Measurement of Total Vitamin B12 and Holotranscobalamin, Singly and in Combination, in Screening for Metabolic Vitamin B12 Deficiency
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: The standard screening test for vitamin B12 deficiency, measurement of total plasma vitamin B12, has limitations of sensitivity and specificity. Plasma vitamin B12 bound to transcobalamin (holoTC) is the fraction of total vitamin B12 available for tissue uptake and therefore has been proposed as a potentially useful alternative indicator of vitamin B12 status. Methods: We compared the diagnostic accuracy of total vitamin B12, holoTC, and a combination of both measures to screen for metabolic vitamin B12 deficiency in an elderly cohort (age ≥60 years). Plasma methylmalonic acid and homocysteine were used as indicators of vitamin B12 deficiency. Results: Low total vitamin B12 (<148 pmol/L) and low holoTC (<35 pmol/L) were observed in 6.5% and 8.0%, and increased methylmalonic acid (>350 nmol/L) and homocysteine (>13 μmol/L) were observed in 12.1% and 17.0% of the study participants. In multiple regression models, holoTC explained 5%–6% more of the observed variance in methylmalonic acid and homocysteine than did total vitamin B12 (P ≤0.004). ROC curve analysis indicated that total vitamin B12 and holoTC were essentially equivalent in their ability to discriminate persons with and without vitamin B12 deficiency. Individuals with low concentrations of both total vitamin B12 and holoTC had significantly higher concentrations of methylmalonic acid and homocysteine than did individuals with total vitamin B12 and/or holoTC within the reference intervals (P <0.001). Conclusions: HoloTC and total vitamin B12 have equal diagnostic accuracy in screening for metabolic vitamin B12 deficiency. Measurement of both holoTC and total vitamin B12 provides a better screen for vitamin B12 deficiency than either assay alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Homocysteine and cognitive function in the Sacramento Area Latino Study on Aging
Miller, J. W., Green, R., Ramos, M. I., Allen, L. H., Mungas, D. M., Jagust, W. J., & Haan, M. N. (2003) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/78.3.441 · Cited by 134
Self-citation
Cited by
Green, R., Allen, L. H., Bjørke-Monsen, A.-L., Brito, A., Guéant, J.-L., Miller, J. W., Molloy, A. M., Nexo, E., Stabler, S., Toh, B.-H., et al. (2017) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2017.40 · Cited by 970
Self-citationVitamin B12 in Health and Disease
O’Leary, F., & Samman, S. (2010) · Nutrients · doi:10.3390/nu2030299 · Cited by 524
“However, when used in combination with vitamin B12 the predictive value for determining vitamin B12 deficiency is improved [10].”
BackgroundGuidelines for the diagnosis and treatment of cobalamin and folate disorders
Devalia, V., Hamilton, M. S., Molloy, A. M., & the British Committee for Standards in Haematology (2014) · British Journal of Haematology · doi:10.1111/bjh.12959 · Cited by 511
Vitamin B12 deficiency from the perspective of a practicing hematologist
Green, R. (2017) · Blood · doi:10.1182/blood-2016-10-569186 · Cited by 398
Self-citationBiomarkers of Nutrition for Development (BOND): Vitamin B-12 Review
Allen, L. H., Miller, J. W., de Groot, L., Rosenberg, I. H., Smith, A. D., Refsum, H., & Raiten, D. J. (2018) · The Journal of Nutrition · doi:10.1093/jn/nxy201 · Cited by 300
Self-citationCarmel, R. (2011) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.111.013441 · Cited by 258
Holotranscobalamin, a marker of vitamin B-12 status: analytical aspects and clinical utility
Nexo, E., & Hoffmann-Lücke, E. (2011) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.111.013458 · Cited by 250
“Although holoTC seems to identify patients with elevated MMA concentrations more effectively than does vitamin B-12, Miller et al (60) have suggested that the use of both parameters in combination is preferable.”
BackgroundPrzybelski, R. J., & Binkley, N. C. (2007) · Archives of Biochemistry and Biophysics · doi:10.1016/j.abb.2006.12.018 · Cited by 239
Vitamin B12 Intake From Animal Foods, Biomarkers, and Health Aspects
Obeid, R., Heil, S. G., Verhoeven, M. M. A., van den Heuvel, E. G. H. M., de Groot, L. C. P. G. M., & Eussen, S. J. P. M. (2019) · Frontiers in Nutrition · doi:10.3389/fnut.2019.00093 · Cited by 203
Green, R., & Datta Mitra, A. (2017) · Medical Clinics of North America · doi:10.1016/j.mcna.2016.09.013 · Cited by 196
Self-citationGreen, R. (2011) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.110.009613 · Cited by 192
“Good congruency of holoTC with plasma methylmalonate has, however, been reported, and the holoTC assay used in conjunction with the total plasma vitamin B-12 may provide enhanced predictive power to identify true vitamin B-12 deficiency (9).”
Self-citationVitamin B 12 status and rate of brain volume loss in community-dwelling elderly
Vogiatzoglou, A., Refsum, H., Johnston, C., Smith, S. M., Bradley, K. M., de Jager, C., Budge, M. M., & Smith, A. D. (2008) · Neurology · doi:10.1212/01.wnl.0000325581.26991.f2 · Cited by 192
Fedosov, S. N., Brito, A., Miller, J. W., Green, R., & Allen, L. H. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0818 · Cited by 184
Diagnosis of megaloblastic anaemias
Wickramasinghe, S. N. (2006) · Blood Reviews · doi:10.1016/j.blre.2006.02.002 · Cited by 159
Liquid chromatography–tandem mass spectrometry applications in endocrinology
Kushnir, M. M., Rockwood, A. L., & Bergquist, J. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20264 · Cited by 159
“The methods described in the review are used for routine diagnostic testing and were used in a number of epidemiological and clinical studies (Kushnir et al., 2002, 2009; Meikle et al., 2003; Choi et al., 2005; Miller et al., 2006; Singh et al., 2006; Anderson et al., 2007; Meier et al., 2008).”
MethodSelf-citationDoets, E. L., Ueland, P. M., Tell, G. S., Vollset, S. E., Nygård, O. K., van't Veer, P., de Groot, L. C. P. G. M., Nurk, E., Refsum, H., Smith, A. D., et al. (2014) · British Journal Of Nutrition · doi:10.1017/s000711451300336x · Cited by 50
Metadata
- Authors
- Miller, J. W., Garrod, M. G., Rockwood, A. L., Kushnir, M. M., Allen, L. H., Haan, M. N., & Green, R.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-02-01
- Volume
- 52
- Issue
- 2
- Pages
- 278-285
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2133337669
- Cited by
- 145
- References
- 1
- FWCI
- 5.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.