Real-Time Continuous Glucose Monitoring in Pediatric Patients During and After Cardiac Surgery
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVES. Given the demonstrated benefit of euglycemia in critically ill patients as well as the risk for hypoglycemia during insulin infusion in children, we sought to validate a subcutaneous sensor for real-time continuous glucose monitoring in pediatric patients during and after cardiac surgery. METHODS. Children up to 36 months of age who were undergoing cardiac bypass surgery were recruited. After anesthetic induction, a continuous glucose-monitoring system sensor (CGMS, Medtronic Minimed, Northridge, CA) was inserted subcutaneously. Sensors remained in place for up to 72 hours. Arterial blood glucose was measured intermittently in the central laboratory (Bayer Rapidlab 860, Tarrytown, NY). Sensor data, after prospective calibration with 6-hourly laboratory values using the proprietary Medtronic Minimed Guardian RT algorithm, were compared with all laboratory glucose values. Statistical analysis was performed to test whether sensor performance was affected by body temperature, inotrope dose, or body-wall edema. RESULTS. Twenty patients were enrolled in the study for a total of 40 study days and 246 paired sensor and laboratory glucose values. Consensus error grid analysis demonstrated that 72.0% of sensor value comparisons were within zone A (no effect on clinical action), and 27.6% of comparisons were within zone B (altered clinical action of little or no effect on outcome), with a mean absolute relative deviation of 17.6% for all comparisons. One comparison (0.4%) was in zone C (altered clinical action likely to affect outcome). No significant correlations were found between sensor performance and body temperature, inotrope dose, or body-wall edema. All patients tolerated the sensors well without bleeding or tissue reaction. CONCLUSIONS. Guardian RT real-time subcutaneous blood glucose measurement is safe and potentially useful for continuous glucose monitoring in critically ill children. Subcutaneous sensors performed well in the setting of hypothermia, inotrope use, and edema. These sensors facilitate identifying and following the effects of interventions to control blood glucose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Furnary, A. P., Gao, G., Grunkemeier, G. L., Wu, Y., Zerr, K. J., Bookin, S. O., Floten, H. S., & Starr, A. (2003) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2003.181 · Cited by 1,130
Wernovsky, G., Wypij, D., Jonas, R. A., Mayer, J. E., Hanley, F. L., Hickey, P. R., Walsh, A. Z., Chang, A. C., Castañeda, A. R., Newburger, J. W., et al. (1995) · Circulation · doi:10.1161/01.cir.92.8.2226 · Cited by 1,010
Parkes, J. L., Slatin, S. L., Pardo, S., & Ginsberg, B. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.8.1143 · Cited by 620
Cited by
Jacobi, J., Bircher, N., Krinsley, J., Agus, M., Braithwaite, S. S., Deutschman, C., Freire, A. X., Geehan, D., Kohl, B., Nasraway, S. A., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182653269 · Cited by 571
Self-citationVlasselaers, D., Milants, I., Desmet, L., Wouters, P. J., Vanhorebeek, I., van den Heuvel, I., Mesotten, D., Casaer, M. P., Meyfroidt, G., Ingels, C., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60044-1 · Cited by 554
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390
“56 57–60 What Does the Future Hold?”
Continuous Glucose Monitoring Systems: A Review
Vashist, S. (2013) · Diagnostics · doi:10.3390/diagnostics3040385 · Cited by 261
Continuous glucose monitoring: an Endocrine Society Clinical Practice Guideline
Klonoff, D. C., Buckingham, B., Christiansen, J. S., Montori, V. M., Tamborlane, W. V., Vigersky, R. A., & Wolpert, H. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2756 · Cited by 211
Metadata
- Authors
- Piper, H. G., Alexander, J. L., Shukla, A., Pigula, F., Costello, J. M., Laussen, P. C., Jaksic, T., & Agus, M. S. D.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2006-09-01
- Volume
- 118
- Issue
- 3
- Pages
- 1176-1184
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W2029237990
- Cited by
- 137
- References
- 3
- FWCI
- 5.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-Time Continuous Glucose Monitoring in Pediatric Patients During and After Cardiac Surgery. https://app.cochat.ai/papers/10.1542/peds.2006-0347
- The paper
- Piper, H. G., Alexander, J. L., Shukla, A., Pigula, F., Costello, J. M., Laussen, P. C., Jaksic, T., & Agus, M. S. D. (2006). Real-Time Continuous Glucose Monitoring in Pediatric Patients During and After Cardiac Surgery. Pediatrics. https://doi.org/10.1542/peds.2006-0347
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.