CoChat

Diagnostic Accuracy of ELISA and xMAP Technology for Analysis of Amyloid β42 and Tau Proteins

Reijn, Thierry SM, Rikkert, Marcel Olde, van Geel, Wieneke JA, de Jong, Danielle, Verbeek, Marcel M · 2007 · Clinical Chemistry
Cited by 66

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Background: Cerebrospinal fluid (CSF) concentrations of amyloid β42 (Aβ42) peptides and tau proteins may serve as biomarkers for Alzheimer disease (AD). Recently, the xMAP technology has been introduced as an alternative to ELISA for measurement of these markers. Methods: We used xMAP assays and ELISA to analyze CSF concentrations of Aβ42, total tau (t-tau), and tau phosphorylated at threonine 181 (p-tau181) in samples from 69 patients with Alzheimer disease, 26 patients with vascular dementia, and 55 controls without neurological disorders. Results: High CV values (>28%) for the ratio of xMAP:ELISA were observed for each biomarker, indicating that a constant correction factor cannot be applied to recalculate xMAP results into ELISA results. When a combination of CSF markers was used, the sensitivity, specificity, and area under the ROC curves for xMAP assays and ELISAs were not significantly different in differentiating AD patients from vascular dementia patients and controls. Conclusions: A constant conversion factor cannot be used successfully to recalculate results obtained with xMAP assays to those from the ELISAs. With the use of analysis of a combination of Aβ42, t-tau, and p-tau in CSF, however, differentiation of clinical groups is equivalent when either xMAP technology or conventional ELISA is used.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2006.081679

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 66

Metadata

Authors
Reijn, T. S., Rikkert, M. O., van Geel, W. J., de Jong, D., & Verbeek, M. M.
Venue
Clinical Chemistry
Published
2007-05-01
Volume
53
Issue
5
Pages
859-865
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2158067082
Cited by
66
References
12
FWCI
2.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic Accuracy of ELISA and xMAP Technology for Analysis of Amyloid β42 and Tau Proteins. https://app.cochat.ai/papers/10.1373/clinchem.2006.081679
The paper
Reijn, T. S., Rikkert, M. O., van Geel, W. J., de Jong, D., & Verbeek, M. M. (2007). Diagnostic Accuracy of ELISA and xMAP Technology for Analysis of Amyloid β42 and Tau Proteins. Clinical Chemistry. https://doi.org/10.1373/clinchem.2006.081679

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.