CoChat

Body Composition Assessment in Male and Female Bodybuilders: A 4-Compartment Model Comparison of Dual-Energy X-Ray Absorptiometry and Impedance-Based Devices

Graybeal, Austin J., Moore, Michael Lane, Cruz, Megan R., Tinsley, Grant M. · 2020 · Journal of Strength and Conditioning Research
Cited by 59

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Graybeal, AJ, Moore, ML, Cruz, MR, and Tinsley, GM. Body composition assessment in male and female bodybuilders: a 4-compartment model comparison of dual-energy x-ray absorptiometry and impedance-based devices. J Strength Cond Res 34(6): 1676–1689, 2020—The purpose of this study was to examine the group and individual accuracy of body composition estimates obtained from multicompartment models, dual-energy x-ray absorptiometry (DXA), and several impedance-based devices in male and female bodybuilders. Twenty-seven male (n = 17; 4-compartment [4C] model fat-free mass index [FFMI]: 25.1 ± 1.8 kg·m−2; 4C body fat: 11.8 ± 4.4%) and female (n = 10; 4C FFMI: 18.3 ± 1.4 kg·m−2; 4C body fat: 19.7 ± 4.9%) bodybuilders underwent duplicate assessments using DXA, bioimpedance spectroscopy (BIS), electrical impedance myography (EIM), and 3 bioelectrical impedance analysis (BIA) devices. In addition to utilizing standard output, multicompartment models were generated. For each method, body fat %, FFM, and fat mass were compared with the reference 4C model for the evaluation of group and individual errors. The 3-compartment model with a BIS body water estimate produced the lowest standard error of the estimate, total error (TE), and 95% limits of agreement (LOA) for all variables, although some alternative methods had lower constant error (CE). In general, multicompartment models with BIS or multifrequency BIA body water estimates produced more accurate body composition estimates than single assessment techniques (i.e., DXA, BIS, EIM, and BIA). Single assessment techniques produced low CE and TE for some body composition variables. However, proportional bias was observed for DXA and BIS. All single assessment techniques produced LOA large enough to make the utility of these methods questionable in individual athletes. Appropriate caution should be used when interpreting and utilizing body composition estimates in muscular physique athletes, particularly at the individual level.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1519/jsc.0000000000002831

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 59

Metadata

Authors
Graybeal, A. J., Moore, M. L., Cruz, M. R., & Tinsley, G. M.
Venue
Journal of Strength and Conditioning Research
Published
2020-06
Volume
34
Issue
6
Pages
1676-1689
ISSN
1064-8011 (ISSN-L)
OpenAlex
W2916033170
Cited by
59
References
11
FWCI
2.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Body Composition Assessment in Male and Female Bodybuilders: A 4-Compartment Model Comparison of Dual-Energy X-Ray Absorptiometry and Impedance-Based Devices. https://app.cochat.ai/papers/10.1519/jsc.0000000000002831
The paper
Graybeal, A. J., Moore, M. L., Cruz, M. R., & Tinsley, G. M. (2020). Body Composition Assessment in Male and Female Bodybuilders: A 4-Compartment Model Comparison of Dual-Energy X-Ray Absorptiometry and Impedance-Based Devices. Journal of Strength and Conditioning Research. https://doi.org/10.1519/jsc.0000000000002831

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.