An analysis of axon caliber within the optic nerve of the cat: evidence of size groupings and regional organization
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Axon size in the optic nerves of three adult cats was measured using an accurate planimetric method. A sample of the axon complement was obtained from sets of more than 125 electron micrographs taken at each nerve. In contrast to previous reports, the distribution of axon diameter, as estimated from measurements of axonal cross-sectional area was clearly bimodal. The group of finest axons had a mode at approximately 1 micrometer, and the mode of the group of intermediate size axons was approximately 2 micrometers. Fibers with diameters larger than 3.5 micrometers formed the extensive tail of the distribution. The proportions of large, intermediate, and small axons were estimated to be 5%, 45%, and 50%. These groups probably correspond to the alpha, beta, and gamma classes of retinal ganglion cells. Regional distributions of axon caliber were also bimodal and, in a few instances, even trimodal. A peripheral crescent of each nerve contained a large number of fine fibers. Mean fiber diameter within discrete regions of the optic nerve varied inversely with the density of axon packing. The thickness of the myelin sheath was highly correlated with the inner fiber diameter, hence, myelin sheath width was also distributed in a bimodal manner. These results furnish the first clear evidence that the distribution of fiber caliber within the cat's optic nerve mirrors the principal classes of retinal ganglion cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The contrast sensitivity of retinal ganglion cells of the cat
Enroth-Cugell, C., & Robson, J. G. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008107 · Cited by 2,625
The conduction properties of axons in central white matter
Waxman, S. G., & Swadlow, H. A. (1977) · Progress in Neurobiology · doi:10.1016/0301-0082(77)90009-0 · Cited by 109
Cited by
The energetics of CNS white matter
Harris, J. J., & Attwell, D. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.3430-11.2012 · Cited by 505
Ion-channel noise places limits on the miniaturization of the brain's wiring
Faisal, A. A., White, J. A., & Laughlin, S. B. (2005) · Current Biology · doi:10.1016/j.cub.2005.05.056 · Cited by 216
Elimination of neurons from the rhesus monkey's lateral geniculate nucleus during development
Williams, R. W., & Rakic, P. (1988) · Journal of Comparative Neurology · doi:10.1002/cne.902720310 · Cited by 124
Self-citationMetabolic Vulnerability in the Neurodegenerative Disease Glaucoma
Inman, D. M., & Harun-Or-Rashid, M. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00146 · Cited by 88
Genetic Control of Interconnected Neuronal Populations in the Mouse Primary Visual System
Seecharan, D. J., Kulkarni, A. L., Lu, L., Rosen, G. D., & Williams, R. W. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-35-11178.2003 · Cited by 43
“The size of RGC axons is a good surrogate measure of cell body size and even of ganglion cell subtype (Johnson et al., 1998; Williams and Chalupa, 1983).”
BackgroundSelf-citation
Metadata
- Authors
- Williams, R., & Chalupa, L.
- Venue
- The Journal of Neuroscience
- Publisher
- Society for Neuroscience
- Published
- 1983-08-01
- Volume
- 3
- Issue
- 8
- Pages
- 1554-1564
- ISSN
- 0270-6474 (ISSN-L)
- 1529-2401
- OpenAlex
- W1935698925
- Cited by
- 95
- References
- 2
- FWCI
- 3.89
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An analysis of axon caliber within the optic nerve of the cat: evidence of size groupings and regional organization. https://app.cochat.ai/papers/10.1523/jneurosci.03-08-01554.1983
- The paper
- Williams, R., & Chalupa, L. (1983). An analysis of axon caliber within the optic nerve of the cat: evidence of size groupings and regional organization. The Journal of Neuroscience. https://doi.org/10.1523/jneurosci.03-08-01554.1983
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.