Ultrasensitive Flow-based Immunoassays Using Single-Molecule Counting
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Background: Immunoassay (IA) technology has expanded the clinical utility of protein biomarkers, but demands for increased sensitivity, dynamic reporting ranges, and small sample volumes have limited the potential clinical usefulness of many biomarkers. We assessed the performance, including limits of detection (LODs) and the dynamic reporting range, of an IA-based technology, Erenna Immunoassay System, for a series of biomarkers, including cardiac troponin I (cTnI). Methods: Erenna IAs were used with 10 different and clinically important biomarkers to ascertain the LOD with various sample sizes (10 μL to 200 μL). Results: The Erenna Immunoassay System generated LODs of 10–100 pg/L using 100 μL of sample. For cTnI, the LOD was 0.2 ng/L and a 10% CV was seen between 0.78 and 1.6 ng/L. Conclusions: The Erenna IA-based technology reproducibly measures protein biomarkers with detection limits of 10–100 pg/L, with a dynamic range of >4.5 logs in sample volumes of 50–150 μL.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wu, A. H. B., Fukushima, N. H., Puskas, R., Todd, J., & Goix, P. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2006.073163 · Cited by 138
Self-citationMeasurement of Cytokines in Clinical Samples Using Immunoassays: Problems and Pitfalls
Banks, R. E. (2000) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408360091174187 · Cited by 78
Assays for cytokines using aptamers
Guthrie, J. W., Hamula, C. L. A., ZHANG, H., & Le, X. C. (2006) · Methods · doi:10.1016/j.ymeth.2006.01.001 · Cited by 62
Viral RNA and p24 Antigen as Markers of HIV Disease and Antiretroviral Treatment Success
Schüpbach, J. (2003) · International Archives of Allergy and Immunology · doi:10.1159/000074552 · Cited by 55
Blood cardiac troponin in toxic myocardial injury: archetype of a translational safety biomarker
O'Brien, P. J. (2006) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.6.5.685 · Cited by 55
Cited by
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119
How to use high-sensitivity cardiac troponins in acute cardiac care
Thygesen, K., Mair, J., Giannitsis, E., Mueller, C., Lindahl, B., Blankenberg, S., Huber, K., Plebani, M., Biasucci, L. M., Tubaro, M., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs154 · Cited by 784
Prognostic Utility of Novel Biomarkers of Cardiovascular Stress: The Framingham Heart Study
Wang, T. J., Wollert, K. C., Larson, M. G., Coglianese, E., McCabe, E. L., Cheng, S., Ho, J. E., Fradley, M. G., Ghorbani, A., Xanthakis, V., et al. (2012) · Circulation · doi:10.1161/circulationaha.112.129437 · Cited by 482
“Quantification of hsTnI was performed with an ultra-sensitive immunoassay for cardiac troponin I that utilizes a novel, single-molecule counting technology (Erenna hsTnI, Singulex).(30) The limit of detection is 0.”
MethodWilson, D. H., Rissin, D. M., Kan, C. W., Fournier, D. R., Piech, T., Campbell, T. G., Meyer, R. E., Fishburn, M. W., Cabrera, C., Patel, P. P., et al. (2016) · SLAS Technology · doi:10.1177/2211068215589580 · Cited by 470
Guo, K., Wustoni, S., Koklu, A., Díaz-Galicia, E., Moser, M., Hama, A., Alqahtani, A. A., Ahmad, A. N., Alhamlan, F. S., Shuaib, M., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00734-9 · Cited by 410
Single-Molecule Plasmon Sensing: Current Status and Future Prospects
Taylor, A. B., & Zijlstra, P. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00382 · Cited by 366
Lipshultz, S. E., Miller, T. L., Scully, R. E., Lipsitz, S. R., Rifai, N., Silverman, L. B., Colan, S. D., Neuberg, D. S., Dahlberg, S. E., Henkel, J. M., et al. (2012) · Journal of Clinical Oncology · doi:10.1200/jco.2010.30.3404 · Cited by 323
Fluid biomarkers for mild traumatic brain injury and related conditions
Zetterberg, H., & Blennow, K. (2016) · Nature Reviews Neurology · doi:10.1038/nrneurol.2016.127 · Cited by 320
Lewczuk, P., Riederer, P., O’Bryant, S. E., Verbeek, M. M., Dubois, B., Visser, P. J., Jellinger, K. A., Engelborghs, S., Ramirez, A., Parnetti, L., et al. (2018) · The World Journal of Biological Psychiatry · doi:10.1080/15622975.2017.1375556 · Cited by 307
Amyloid‐beta oligomerization in Alzheimer dementia versus high‐pathology controls
Esparza, T. J., Zhao, H., Cirrito, J. R., Cairns, N. J., Bateman, R. J., Holtzman, D. M., & Brody, D. L. (2013) · Annals of Neurology · doi:10.1002/ana.23748 · Cited by 306
Mingels, A., Jacobs, L., Michielsen, E., Swaanenburg, J., Wodzig, W., & van Dieijen-Visser, M. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.106427 · Cited by 295
Highly Sensitive and Multiplexed Protein Measurements
Cohen, L., & Walt, D. R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00257 · Cited by 294
Sabatine, M. S., Morrow, D. A., de Lemos, J. A., Jarolim, P., & Braunwald, E. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn504 · Cited by 277
O’Brien, P. J. (2008) · Toxicology · doi:10.1016/j.tox.2007.12.006 · Cited by 270
Wild, E. J., Boggio, R., Langbehn, D., Robertson, N., Haider, S., Miller, J. R. C., Zetterberg, H., Leavitt, B. R., Kuhn, R., Tabrizi, S. J., et al. (2015) · Journal of Clinical Investigation · doi:10.1172/jci80743 · Cited by 268
Wu, A. H. B., Lu, Q. A., Todd, J., Moecks, J., & Wians, F. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.107391 · Cited by 267
Self-citationvan Reenen, A., de Jong, A. M., den Toonder, J. M. J., & Prins, M. W. J. (2014) · Lab Chip · doi:10.1039/c3lc51454d · Cited by 262
Rissin, D. M., Fournier, D. R., Piech, T., Kan, C. W., Campbell, T. G., Song, L., Chang, L., Rivnak, A. J., Patel, P. P., Provuncher, G. K., et al. (2011) · Analytical Chemistry · doi:10.1021/ac103161b · Cited by 255
Cardiac biomarkers and the case for point-of-care testing
McDonnell, B., Hearty, S., Leonard, P., & O'Kennedy, R. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.01.019 · Cited by 254
Optical Methods for Single Molecule Detection and Analysis
Walt, D. R. (2013) · Analytical Chemistry · doi:10.1021/ac3027178 · Cited by 226
Smith, J. G., & Gerszten, R. E. (2017) · Circulation · doi:10.1161/circulationaha.116.025446 · Cited by 206
Recent Development of Cardiac Troponin I Detection
Han, X., Li, S., Peng, Z., Othman, A. M., & Leblanc, R. (2016) · ACS Sensors · doi:10.1021/acssensors.5b00318 · Cited by 175
Ultrasensitive protein detection: a case for microfluidic magnetic bead-based assays
Tekin, H. C., & Gijs, M. A. M. (2013) · Lab on a Chip · doi:10.1039/c3lc50477h · Cited by 160
Yang, T., Dang, Y., Ostaszewski, B., Mengel, D., Steffen, V., Rabe, C., Bittner, T., Walsh, D. M., & Selkoe, D. J. (2019) · Annals of Neurology · doi:10.1002/ana.25513 · Cited by 91
“Erenna-Based Aβ Oligomer Immunoassay The Erenna Immunoassay System (Millipore) is based on single-molecule counting technology and typically allows a 20- to 100-fold increase in sensitivity over traditional enzyme-linked immunosorbent assays.(20) To capture oligomers, a suspension of 1C22-MP was diluted to 100μg/ml in…”
Method
Metadata
- Authors
- Todd, J., Freese, B., Lu, A., Held, D., Morey, J., Livingston, R., & Goix, P.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-11-01
- Volume
- 53
- Issue
- 11
- Pages
- 1990-1995
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1991461818
- Cited by
- 289
- References
- 5
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.