The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories
Abstract
Prevention of medical errors is a major goal of healthcare, though healthcare workers themselves have not yet fully accepted or implemented reliable models of system error, and neither has the public. While there is widespread perception that most medical errors arise from an inappropriate or delayed clinical management, the issue of laboratory errors is receiving a great deal of attention due to their impact on the quality and efficiency of laboratory performances and patient safety. Haemolytic specimens are a frequent occurrence in clinical laboratories, and prevalence can be as high as 3.3% of all of the routine samples, accounting for up to 40%-70% of all unsuitable specimens identified, nearly five times higher than other causes, such as insufficient, incorrect and clotted samples. This article focuses on this challenging issue, providing an overview on prevalence and leading causes of in vivo and in vitro haemolysis, and tentative guidelines on identification and management of haemolytic samples in clinical laboratories. This strategy includes continuous education of healthcare personnel, systematic detection/quantification of haemolysis in any sample, immediate clinicians warning on the probability of in vivo haemolysis, registration of non-conformity, completing of tests unaffected by haemolysis and request of a second specimen for those potentially affected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rother, R. P., Bell, L., Hillmen, P., & Gladwin, M. T. (2005) · JAMA · doi:10.1001/jama.293.13.1653 · Cited by 1,557
Current databases on biological variation: pros, cons and progress
C. Ricós, V. A. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185229 · Cited by 987
Bonini, P., Plebani, M., Ceriotti, F., & Rubboli, F. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.691 · Cited by 850
Self-citationErrors in clinical laboratories or errors in laboratory medicine?
Plebani, M. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.123 · Cited by 734
Self-citationErrors in a Stat Laboratory: Types and Frequencies 10 Years Later
Carraro, P., & Plebani, M. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.088344 · Cited by 670
Self-citationInfluence of hemolysis on routine clinical chemistry testing
Lippi, G., Luca Salvagno, G., Montagnana, M., Brocco, G., & Cesare Guidi, G. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.054 · Cited by 344
Self-citationSelby, C. (1999) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329903600603 · Cited by 316
Sandars, J., & Esmail, A. (2003) · Family Practice · doi:10.1093/fampra/cmg301 · Cited by 298
Interference with clinical laboratory analyses
Kroll, M. H., & Elin, R. J. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.11.1996 · Cited by 269
Effect of anticoagulants and storage temperatures on stability of plasma and serum hormones
Evans, M. J., Livesey, J. H., Ellis, M. J., & Yandle, T. G. (2001) · Clinical Biochemistry · doi:10.1016/s0009-9120(01)00196-5 · Cited by 223
Hemolyzed Specimens: A Reason for Rejection or a Clinical Challenge?
Carraro, P., Servidio, G., & Plebani, M. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.2.306 · Cited by 218
Self-citationErrors in laboratory medicine and patient safety: the road ahead
Plebani, M. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.170 · Cited by 184
Self-citationRisk management in the preanalytical phase of laboratory testing
Lippi, G., & Guidi, G. C. (2007) · Clinical Chemical Laboratory Medicine · doi:10.1515/cclm.2007.167 · Cited by 176
Self-citationPhlebotomy issues and quality improvement in results of laboratory testing.
Lippi, G., Salvagno, G. L., Montagnana, M., Franchini, M., & Guidi, G. C. (2006) · PubMed · Cited by 159
Self-citationHaemolysis as an interference factor in clinical chemistry.
Sonntag, O. (1986) · PubMed · Cited by 137
The effect of blood drawing techniques and equipment on the hemolysis of ED laboratory blood samples
Grant, M. S. (2003) · Journal of Emergency Nursing · doi:10.1067/men.2003.66 · Cited by 134
Shifting emphasis from pharmacogenomics to theragnostics
Özdemir, V., Williams–Jones, B., Glatt, S. J., Tsuang, M. T., Lohr, J. B., & Reist, C. (2006) · Nature Biotechnology · doi:10.1038/nbt0806-942 · Cited by 130
Jones, B. A., Calam, R. R., & Howanitz, P. J. (1997) · PubMed · Cited by 128
Recommendations for detection and management of unsuitable samples in clinical laboratories
Lippi, G., Banfi, G., Buttarello, M., Ceriotti, F., Daves, M., Dolci, A., Caputo, M., Giavarina, D., Montagnana, M., Miconi, V., et al. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.174 · Cited by 120
Self-citationDugan, L., Leech, L., Speroni, K., & Corriher, J. (2005) · Journal of Emergency Nursing · doi:10.1016/j.jen.2005.05.004 · Cited by 103
Hemolysis in Serum Samples Drawn by Emergency Department Personnel versus Laboratory Phlebotomists
Burns, E., & Yoshikawa, N. (2002) · Laboratory Medicine · doi:10.1309/pgm4-4f8l-2p1m-lkpb · Cited by 100
Interference of Blood Cell Lysis on Routine Coagulation Testing
Lippi, G., Montagnana, M., Salvagno, G. L., & Guidi, G. C. (2006) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2006-130-181-iobclo · Cited by 85
Self-citationUnusual results from immunoassays and the role of the clinical endocrinologist
Jones, A. M., & Honour, J. W. (2006) · Clinical Endocrinology · doi:10.1111/j.1365-2265.2006.02439.x · Cited by 80
Laboratory Medicine: Challenges and Opportunities
Bossuyt, X., Verweire, K., & Blanckaert, N. J. C. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.093989 · Cited by 79
Self-citationJay, D. W., & Provasek, D. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.9.1804 · Cited by 73
The Effect of Specimen Hemolysis on Coagulation Test Results
Laga, A. C., Cheves, T. A., & Sweeney, J. D. (2006) · American Journal of Clinical Pathology · doi:10.1309/03fk-3378-ytra-1frf · Cited by 71
Pneumatic tube system induced haemolysis: assessing sample type susceptibility to haemolysis
Sodi, R., Darn, S. M., & Stott, A. (2004) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/000456304323019631 · Cited by 67
Grafmeyer, D., Bondon, M., Manchon, M., & Levillain, P. (1995) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1995.33.1.31 · Cited by 59
Correction and reporting of potassium results in haemolysed samples
Dimeski, G., Clague, A. E., & Hickman, P. E. (2005) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/0004563053492739 · Cited by 58
The impact of hemolysis on Ortho-Clinical Diagnostic's ECi and Roche's elecsys immunoassay systems
Snyder, J. A., Rogers, M. W., King, M. S., Phillips, J. C., Chapman, J. F., & Hammett‐Stabler, C. A. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.05.017 · Cited by 49
Vermeer, H. J., Steen, G., Naus, A. J. M., Goevaerts, B., Agricola, P. T., & Schoenmakers, C. H. H. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.004 · Cited by 47
Collecting factors related to the haemolysis of blood specimens.
Fang, L., Fang, S.-H., Chung, Y., & Chien, S.-T. (2008) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2006.02057.x · Cited by 41
Correction of factitious hyperkalemia in hemolyzed specimens
Owens, H., Siparsky, G. L., Bajaj, L., & Hampers, L. C. (2005) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2005.05.011 · Cited by 40
Mechanism of interference by haemolysis in the cardiac troponin T immunoassay
Sodi, R., Darn, S. M., Davison, A. S., Stott, A., & Shenkin, A. (2005) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/000456306775141687 · Cited by 39
Coagulation and plasma fibronectin parameters in HELLP syndrome
Paternoster, D. M., Stella, A., Simioni, P., Mussap, M., & Plebani, M. (1995) · International Journal of Gynecology & Obstetrics · doi:10.1016/0020-7292(95)02463-m · Cited by 39
Self-citationHaemolysis as an influence and interference factor in clinical chemistry.
Guder, W. (1986) · PubMed · Cited by 35
Variability in Potassium/Hemoglobin Ratios for Hemolysis Correction
Hawkins, R. C. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.796 · Cited by 32
Process and risk analysis to reduce errors in clinical laboratories
Signori, C., Ceriotti, F., Sanna, A., Plebani, M., Messeri, G., Ottomano, C., Serio, F. D., & Bonini, P. A. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.172 · Cited by 26
Self-citationEvaluation of Interferences in Rate and Fixed-Time Nephelometric Assays of Specific Serum Proteins
Bossuyt, X., & Blanckaert, N. J. C. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.1.62 · Cited by 21
Self-citation
Cited by
The detection and prevention of errors in laboratory medicine
Plebani, M. (2010) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2009.009222 · Cited by 479
Self-citationOptimization of the Hemolysis Assay for the Assessment of Cytotoxicity
Sæbø, I., Bjørås, M., Franzyk, H., Helgesen, E., & Booth, J. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24032914 · Cited by 461
Preanalytical quality improvement: from dream to reality
Lippi, G., Chance, J. J., Church, S., Dazzi, P., Fontana, R., Giavarina, D., Grankvist, K., Huisman, W., Kouri, T., Palicka, V., et al. (2011) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2011.600 · Cited by 388
Self-citationLipemia: causes, interference mechanisms, detection and management
Nikolac, N. (2014) · Biochemia Medica · doi:10.11613/bm.2014.008 · Cited by 290
O'Bryant, S. E., Gupta, V., Henriksen, K., Edwards, M., Jeromin, A., Lista, S., Bazenet, C., Soares, H., Lovestone, S., Hampel, H., et al. (2015) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2014.08.099 · Cited by 290
Metadata
- Authors
- Lippi, G., Blanckaert, N., Bonini, P., Green, S., Kitchen, S., Palicka, V., Vassault, A. J., & Plebani, M.
- Venue
- Clinical Chemistry and Laboratory Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 2008-01-01
- Volume
- 46
- Issue
- 6
- Pages
- 764-72
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2166607406
- Cited by
- 466
- References
- 39
- FWCI
- 9.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.