Metrologic Traceability of Total Thyroxine Measurements in Human Serum: Efforts to Establish a Network of Reference Measurement Laboratories
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: Assuring/demonstrating metrologic traceability of in vitro diagnostics necessitates the availability of measurand-specific reference measurement systems (RMSs) and the possibility for industry to work with competent reference measurement laboratories (RMLs). Here we report the results of a European project to investigate the feasibility of developing a RMS for serum total thyroxine. Methods: Four candidate RMLs (cRMLs) developed/implemented variants of a candidate reference measurement procedure (cRMP) based on isotope dilution–liquid chromatography–mass spectrometry. The sole constraint implemented was calibration with a common thyroxine primary calibrator. The RMPs were externally validated and assessed for comparability in round-robin trials using common samples, i.e., 5 lyophilized and 33 frozen native sera. At the same time, the performance of the cRMLs organized in a network was assessed. For uniform external quality assessment, common performance specifications were agreed on. Results: All cRMLs performed the cRMPs with fulfillment of the predefined specifications: total and between-laboratory CVs ≤2.0% and 2.5%, respectively, and a systematic deviation ≤0.9%, estimated with a target assigned from the mean of means obtained by the cRMLs. The mean expanded uncertainty for value assignment to the native sera was 2.1%. Conclusions: A network of cRMLs, with externally conformed competence to properly perform RMPs, has been established. Performance specifications were defined and will form the basis for admittance of new network members. A serum panel, successfully targeted during the validation process, is available for split-sample measurements with commercial routine measurement procedures. The model can now be used for other measurands for which traceability to the Système International d’Unités is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Free Hormone Hypothesis: A Physiologically Based Mathematical Model*
MENDEL, C. M. (1989) · Endocrine Reviews · doi:10.1210/edrv-10-3-232 · Cited by 961
Approved IFCC reference method for the measurement of HbA1c in human blood
Jeppsson, J.-O., Kobold, U., Barr, J., Finke, A., Hoelzel, W., Hoshino, T., Miedema, K., Mosca, A., Mauri, P., Paroni, R., et al. (2002) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2002.016 · Cited by 655
Self-citationCandidate Reference Method for Total Thyroxine in Human Serum
Tai, S. S.-C., Sniegoski, L. T., & Welch, M. J. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.4.637 · Cited by 80
Self-citation
Cited by
Van Houcke, S. K., Van Uytfanghe, K., Shimizu, E., Tani, W., Umemoto, M., & Thienpont, L. M. (2011) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2011.639 · Cited by 64
Self-citationMeasurement of serum testosterone in women; what should we do?
Kane, J., Middle, J., & Cawood, M. (2007) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/000456307779595896 · Cited by 49
Standardization activities in the field of thyroid function tests: a status report
Thienpont, L. M., Van Uytfanghe, K., & Van Houcke, S. (2010) · cclm · doi:10.1515/cclm.2010.321 · Cited by 29
Self-citationKöhrle, J., & Richards, K. H. (2020) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/a-1175-4610 · Cited by 7
Metadata
- Authors
- Thienpont, L. M., Van Uytfanghe, K., Marriot, J., Stokes, P., Siekmann, L., Kessler, A., Bunk, D., & Tai, S.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-01-01
- Volume
- 51
- Issue
- 1
- Pages
- 161-168
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2141042658
- Cited by
- 15
- References
- 3
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.