screening for atrial fibrillation and its determinants. A meta-analysis. https://app.cochat.ai/papers/10.1371/journal.pone.0213198
The paper
Petryszyn, P., Niewinski, P., Staniak, A., Piotrowski, P., Well, A., Well, M., Jeskowiak, I., Lip, G., & Ponikowski, P. (2019). Effectiveness of screening for atrial fibrillation and its determinants. A meta-analysis. PLOS ONE. https://doi.org/10.1371/journal.pone.0213198

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.