Considerations for Digital PCR as an Accurate Molecular Diagnostic Tool
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Digital PCR (dPCR) is an increasingly popular manifestation of PCR that offers a number of unique advantages when applied to preclinical research, particularly when used to detect rare mutations and in the precise quantification of nucleic acids. As is common with many new research methods, the application of dPCR to potential clinical scenarios is also being increasingly described. CONTENT: This review addresses some of the factors that need to be considered in the application of dPCR. Compared to real-time quantitative PCR (qPCR), dPCR clearly has the potential to offer more sensitive and considerably more reproducible clinical methods that could lend themselves to diagnostic, prognostic, and predictive tests. But for this to be realized the technology will need to be further developed to reduce cost and simplify application. Concomitantly the preclinical research will need be reported with a comprehensive understanding of the associated errors. dPCR benefits from a far more predictable variance than qPCR but is as susceptible to upstream errors associated with factors like sampling and extraction. dPCR can also suffer systematic bias, particularly leading to underestimation, and internal positive controls are likely to be as important for dPCR as they are for qPCR, especially when reporting the absence of a sequence. SUMMARY: In this review we highlight some of the considerations that may be needed when applying dPCR and discuss sources of error. The factors discussed here aim to assist in the translation of dPCR to diagnostic, predictive, or prognostic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770
Simultaneous Amplification and Detection of Specific DNA Sequences
Higuchi, R., Dollinger, G., Walsh, P. S., & Griffith, R. (1992) · Bio/Technology · doi:10.1038/nbt0492-413 · Cited by 1,130
Evaluation of a Droplet Digital Polymerase Chain Reaction Format for DNA Copy Number Quantification
Pinheiro, L. B., Coleman, V. A., Hindson, C. M., Herrmann, J., Hindson, B. J., Bhat, S., & Emslie, K. R. (2012) · Analytical Chemistry · doi:10.1021/ac202578x · Cited by 1,055
Huggett, J. F., Foy, C. A., Benes, V., Emslie, K., Garson, J. A., Haynes, R., Hellemans, J., Kubista, M., Mueller, R. D., Nolan, T., et al. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.206375 · Cited by 859
Self-citationERBB2 amplification in breast cancer analyzed by fluorescence in situ hybridization
Kallioniemi, O. P., Kallioniemi, A., Kurisu, W., Thor, A., Chen, L. C., Smith, H. S., Waldman, F. M., Pinkel, D., & Gray, J. W. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5321 · Cited by 555
Highly Precise Measurement of HIV DNA by Droplet Digital PCR
Strain, M. C., Lada, S. M., Luong, T., Rought, S. E., Gianella, S., Terry, V. H., Spina, C. A., Woelk, C. H., & Richman, D. D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055943 · Cited by 504
Taly, V., Pekin, D., Benhaim, L., Kotsopoulos, S. K., Le Corre, D., Li, X., Atochin, I., Link, D. R., Griffiths, A. D., Pallier, K., et al. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.206359 · Cited by 492
Whale, A. S., Huggett, J. F., Cowen, S., Speirs, V., Shaw, J., Ellison, S., Foy, C. A., & Scott, D. J. (2012) · Nucleic Acids Research · doi:10.1093/nar/gks203 · Cited by 453
Self-citationDigital PCR for the molecular detection of fetal chromosomal aneuploidy
Lo, Y. M. D., Lun, F. M. F., Chan, K. C. A., Tsui, N. B. Y., Chong, K. C., Lau, T. K., Leung, T. Y., Zee, B. C. Y., Cantor, C. R., & Chiu, R. W. K. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0705765104 · Cited by 434
Standardized definitions of molecular response in chronic myeloid leukemia
Cross, N. C. P., White, H. E., Müller, M. C., Saglio, G., & Hochhaus, A. (2012) · Leukemia · doi:10.1038/leu.2012.104 · Cited by 378
Cited by
ESR1 mutations—a mechanism for acquired endocrine resistance in breast cancer
Jeselsohn, R., Buchwalter, G., De Angelis, C., Brown, M., & Schiff, R. (2015) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2015.117 · Cited by 704
Quan, P.-L., Sauzade, M., & Brouzes, E. (2018) · Sensors · doi:10.3390/s18041271 · Cited by 664
The dMIQE Group, Whale, A. S., De Spiegelaere, W., Trypsteen, W., Nour, A. A., Bae, Y.-K., Benes, V., Burke, D., Cleveland, M., Corbisier, P., et al. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvaa125 · Cited by 516
Self-citationRecent Advances in Droplet Microfluidics
Ding, Y., Howes, P. D., & deMello, A. J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05047 · Cited by 357
Liquid Biopsy: General Concepts
Poulet, G., Massias, J., & Taly, V. (2019) · Acta Cytologica · doi:10.1159/000499337 · Cited by 332
Medema, G., Been, F., Heijnen, L., & Petterson, S. (2020) · Current Opinion in Environmental Science & Health · doi:10.1016/j.coesh.2020.09.006 · Cited by 307
Digital Assays Part I: Partitioning Statistics and Digital PCR
Basu, A. S. (2017) · SLAS Technology · doi:10.1177/2472630317705680 · Cited by 300
Advances in digital polymerase chain reaction (dPCR) and its emerging biomedical applications
Cao, L., Cui, X., Hu, J., Li, Z., Choi, J. R., Yang, Q., Lin, M., Ying Hui, L., & Xu, F. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.082 · Cited by 291
Applications of Digital PCR for Clinical Microbiology
Kuypers, J., & Jerome, K. R. (2017) · Journal of Clinical Microbiology · doi:10.1128/jcm.00211-17 · Cited by 280
Li, T., Shao, Y., Fu, L., Xie, Y., Zhu, L., Sun, W., Yu, R., Xiao, B., & Guo, J. (2018) · Journal of Molecular Medicine · doi:10.1007/s00109-017-1600-y · Cited by 266
Virus Detection: From State‐of‐the‐Art Laboratories to Smartphone‐Based Point‐of‐Care Testing
Xiao, M., Tian, F., Liu, X., Zhou, Q., Pan, J., Luo, Z., Yang, M., & Yi, C. (2022) · Advanced Science · doi:10.1002/advs.202105904 · Cited by 218
Current and Emerging Applications of Droplet Digital PCR in Oncology
Olmedillas-López, S., García-Arranz, M., & García-Olmo, D. (2017) · Molecular Diagnosis & Therapy · doi:10.1007/s40291-017-0278-8 · Cited by 201
“At the time these methodologies were described, they were hindered by technical and economic limitations that were later circumvented by the development of improved nanofluidic devices and emulsion-based formulations for sub-partitioning [14].”
MethodDigital PCR—An Emerging Technology with Broad Applications in Microbiology
Salipante, S. J., & Jerome, K. R. (2020) · Clinical Chemistry · doi:10.1373/clinchem.2019.304048 · Cited by 159
Detection and Identification of Genome Editing in Plants: Challenges and Opportunities
Grohmann, L., Keilwagen, J., Duensing, N., Dagand, E., Hartung, F., Wilhelm, R., Bendiek, J., & Sprink, T. (2019) · Frontiers in Plant Science · doi:10.3389/fpls.2019.00236 · Cited by 135
Digital PCR: A Sensitive and Precise Method for KIT D816V Quantification in Mastocytosis
Greiner, G., Gurbisz, M., Ratzinger, F., Witzeneder, N., Simonitsch-Klupp, I., Mitterbauer-Hohendanner, G., Mayerhofer, M., Müllauer, L., Sperr, W. R., Valent, P., et al. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2017.277897 · Cited by 83
Li, Z., Pan, L., Lyu, L., Li, J., Jia, H., Du, B., Sun, Q., & Zhang, Z. (2020) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2019.07.015 · Cited by 32
Evaluating the use of PCR for diagnosing invasive aspergillosis
Buchheidt, D., Reinwald, M., Hofmann, W.-K., Boch, T., & Spiess, B. (2017) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2017.1325735 · Cited by 17
Crupi, F., Caroprese, J., & Mannelli, F. (2025) · Frontiers in Allergy · doi:10.3389/falgy.2025.1592001 · Cited by 2
Metadata
- Authors
- Huggett, J. F., Cowen, S., & Foy, C. A.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-01-01
- Volume
- 61
- Issue
- 1
- Pages
- 79-88
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2078148381
- Cited by
- 444
- References
- 46
- FWCI
- 15.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.