CoChat

Validation of a Video Analysis Software Package for Quantifying Movement Velocity in Resistance Exercises

Open access
Sañudo, Borja, Rueda, David, Pozo-Cruz, Borja del, de Hoyo, Moisés, Carrasco, Luis · 2016 · Journal of Strength and Conditioning Research
Cited by 47

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Sañudo, B, Rueda, D, del Pozo-Cruz, B, de Hoyo, M, and Carrasco, L. Validation of a video analysis software package for quantifying movement velocity in resistance exercises. J Strength Cond Res 30(10): 2934–2941, 2016—The aim of this study was to establish the validity of a video analysis software package in measuring mean propulsive velocity (MPV) and the maximal velocity during bench press. Twenty-one healthy males (21 ± 1 year) with weight training experience were recruited, and the MPV and the maximal velocity of the concentric phase (Vmax) were compared with a linear position transducer system during a standard bench press exercise. Participants performed a 1 repetition maximum test using the supine bench press exercise. The testing procedures involved the simultaneous assessment of bench press propulsive velocity using 2 kinematic (linear position transducer and semi-automated tracking software) systems. High Pearson's correlation coefficients for MPV and Vmax between both devices ( r = 0.473 to 0.993) were observed. The intraclass correlation coefficients for barbell velocity data and the kinematic data obtained from video analysis were high (>0.79). In addition, the low coefficients of variation indicate that measurements had low variability. Finally, Bland-Altman plots with the limits of agreement of the MPV and Vmax with different loads showed a negative trend, which indicated that the video analysis had higher values than the linear transducer. In conclusion, this study has demonstrated that the software used for the video analysis was an easy to use and cost-effective tool with a very high degree of concurrent validity. This software can be used to evaluate changes in velocity of training load in resistance training, which may be important for the prescription and monitoring of training programmes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1519/jsc.0000000000000563

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 14

  1. Casartelli, 2010, Validity and reliability of the Myotest accelerometric system for the assessment of vertical jump height, J Strength Cond Res, 24, 3186, 10.1519/JSC.0b013e3181d8595c · DOI · Paper page
  2. Comstock, 2011, Validity of the Myotest® in measuring force and power production in the squat and bench press, J Strength Cond Res, 25, 2293, 10.1519/JSC.0b013e318200b78c · DOI
  3. Cormie, 2007, Methodological concerns for determining power output in the jump squat, J Strength Cond Res, 21, 424
  4. Crewther, 2011, Validating two systems for estimating force and power, Int J Sports Med, 32, 254, 10.1055/s-0030-1270487 · doi:10.1055/s-0030-1270487
  5. Cronin, 2004, Reliability and validity of a linear position transducer for measuring jump performance, J Strength Cond Res, 18, 590
  6. Cronin, 2003, Force-velocity analysis of strength-training techniques and load: Implications for training strategy and research, J Strength Cond Res, 17, 148
  7. Fry, 2004, The role of resistance exercise intensity on muscle fibre adaptations, Sports Med, 34, 663, 10.2165/00007256-200434100-00004 · DOI · Paper page
  8. González-Badillo, 2011, The importance of movement velocity as a measure to control resistance training intensity, J Hum Kinet, 29A, 15, 10.2478/v10078-011-0053-6 · DOI · Paper page
  9. Jidovtseff, 2008, Validity and reliability of an inertial dynamometer using accelerometry, Sci Sport, 23, 94, 10.1016/j.scispo.2007.12.012 · doi:10.1016/j.scispo.2007.12.012
  10. Knudson, 2009, Significant and meaningful effects in sports biomechanics research, Sports Biomech, 8, 96, 10.1080/14763140802629966 · DOI
  11. Miletello, 2009, A biomechanical analysis of the squat between competitive collegiate, competitive high school, and novice powerlifters, J Strength Cond Res, 23, 1611, 10.1519/JSC.0b013e3181a3c6ef · DOI
  12. Rucci, 2010, Three types of kinematic feedback and the execution of the hang power clean, J Strength Cond Res, 24, 771, 10.1519/JSC.0b013e3181cbab96 · DOI
  13. Sato, 2012, The reliability of accelerometry to measure weightlifting performance, Sports Biomech, 11, 524, 10.1080/14763141.2012.724703 · doi:10.1080/14763141.2012.724703
  14. Sato, 2009, Validation of accelerometer for measuring sport performance, J Strength Cond Res, 23, 341, 10.1519/JSC.0b013e3181876a01 · doi:10.1519/jsc.0b013e3181876a01

Cited by

See all 47

Metadata

Authors
Sañudo, B., Rueda, D., Pozo-Cruz, B. D., de Hoyo, M., & Carrasco, L.
Venue
Journal of Strength and Conditioning Research
Published
2016-10
Volume
30
Issue
10
Pages
2934-2941
ISSN
1064-8011 (ISSN-L)
OpenAlex
W2334561080
Cited by
47
References
2
FWCI
2.51
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of a Video Analysis Software Package for Quantifying Movement Velocity in Resistance Exercises. https://app.cochat.ai/papers/10.1519/jsc.0000000000000563
The paper
Sañudo, B., Rueda, D., Pozo-Cruz, B. D., de Hoyo, M., & Carrasco, L. (2016). Validation of a Video Analysis Software Package for Quantifying Movement Velocity in Resistance Exercises. Journal of Strength and Conditioning Research. https://doi.org/10.1519/jsc.0000000000000563

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.