The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Evaluation of Imprecision for Cardiac Troponin Assays at Low-Range Concentrations
Abstract
Background: The European Society of Cardiology/American College of Cardiology Committee for the Redefinition of Myocardial Infarction (MI) has recommended that an increased cardiac troponin should be defined as a measurement above the 99th percentile value of the reference group. A total imprecision (CV) at the decision limit of ≤10% is recommended. However, peer-reviewed data on assay imprecision are lacking. The purpose of this study was to construct the clinically relevant imprecision profiles for each of the commercially available cardiac troponin assays. Pools of human sera containing cardiac troponin concentrations around the MI decision limit were assessed to identify the lowest concentration associated with a 10% CV. Methods: Eight serum pools targeting different concentrations of cardiac troponin (I and T) were prepared and stored at −70 °C until usage. The cardiac troponin measurement protocol consisted of two replicates per specimen per run, and one run per day for 20 days, using two reagent lots and three calibrations. Manufacturers of each cardiac troponin assay directly performed the measurements. Data analysis for each assay was centralized and performed according to the NCCLS EP5-A guideline. Results: The lowest concentrations (μg/L) providing a 10% CV were as follows: AxSYM, 1.22; ACS:180, 0.37; Centaur, 0.33; Immuno 1, 0.34; Access, 0.06; Vidas, 0.36; Liaison, 0.065; Dimension, 0.26; Opus, 0.90; Stratus CS, 0.10; Immulite, 0.32; Vitros ECi, 0.44; Elecsys, 0.04; AIA 21, 0.09. Conclusion: No cardiac troponin assay was able to achieve the 10% CV recommendation at the 99th percentile reference limit defined by the manufacturer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
National Committee for Clinical Laboratory Standards
Bruck, E. (1980) · Pediatrics · doi:10.1542/peds.65.1.187 · Cited by 14,751
Antman, E., Bassand, J.-P., Klein, W., Ohman, M., Lopez Sendon, J. L., Rydén, L., Simoons, M., & Tendera, M. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00804-4 · Cited by 4,821
Wu, A. H., Apple, F. S., Gibler, W. B., Jesse, R. L., Warshaw, M. M., & Valdes, R. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.7.1104 · Cited by 662
Self-citationMorrow, D. A. (2001) · JAMA · doi:10.1001/jama.286.19.2405 · Cited by 656
It’s Time for a Change to a Troponin Standard
Jaffe, A. S., Ravkilde, J., Roberts, R., Naslund, U., Apple, F. S., Galvani, M., & Katus, H. (2000) · Circulation · doi:10.1161/01.cir.102.11.1216 · Cited by 643
Self-citationApple, F. S., Wu, A. H. B., & Jaffe, A. S. (2002) · American Heart Journal · doi:10.1067/mhj.2002.124048 · Cited by 397
Self-citationLindahl, B., Diderholm, E., Lagerqvist, B., Venge, P., & Wallentin, L. C. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01501-7 · Cited by 281
Venge, P., Lagerqvist, B. O., Diderholm, E., Lindahl, B., & Wallentin, L. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02271-3 · Cited by 159
Myocardial Infarction Redefined: Role of Cardiac Troponin Testing
Apple, F. S., & Wu, A. H. B. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.3.377 · Cited by 159
Self-citationFerguson, J., Beckett, G. J., Stoddart, M., Walker, S. W., & Fox, K. A. A. (2002) · Heart · doi:10.1136/heart.88.4.343 · Cited by 143
Cited by
Universal Definition of Myocardial Infarction
Thygesen, K., Alpert, J. S., White, H. D., TASK FORCE MEMBERS: Chairpersons: Kristian Thygesen (Denmark), J. S. A. (., Biomarker Group: Allan S. Jaffe, C. (., ECG Group: Bernard Chaitman, C.-O. (., Imaging Group: Richard Underwood, C. (., Intervention Group: Jean-Pierre Bassand, C.-O. (., Clinical Investigation Group: Paul W. Armstrong, C. (., Global Perspective Group: Philip A. Poole-Wilson, C. (., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.187397 · Cited by 4,230
Task Force Members, Thygesen, K., Alpert, J. S., White, H. D., Biomarker Group, Jaffe, A. S., Apple, F. S., Galvani, M., Katus, H. A., Newby, L. K., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm355 · Cited by 2,541
Self-citationAnderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.181940 · Cited by 1,853
Universal Definition of Myocardial Infarction
Thygesen, K., Alpert, J. S., & White, H. D. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.011 · Cited by 1,618
Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.02.013 · Cited by 1,510
Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.01.014 · Cited by 960
Troponin: the biomarker of choice for the detection of cardiac injury
Babuin, L., & Jaffe, A. S. (2005) · Canadian Medical Association Journal · doi:10.1503/cmaj.050141 · Cited by 686
Biomarkers in Acute Cardiac Disease
Jaffe, A. S., Babuin, L., & Apple, F. S. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.02.056 · Cited by 639
Self-citationUNIVERSAL DEFINITION OF MYOCARDIAL INFARCTION
Thygesen, K., Alpert, J., & White, H. (2008) · Rational Pharmacotherapy in Cardiology · doi:10.20996/1819-6446-2008-4-5-91-105 · Cited by 525
Wright, R. S., Anderson, J. L., Adams, C. D., Bridges, C. R., Casey, D. E., Ettinger, S. M., Fesmire, F. M., Ganiats, T. G., Jneid, H., Lincoff, A. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.02.011 · Cited by 516
Troponin Elevation in Heart Failure
Kociol, R. D., Pang, P. S., Gheorghiade, M., Fonarow, G. C., O'Connor, C. M., & Felker, G. M. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.016 · Cited by 443
Newby, L. K., Jesse, R. L., Babb, J. D., Christenson, R. H., De Fer, T. M., Diamond, G. A., Fesmire, F. M., Geraci, S. A., Gersh, B. J., Larsen, G. C., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.08.969 · Cited by 402
Self-citationMulticenter analytical evaluation of a high-sensitivity troponin T assay
Saenger, A. K., Beyrau, R., Braun, S., Cooray, R., Dolci, A., Freidank, H., Giannitsis, E., Gustafson, S., Handy, B., Katus, H., et al. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.12.034 · Cited by 376
Self-citationKhan, N. A., Hemmelgarn, B. R., Tonelli, M., Thompson, C. R., & Levin, A. (2005) · Circulation · doi:10.1161/circulationaha.105.560128 · Cited by 351
Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318212bb8b · Cited by 343
Giannitsis, E., Becker, M., Kurz, K., Hess, G., Zdunek, D., & Katus, H. A. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.134460 · Cited by 332
NACB Writing Group Members, Apple, F. S., Jesse, R. L., Newby, L. K., Wu, A. H. B., & Christenson, R. H. (2007) · Circulation · doi:10.1161/circulationaha.107.182881 · Cited by 300
Self-citationMingels, A., Jacobs, L., Michielsen, E., Swaanenburg, J., Wodzig, W., & van Dieijen-Visser, M. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.106427 · Cited by 295
Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.02.028 · Cited by 283
Sabatine, M. S., Morrow, D. A., de Lemos, J. A., Jarolim, P., & Braunwald, E. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn504 · Cited by 277
2007 WRITING COMMITTEE MEMBERS, Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31828478ac · Cited by 272
NACB WRITING GROUP MEMBERS, Apple, F. S., Jesse, R. L., Newby, L. K., Wu, A. H. B., Christenson, R. H., NACB COMMITTEE MEMBERS, Christenson, R. H., Apple, F. S., Cannon, C. P., et al. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.084715 · Cited by 258
Self-citationGoodacre, S., Bradburn, M., Fitzgerald, P., Cross, E., Collinson, P., Gray, A., & Hall, A. (2011) · Health Technology Assessment · doi:10.3310/hta15230 · Cited by 64
Metadata
- Authors
- Panteghini, M., Pagani, F., Yeo, K.-T. J., Apple, F. S., Christenson, R. H., Dati, F., Mair, J., Ravkilde, J., Wu, A. H. B., & the Committee on Standardization of Markers of Cardiac Damage of the IFCC
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-02-01
- Volume
- 50
- Issue
- 2
- Pages
- 327-332
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2122563040
- Cited by
- 368
- References
- 17
- FWCI
- 27.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.