Machine learning-based glucose prediction with use of continuous glucose and physical activity monitoring data: The Maastricht Study
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Background: Closed-loop insulin delivery systems, which integrate continuous glucose monitoring (CGM) and algorithms that continuously guide insulin dosing, have been shown to improve glycaemic control. The ability to predict future glucose values can further optimize such devices. In this study, we used machine learning to train models in predicting future glucose levels based on prior CGM and accelerometry data. Methods: We used data from The Maastricht Study, an observational population‐based cohort that comprises individuals with normal glucose metabolism, prediabetes, or type 2 diabetes. We included individuals who underwent >48h of CGM (n = 851), most of whom (n = 540) simultaneously wore an accelerometer to assess physical activity. A random subset of individuals was used to train models in predicting glucose levels at 15- and 60-minute intervals based on either CGM data or both CGM and accelerometer data. In the remaining individuals, model performance was evaluated with root-mean-square error (RMSE), Spearman’s correlation coefficient (rho) and surveillance error grid. For a proof-of-concept translation, CGM-based prediction models were optimized and validated with the use of data from individuals with type 1 diabetes (OhioT1DM Dataset, n = 6). Results: Models trained with CGM data were able to accurately predict glucose values at 15 (RMSE: 0.19mmol/L; rho: 0.96) and 60 minutes (RMSE: 0.59mmol/L, rho: 0.72). Model performance was comparable in individuals with type 2 diabetes. Incorporation of accelerometer data only slightly improved prediction. The error grid results indicated that model predictions were clinically safe (15 min: >99%, 60 min >98%). Our prediction models translated well to individuals with type 1 diabetes, which is reflected by high accuracy (RMSEs for 15 and 60 minutes of 0.43 and 1.73 mmol/L, respectively) and clinical safety (15 min: >99%, 60 min: >91%). Conclusions: Machine learning-based models are able to accurately and safely predict glucose values at 15- and 60-minute intervals based on CGM data only. Future research should further optimize the models for implementation in closed-loop insulin delivery systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
Learning representations by back-propagating errors
Rumelhart, D. E., Hinton, G. E., & Williams, R. J. (1986) · Nature · doi:10.1038/323533a0 · Cited by 31,892
Empirical Evaluation of Gated Recurrent Neural Networks on Sequence Modeling
Chung, J., Gulcehre, C., Cho, K., & Bengio, Y. (2014) · arXiv · doi:10.48550/arxiv.1412.3555 · Cited by 11,008
Bidirectional recurrent neural networks
Schuster, M., & Paliwal, K. K. (1997) · IEEE Transactions on Signal Processing · doi:10.1109/78.650093 · Cited by 10,172
Fundamentals of Recurrent Neural Network (RNN) and Long Short-Term Memory (LSTM) Network
Sherstinsky, A. (2020) · Physica D: Nonlinear Phenomena · doi:10.1016/j.physd.2019.132306 · Cited by 5,680
The Emerging Risk Factors Collaboration (2010) · The Lancet · doi:10.1016/s0140-6736(10)60484-9 · Cited by 5,125
Zhou, B., Lu, Y., Hajifathalian, K., Bentham, J., Di Cesare, M., Danaei, G., Bixby, H., Cowan, M., Ali, M., Taddei, C., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)00618-8 · Cited by 4,311
Mechanisms of Diabetic Complications
Forbes, J. M., & Cooper, M. E. (2013) · Physiological Reviews · doi:10.1152/physrev.00045.2011 · Cited by 2,890
Bidirectional LSTM Networks for Improved Phoneme Classification and Recognition
Graves, A., Fernández, S., & Schmidhuber, J. (2005) · Lecture Notes in Computer Science · doi:10.1007/11550907_126 · Cited by 925
6. Glycemic Targets: Standards of Medical Care in Diabetes—2019
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s006 · Cited by 655
Cited by
Wearable chemical sensors for biomarker discovery in the omics era
Sempionatto, J. R., Lasalde-Ramírez, J. A., Mahato, K., Wang, J., & Gao, W. (2022) · Nature Reviews Chemistry · doi:10.1038/s41570-022-00439-w · Cited by 613
Applications of artificial intelligence and machine learning in prediabetes: a scoping review.
Lalani, B., Herur, R., Zade, D., Collins, G., Dishong, D. M., Mehta, S., Shim, J., Valdez, Y., & Mathioudakis, N. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251351995 · Cited by 11
Gauthier, P., Desir, C., Plombas, M., Joffray, E., Benhamou, P., & Borel, A. (2023) · Journal of Sleep Research · doi:10.1111/jsr.13799 · Cited by 10
“The contribution of the accelerometer was negligible in improving the algorithm, which seems to be confirmed by the results presented here (van Doorn et al., 2021).”
ResultBurks, J. H., Joe, L., Kanjaria, K., Monsivais, C., O'laughlin, K., & Smarr, B. L. (2025) · PLOS Digital Health · doi:10.1371/journal.pdig.0000815 · Cited by 5
Metadata
- Authors
- van Doorn, W. P. T. M., Foreman, Y. D., Schaper, N. C., Savelberg, H. H. C. M., Koster, A., van der Kallen, C. J. H., Wesselius, A., Schram, M. T., Henry, R. M. A., Dagnelie, P. C., de Galan, B. E., Bekers, O., Stehouwer, C. D. A., Meex, S. J. R., & Brouwers, M. C. G. J.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2021-06-24
- Volume
- 16
- Issue
- 6
- Pages
- e0253125
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W3175738155
- Cited by
- 104
- References
- 17
- FWCI
- 7.48
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Machine learning-based glucose prediction with use of continuous glucose and physical activity monitoring data: The Maastricht Study. https://app.cochat.ai/papers/10.1371/journal.pone.0253125
- The paper
- van Doorn, W. P. T. M., Foreman, Y. D., Schaper, N. C., Savelberg, H. H. C. M., Koster, A., van der Kallen, C. J. H., Wesselius, A., Schram, M. T., Henry, R. M. A., Dagnelie, P. C., de Galan, B. E., Bekers, O., Stehouwer, C. D. A., Meex, S. J. R., & Brouwers, M. C. G. J. (2021). Machine learning-based glucose prediction with use of continuous glucose and physical activity monitoring data: The Maastricht Study. PLOS ONE. https://doi.org/10.1371/journal.pone.0253125
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.