CoChat

Routine use of the Ion Torrent AmpliSeq™ Cancer Hotspot Panel for identification of clinically actionable somatic mutations

Tsongalis, Gregory J., Peterson, Jason D., de Abreu, Francine B., Tunkey, Christopher D., Gallagher, Torrey L., Strausbaugh, Linda D., Wells, Wendy A., Amos, Christopher I. · 2014 · Clinical Chemistry and Laboratory Medicine
Cited by 140

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Somatic mutation analysis is standard of practice for solid tumors in order to identify therapeutic sensitizing and resistance mutations. Our laboratory routinely performed standalone PCR-based methods for mutations in several genes. Rapid discovery and introduction of new therapeutics has demanded additional genomic information for adequate management of the cancer patient. We evaluated a next generation sequencing assay, the Ion Torrent AmpliSeq Cancer Hotspot Panelv2 (CHPv2), capable of identifying multiple somatic mutations in 50 genes in a single assay. METHODS: Accuracy, precision, limit of detection, and specificity were evaluated using DNA from well-characterized cell lines, genetically engineered cell lines fixed and embedded in paraffin, and previously tested mutation positive or negative, formalin-fixed, paraffin-embedded (FFPE) tissues. Normal kidney, tonsil and colon FFPE tissues were used as controls. RESULTS: Accuracy studies showed 100% concordance in each patient sample between previous PCR results and the corresponding variants identified using the Ion Torrent panel. Precision studies gave consistent results when libraries were prepared from the same original DNA and were run on multiple 316 chips. The limit of detection was determined to be 5% for single nucleotide variants (SNVs) and 20% for insertions and deletions (indels). Specificity studies using normal FFPE tissue previously tested by PCR methods were also 100%. CONCLUSIONS: We have evaluated the performance of the AmpliSeq Cancer Panel Hotspotv2 and show that it is suitable for clinical testing. This next generation sequencing panel has allowed the laboratory to consolidate a broader range of molecular oncology testing to a single platform and single assay.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm-2013-0883

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 140

Metadata

Authors
Tsongalis, G. J., Peterson, J. D., de Abreu, F. B., Tunkey, C. D., Gallagher, T. L., Strausbaugh, L. D., Wells, W. A., & Amos, C. I.
Venue
Clinical Chemistry and Laboratory Medicine
Published
2014-01-01
Volume
52
Issue
5
Pages
707-14
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W2332094695
Cited by
140
References
6
FWCI
6.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.