Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 343

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Analytical Validation of the Oncotype DX Genomic Diagnostic Test for Recurrence Prognosis and Therapeutic Response Prediction in Node-Negative, Estrogen Receptor–Positive Breast Cancer

Cronin, Maureen, Sangli, Chithra, Liu, Mei-Lan, Pho, Mylan, Dutta, Debjani, Nguyen, Anhthu, Jeong, Jennie, Wu, Jenny, Langone, Kim Clark, Watson, Drew·2007·Clinical Chemistry

Abstract

Background: Oncotype DX™ is a clinically validated, high-complexity, multianalyte reverse transcription–PCR genomic test that predicts the likelihood of breast cancer recurrence in early-stage, node-negative, estrogen receptor–positive breast cancer. The Recurrence Score™ (RS) provides a more accurate, reproducible measure of breast cancer aggressiveness and therapeutic responsiveness than standard measures. Individualized patient management requires strict performance criteria for clinical laboratory tests. We therefore investigated the analytical performance of the assay. Methods: Assays used a pooled RNA sample from fixed paraffin-embedded tissues to evaluate the analytical performance of a 21-gene panel with respect to amplification efficiency, precision, linearity, and dynamic range, as well as limits of detection and quantification. Performance variables were estimated from assays carried out with sample dilutions. In addition, individual patient samples were used to test the optimized assay for reproducibility and sources of imprecision. Results: Assay results defined acceptable operational performance ranges, including an estimated maximum deviation from linearity of <1 cycle threshold (CT) units over a ≥2000-fold range of RNA concentrations, with a mean quantification bias of 0.3% and CVs of 3.2%–5.7%. An analysis of study design showed that assay imprecision contributed by instrument, operator, reagent, and day-to-day baseline variation was low, with SDs of <0.5 CT. Conclusion: The analytical and operational performance specifications defined for the Oncotype DX assay allow the reporting of quantitative RS values for individual patients with an SD within 2 RS units on a 100-unit scale.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2006.076497

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 343

Metadata

Authors
Cronin, M., Sangli, C., Liu, M.-L., Pho, M., Dutta, D., Nguyen, A., Jeong, J., Wu, J., Langone, K. C., & Watson, D.
Venue
Clinical Chemistry
Published
2007-06-01
Volume
53
Issue
6
Pages
1084-1091
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2129859749
Cited by
343
References
30
FWCI
5.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).