Two-Color Far-Field Fluorescence Nanoscopy
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Self-citationBeiträge zur Theorie des Mikroskops und der mikroskopischen Wahrnehmung
Abbe, E. (1873) · Archiv für Mikroskopische Anatomie · doi:10.1007/bf02956173 · Cited by 2,724
Jares-Erijman, E. A., & Jovin, T. M. (2003) · Nature Biotechnology · doi:10.1038/nbt896 · Cited by 1,824
STED microscopy reveals that synaptotagmin remains clustered after synaptic vesicle exocytosis
Willig, K. I., Rizzoli, S. O., Westphal, V., Jahn, R., & Hell, S. W. (2006) · Nature · doi:10.1038/nature04592 · Cited by 1,225
Self-citationHell, S. W. (2003) · Nature Biotechnology · doi:10.1038/nbt895 · Cited by 1,003
Self-citationMacromolecular-scale resolution in biological fluorescence microscopy
Donnert, G., Keller, J., Medda, R., Andrei, M. A., Rizzoli, S. O., Lührmann, R., Jahn, R., Eggeling, C., & Hell, S. W. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604965103 · Cited by 527
Self-citationNanoscale Resolution in the Focal Plane of an Optical Microscope
Westphal, V., & Hell, S. W. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.143903 · Cited by 502
Self-citationAn investigation of mitochondrial inner membranes by rapid-freeze deep-etch techniques.
Allen, R. D., Schroeder, C. C., & Fok, A. K. (1989) · The Journal of cell biology · doi:10.1083/jcb.108.6.2233 · Cited by 177
STED microscopy resolves nanoparticle assemblies
Willig, K. I., Keller‐Findeisen, J., Bossi, M. L., & Hell, S. W. (2006) · New Journal of Physics · doi:10.1088/1367-2630/8/6/106 · Cited by 136
Self-citationEvidence for Early Endosome‐like Fusion of Recently Endocytosed Synaptic Vesicles
Rizzoli, S. O., Bethani, I., Zwilling, D., Wenzel, D., Siddiqui, T. J., Brandhorst, D., & Jahn, R. (2006) · Traffic · doi:10.1111/j.1600-0854.2006.00466.x · Cited by 65
Self-citationHolmes, T. J., & Liu, Y.-H. (1989) · Applied Optics · doi:10.1364/ao.28.004930 · Cited by 53
Cited by
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Self-citationSuper-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Multicolor Super-Resolution Imaging with Photo-Switchable Fluorescent Probes
Bates, M., Huang, B., Dempsey, G. T., & Zhuang, X. (2007) · Science · doi:10.1126/science.1146598 · Cited by 1,504
Fluorescent probes for super-resolution imaging in living cells
Fernández-Suárez, M., & Ting, A. Y. (2008) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2531 · Cited by 1,306
A guide to super-resolution fluorescence microscopy
Schermelleh, L., Heintzmann, R., & Leonhardt, H. (2010) · Journal of Cell Biology · doi:10.1083/jcb.201002018 · Cited by 1,255
Metadata
- Authors
- Donnert, G., Keller, J., Wurm, C. A., Rizzoli, S. O., Westphal, V., Schönle, A., Jahn, R., Jakobs, S., Eggeling, C., & Hell, S. W.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2007-04
- Volume
- 92
- Issue
- 8
- Pages
- L67-L69
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2070918388
- Cited by
- 256
- References
- 11
- FWCI
- 11.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.