Preanalytical quality control program – an overview of results (2001–2005 summary)
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Preanalytical variables, such as sample collection, handling, transport, and storage, may affect patient results. The number of errors in the preanalytical phase may decrease by following standardized procedures. METHODS: A retrospective analysis (2001-2005) of results obtained through the Spanish Society of Clinical Chemistry and Molecular Pathology Quality Assessment Program for the Preanalytical Phase has been carried out to summarize data regarding the main factors affecting the preanalytical phase quality. In such a program, participants are asked to register rejections and causes for rejection of routine or stat samples usually and locally collected at their laboratories. RESULTS: Results discussed refer to 105 laboratories. Of the 4,715,132 tubes expected to be received during the data collection period among participating laboratories and according to determinations included by clinicians in the request form, 32,977 (0.699%) offered a cause for rejection. Whole blood-EDTA samples and serum samples accounted for 75.6% of all samples collected among laboratories, although they only corresponded to 55.8% of all registered rejections. In total, 81% of rejections arose as a result of the following reasons: "specimen not received" (37.5%), "hemolysis" (29.3%), and "clotted sample" (14.4%). Moreover, plasma-citrate-erythrocyte sedimentation rate exhibited the highest percentage of rejection (1.473%), whereas the lowest rate corresponded to whole blood-EDTA (0.381%). CONCLUSIONS: Overall percentage of rejection is similar to previously published data. As some of the included variables have turned out to be irrelevant, the program has been simplified from the year 2006 onwards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonini, P., Plebani, M., Ceriotti, F., & Rubboli, F. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.691 · Cited by 850
Cited by
Preanalytical quality improvement: from dream to reality
Lippi, G., Chance, J. J., Church, S., Dazzi, P., Fontana, R., Giavarina, D., Grankvist, K., Huisman, W., Kouri, T., Palicka, V., et al. (2011) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2011.600 · Cited by 388
Simundic, A.-M., Cornes, M., Grankvist, K., Lippi, G., Nybo, M., Kovalevskaya, S., Sprongl, L., Sumarac, Z., & Church, S. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0283 · Cited by 84
Nikolac, N., Lenicek Krleza, J., & Simundic, A.-M. (2017) · Biochemia Medica · doi:10.11613/bm.2017.017 · Cited by 18
Bostic, G., Thompson, R., Atanasoski, S., Canlas, C., Ye, H., Kolins, M., & Smith, M. D. (2015) · Laboratory Medicine · doi:10.1309/lma4wyn3xfukelbd · Cited by 14
Metadata
- Authors
- Alsina, M. J., Álvarez, V., Barba, N., Bullich, S., Cortés, M., Escoda, I., & Martínez-Brú, C.
- Venue
- Clinical Chemistry and Laboratory Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 2008-01-01
- Volume
- 46
- Issue
- 6
- Pages
- 849-54
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2004621922
- Cited by
- 63
- References
- 1
- FWCI
- 3.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.