CoChat

Validity and Reliability of the Hexoskin Wearable Biometric Vest During Maximal Aerobic Power Testing in Elite Cyclists

Open access
Elliot, Catherine A., Hamlin, Michael J., Lizamore, Catherine A. · 2019 · Journal of Strength and Conditioning Research
Cited by 72

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Elliot, CA, Hamlin, MJ, and Lizamore, CA. Validity and reliability of the Hexoskin wearable biometric vest during maximal aerobic power testing in elite cyclists. J Strength Cond Res 33(5): 1437–1444, 2019—The purpose of this study was to investigate the validity and reliability of the Hexoskin vest for measuring respiration and heart rate (HR) in elite cyclists during a progressive test to exhaustion. Ten male elite cyclists (age 18–52 yrs, height 179.3 ± 6.0 cm, body mass 73.2 ± 9.1 kg, V o 2 max 60.7 ± 7.8 ml·kg·min−1, mean ± SD) conducted a maximal aerobic cycle ergometer test using a ramped protocol (starting at 100 W with 25 W increments each min to failure) during 2 separate occasions over a 3–4-day period. Compared with the criterion measure (MetaMax 3B) the Hexoskin vest showed mainly small typical errors (1.3–6.2%) for HR and breathing frequency (f), but larger typical errors (9.5–19.6%) for minute ventilation (V E) during the progressive test to exhaustion. The typical error indicating the reliability of the Hexoskin vest at moderate-intensity exercise between tests was small for HR (2.6–2.9%) and f (2.5–3.2%) but slightly larger for V E (5.3–7.9%). We conclude that the Hexoskin vest is sufficiently valid and reliable for measurements of HR and f in elite athletes during high-intensity cycling but the calculated V E value by the Hexoskin vest produced during such exercise should be used with caution because of the lower validity and reliability of this variable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1519/jsc.0000000000002005

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Research works printed but not linked: 15

  1. Borresen, 2008, Autonomic control of heart rate during and after exercise, Sports Med, 38, 633, 10.2165/00007256-200838080-00002 · DOI · Paper page
  2. Di Rienzo, 2010, Textile technology for the vital signs monitoring in telemedicine and extreme environments, IEEE Trans Inf Technol Biomed, 14, 711, 10.1109/TITB.2010.2048921 · DOI · Paper page
  3. Di Rienzo, 2013, Evaluation of a textile-based wearable system for the electrocardiogram monitoring in cardiac patients, Europace, 15, 607, 10.1093/europace/eus368 · DOI
  4. Flatt, 2016, Evaluating individual training adaptation with Smartphone-derived heart rate variability in a collegiate female soccer team, J Strength Cond Res, 30, 378, 10.1519/JSC.0000000000001095 · DOI
  5. Gastin, 2013, Quantification of tackling demands in professional Australian football using integrated wearable athlete tracking technology, J Sci Med Sport, 16, 589, 10.1016/j.jsams.2013.01.007 · DOI · Paper page
  6. Hailstone, 2011, Reliability and validity of the Zephyr™ BioHarness™ to measure respiratory responses to exercise, Meas Phys Educ Exerc Sci, 15, 293, 10.1080/1091367X.2011.615671 · DOI
  7. Hopkins, 2015, Spreadsheets for analysis of validity and reliability, Sportscience, 19, 36
  8. Kent, 2009, Validity and reliability of cardiorespiratory measurements recorded by the LifeShirt during exercise tests, Respir Physiol Neurobiol, 167, 162, 10.1016/j.resp.2009.03.013 · DOI
  9. Macfarlane, 2012, Validity, reliability and stability of the portable Cortex Metamax 3B gas analysis system, Eur J Appl Physiol, 112, 2539, 10.1007/s00421-011-2230-7 · DOI · Paper page
  10. Park, 2003, Enhancing the quality of life through wearable technology, IEEE Eng Med Biol Mag, 22, 41, 10.1109/MEMB.2003.1213625 · DOI · Paper page
  11. Saboul, 2016, A pilot study on quantification of training load: The use of HRV in training practice, Eur J Sport Sci, 16, 172, 10.1080/17461391.2015.1004373 · DOI
  12. Scherr, 2009, Effect of home-based telemonitoring using mobile phone technology on the outcome of heart failure patients after an episode of acute decompensation: Randomized controlled trial, J Med Internet Res, 11, e34, 10.2196/jmir.1252 · DOI · Paper page
  13. Smith, 2011, Variability and predictability of finals times of elite rowers, Med Sci Sports Exerc, 43, 2155, 10.1249/MSS.0b013e31821d3f8e · DOI · Paper page
  14. Smith, 2012, Measures of rowing performance, Sports Med, 42, 343, 10.2165/11597230-000000000-00000 · DOI
  15. Winterhalter, 2005, Development of electronic textiles to support networks, communications, and medical applications in future US Military protective clothing systems, IEEE Trans Inf Technol Biomed, 9, 402, 10.1109/TITB.2005.854508 · doi:10.1109/titb.2005.854508

Cited by

See all 72

Metadata

Authors
Elliot, C. A., Hamlin, M. J., & Lizamore, C. A.
Venue
Journal of Strength and Conditioning Research
Published
2019-05
Volume
33
Issue
5
Pages
1437-1444
ISSN
1064-8011 (ISSN-L)
OpenAlex
W2740222397
Cited by
72
References
6
FWCI
8.31
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validity and Reliability of the Hexoskin Wearable Biometric Vest During Maximal Aerobic Power Testing in Elite Cyclists. https://app.cochat.ai/papers/10.1519/jsc.0000000000002005
The paper
Elliot, C. A., Hamlin, M. J., & Lizamore, C. A. (2019). Validity and Reliability of the Hexoskin Wearable Biometric Vest During Maximal Aerobic Power Testing in Elite Cyclists. Journal of Strength and Conditioning Research. https://doi.org/10.1519/jsc.0000000000002005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.