Cited by 494Reliability and Agreement in MeasurementSports Dynamics and BiomechanicsLower Extremity Biomechanics and Pathologies

Validity and reliability of the Kinovea program in obtaining angles and distances using coordinates in 4 perspectives

Open access
Puig-Diví, Albert, Escalona-Marfil, Carles, Padullés-Riu, Josep Maria, Busquets, Albert, Padullés-Chando, Xavier, Marcos-Ruiz, Daniel·2019·PLoS ONE

Abstract

An objective analysis of the human movement can help both clinical assessment and sports performance. Kinovea is a free 2D motion analysis software that can be used to measure kinematic parameters. This low-cost technology has been used in sports sciences, as well as in the clinical and research fields. One interesting tool is that it can measure an object (or person) passing in front of the camera, taking into account the perspective between the camera and the recorded object. Although it has been validated as a tool to assess time-related variables, few studies assessed its validity compared to a Gold Standard; furthermore, its reliability in different perspectives has not been previously assessed. The main objective of this study is to determine the validity of the Kinovea software compared to AutoCAD, and its intra and inter-rater reliability in obtaining coordinates data; a second objective is to compare their results at 4 different perspectives (90°, 75°, 60° and 45°) and to assess the inter and intra rater reliability at each perspective. For this purpose, a wire structure figure in the shape of a human lower limb was designed and measured in AutoCAD; it was then recorded during a pendular motion with a video-camera placed at distance of 5 m and analyzed with Kinovea in the 4 perspectives (90°, 75°, 60° and 45°). Each frame was examined by three observers who made two attempts. A multiple approach was applied involving the analysis of the systematic error, with a two-way ANOVA 2x4; the relative reliability with Intraclass Correlation Coefficient (ICC) and the Coefficient of Variance (CV) (95% confidence interval); and the absolute reliability with the Standard Error (SE). The results indicate that the Kinovea software is a valid and reliable tool that is able to measure accurately at distances up to 5 m from the object and at an angle range of 90°-45°. Nevertheless, for optimum results an angle of 90° is suggested.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0216448

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The validity and reliability of the Kinovea software was previously studied.

    “The validity and reliability of the Kinovea software was previously studied (34–36).”
  • Positioning the head near the edges of the camera's field of view may have increased errors due to parallax or spherical lens distortion compared to segments located closer to the center of the frame.

    “positioning the head near the edges of the camera’s field of view may have increased errors due to parallax or spherical lens distortion compared to the segments located closer to the center of the frame (e.g., pelvis and knee) [48,57].”

    From Intra-Rater and Test–Retest Reliability of Kinovea for the Kinematic Analysis of Squatting in Healthy Active Women (2026) · cites this paper as [48]

    The Results (Data analysis; page not provided) compare measurement error across camera perspectives, not across positions within the frame. Searches for parallax, lens distortion, and edge-versus-center placement found no passage addressing whether a head near the frame edge would have greater error than a pelvis or knee near its center. (LLM, conf=0.74)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 39 references couldn’t be matched to a known paper.

Research works printed but not linked: 3

  1. [18]Ramon Suarez G, Gaviria Alzate S, Teller Carreno DC, Calderon Rojas M, Ruiz Correa V. Evaluation scale of visual and auditive action-reaction times in youth karate athletes of Antioquia, Colombia. Viref Rev Educ Fis. 2016; 5(1): 1– 16.
  2. [23]Rebolledo Uribe JP, Pincheira Barbé PA, Bittner Schmidt V, Frugone Zambra RE. Occlusal plane inclination in children between 9 and 10 years of age with postural asymmetry. A study on the frontal plane. Rev Fac Odontol Univ Antioquia. 2012; 24(1): 76– 84.
  3. [43]Eltoukhy M, Asfour S, Thompson C, Latta L. Evaluation of the performance of digital video analysis of human motion: Dartfish tracking system. Int J Sci Eng Res. 2012; 3: 1– 6.

Cited by

Sorted by citations

Authors
Puig-Diví, A., Escalona-Marfil, C., Padullés-Riu, J. M., Busquets, A., Padullés-Chando, X., & Marcos-Ruiz, D.
Affiliations
  • Universitat Ramon Llull (ES)
  • Institut Nacional d'Educació Física de Catalunya (ES)
  • Universitat de Girona (ES)
Venue
PLoS ONE
Published
2019-06-05
Volume
14
Issue
6
Pages
e0216448
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2948315428
Cited by
434
References
39
Citations by year
2026: 69 · 2025: 80 · 2024: 69 · 2023: 70 · 2022: 65 · 2021: 47 · 2020: 31 · 2019: 3
FWCI
24.42
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (acceptedVersion, cc-by)
  • Universitat de Girona Digital Repository (Universitat de Girona) (acceptedVersion, cc-by)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Universitat de Girona Digital Repository (Universitat de Girona) (submittedVersion, cc-by)
  • Figshare (submittedVersion, cc-by)
  • RECERCAT (Consorci de Serveis Universitaris de Catalunya) (submittedVersion, cc-by)
Funders
Institut Nacional d'Educacio Fisica de Catalunya, Generalitat de Catalunya
Topics
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
  • Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
  • Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
Keywords
Kinovea, video-based motion analysis, measurement validity, inter-rater reliability, intra-rater reliability, camera angles, coordinate measurement, pendulum motion, lower limb kinematics, systematic errors
MeSH terms
Biomechanical Phenomena, Gait, Humans, Movement, Software, Reproducibility of Results, Range of Motion, Articular

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review