Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 332

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

High-Sensitivity Cardiac Troponin T for Early Prediction of Evolving Non–ST-Segment Elevation Myocardial Infarction in Patients with Suspected Acute Coronary Syndrome and Negative Troponin Results on Admission

Giannitsis, Evangelos, Becker, Meike, Kurz, Kerstin, Hess, Georg, Zdunek, Dietmar, Katus, Hugo A · 2010 · Clinical Chemistry

Abstract

Background: We sought to determine the diagnostic performance of the new high-sensitivity cardiac troponin T (hs-cTnT) assay for early detection of non–ST-segment myocardial infarction (NSTEMI) in patients with acute coronary syndrome. Methods: We enrolled patients with retrospectively confirmed unstable angina or NSTEMI and an initially negative cTnT concentration and compared the performance of baseline concentrations and serial changes in concentration within 3 and 6 h. Percentage change criteria included ≥20% δ change and ROC-optimized value. Results: Based on the standard fourth-generation cTnT result of ≥0.03 μg/L, an evolving NSTEMI was diagnosed in 26 patients, and 31 patients were classified as having unstable angina. With the use of the hs-cTnT assay at the 99th-percentile cutoff, the percentage of NSTEMI cases detected increased gradually from 61.5% on presentation to 100% within 6 h, and the overall number of MI diagnoses increased by 34.6% (35 vs 26 cases). A δ change ≥20% or ≥ROC-optimized value of >117% within 3 h or ≥243% within 6 h yielded a specificity of 100% at sensitivities between 69% and 76%. The standard cTnT at the 99th percentile was less sensitive than hs-cTnT for early diagnosis of MI on presentation, and follow-up samples obtained within the initial 3 h demonstrated very low specificity of cTnT compared with hs-cTnT. Conclusions: The high-sensitivity cTnT assay increases the number of NSTEMI diagnoses and enables earlier detection of evolving NSTEMI. A doubling of the hs-cTnT concentration within 3 h in the presence of a second concentration ≥99th percentile is associated with a positive predictive value of 100% and a negative predictive value of 88%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2009.134460

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 332

Metadata

Authors
Giannitsis, E., Becker, M., Kurz, K., Hess, G., Zdunek, D., & Katus, H. A.
Venue
Clinical Chemistry
Published
2010-04-01
Volume
56
Issue
4
Pages
642-650
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2147571213
Cited by
332
References
20
FWCI
30.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Sensitivity Cardiac Troponin T for Early Prediction of Evolving Non–ST-Segment Elevation Myocardial Infarction in Patients with Suspected Acute Coronary Syndrome and Negative Troponin Results on Admission. https://app.cochat.ai/papers/10.1373/clinchem.2009.134460
The paper
Giannitsis, E., Becker, M., Kurz, K., Hess, G., Zdunek, D., & Katus, H. A. (2010). High-Sensitivity Cardiac Troponin T for Early Prediction of Evolving Non–ST-Segment Elevation Myocardial Infarction in Patients with Suspected Acute Coronary Syndrome and Negative Troponin Results on Admission. Clinical Chemistry. https://doi.org/10.1373/clinchem.2009.134460

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.