CoChat

Interlaboratory Agreement of Insulin-like Growth Factor 1 Concentrations Measured by Mass Spectrometry

Cox, Holly D, Lopes, Filipe, Woldemariam, Getachew A, Becker, Jessica O, Parkin, Mark C, Thomas, Andreas, Butch, Anthony W, Cowan, David A, Thevis, Mario, Bowers, Larry D, Hoofnagle, Andrew N · 2014 · Clinical Chemistry
Cited by 107

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Insulin-like growth factor 1 (IGF-1)7 is a key mediator of growth hormone (GH) action and a well-characterized biomarker of GH abuse. Current immunoassays for IGF-1 suffer from poor concordance between platforms, which makes comparison of results between laboratories difficult. Although previous work has demonstrated good interlaboratory imprecision of LC-MS/MS methods when plasma is supplemented with purified proteins, the interlaboratory imprecision of an endogenous protein in the nanogram-per-milliliter concentration range has not been reported. METHODS: We deployed an LC-MS/MS method to quantify serum IGF-1 in 5 laboratories using 5 different instruments and analyzed 130 healthy human samples and 22 samples from patients with acromegaly. We determined measurement imprecision (CV) for differences due to instrumentation, calibration curve construction, method of calibration, and reference material. RESULTS: Instrument-dependent variation, exclusive of digestion, across 5 different instrument platforms was determined to be 5.6%. Interlaboratory variation was strongly dependent on calibration. Calibration materials from a single laboratory resulted in less variation than materials made in individual laboratories (CV 5.2% vs 12.8%, respectively). The mean imprecision for 152 samples between the 5 laboratories was 16.0% when a calibration curve was made in each laboratory and 11.1% when a single-point calibration approach was used. CONCLUSIONS: The interlaboratory imprecision of serum IGF-1 concentrations is acceptable for use of the assay in antidoping laboratories and in standardizing results across clinical laboratories. The primary source of variability is not derived from the sample preparation but from the method of calibration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2013.208538

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 107

Metadata

Authors
Cox, H. D., Lopes, F., Woldemariam, G. A., Becker, J. O., Parkin, M. C., Thomas, A., Butch, A. W., Cowan, D. A., Thevis, M., Bowers, L. D., & Hoofnagle, A. N.
Venue
Clinical Chemistry
Published
2014-03-01
Volume
60
Issue
3
Pages
541-548
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2074392515
Cited by
107
References
6
FWCI
7.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Interlaboratory Agreement of Insulin-like Growth Factor 1 Concentrations Measured by Mass Spectrometry. https://app.cochat.ai/papers/10.1373/clinchem.2013.208538
The paper
Cox, H. D., Lopes, F., Woldemariam, G. A., Becker, J. O., Parkin, M. C., Thomas, A., Butch, A. W., Cowan, D. A., Thevis, M., Bowers, L. D., & Hoofnagle, A. N. (2014). Interlaboratory Agreement of Insulin-like Growth Factor 1 Concentrations Measured by Mass Spectrometry. Clinical Chemistry. https://doi.org/10.1373/clinchem.2013.208538

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.