Near-Infrared Imaging in Intravenous Cannulation in Children: A Cluster Randomized Clinical Trial
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Intravenous cannulation is a widespread medical procedure that can be difficult in children. Visualization of veins with near-infrared (NIR) light might support intravenous cannulation. Therefore, we investigated the effectiveness of an NIR vascular imaging system (VascuLuminator) in facilitating intravenous cannulation in children in the operating room. METHODS: This was a pragmatic, cluster randomized clinical trial in all consecutive children (0–18 years) scheduled for elective surgery and in need of intravenous cannulation at a tertiary pediatric referral hospital. Daily operating rooms (770 patients) were randomized for allocation of the VascuLuminator or control group. The primary outcome was success at first attempt; the secondary outcome was time to successful cannulation. RESULTS: Success at first attempt was 70% (171/246) with and 71% (175/245) without the use of the VascuLuminator (P = .69). Time to successful cannulation was 162 (±14) seconds and 143 (±15) seconds respectively (P = .26). In 83.3%, the vein of first choice was visible with the VascuLuminator. CONCLUSIONS: Although it was possible to visualize veins with NIR in most patients, the VascuLuminator did not improve success rate or time to obtain intravenous cannulation. There are 3 possible explanations for this result: first, it could be that localization of the vein is not the main problem, and therefore visualization is not a solution; second, the type of system used in this study could be less than optimal; and, third, the choice of the patient population in this study could be inappropriate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The validity and practicality of sun-reactive skin types I through VI
Fitzpatrick, T. B. (1988) · Archives of Dermatology · doi:10.1001/archderm.1988.01670060015008 · Cited by 4,339
A pragmatic–explanatory continuum indicator summary (PRECIS): a tool to help trial designers
Thorpe, K. E., Zwarenstein, M., Oxman, A. D., Treweek, S., Furberg, C. D., Altman, D. G., Tunis, S., Bergel, E., Harvey, I., Magid, D. J., et al. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2008.12.011 · Cited by 1,389
Simpson, C. R., Kohl, M., Essenpreis, M., & Cope, M. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/9/003 · Cited by 651
Costantino, T. G., Parikh, A. K., Satz, W. A., & Fojtik, J. P. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.12.026 · Cited by 435
Peripheral Difficult Venous Access in Children
Rauch, D., Dowd, D., Eldridge, D., Mace, S., Schears, G., & Yen, K. (2009) · Clinical Pediatrics · doi:10.1177/0009922809335737 · Cited by 80
Glynn, R. J., Brookhart, M. A., Stedman, M., Avorn, J., & Solomon, D. H. (2007) · Medical Care · doi:10.1097/mlr.0b013e318070c0a0 · Cited by 72
Cited by
Waller, D., Mondy, P., Brama, T., Fisher, J., King, A., Malkov, K., Wall‐Smith, D., Ryan, L., & Irving, D. O. (2016) · Vox Sanguinis · doi:10.1111/vox.12407 · Cited by 9
Hosseini, S. J., Firooz, M., Yazdi, K., Abdollahi, M., Hosseini, S. R., & Ramezani, M. (2025) · The Journal of Vascular Access · doi:10.1177/11297298241259843 · Cited by 6
Fehr, G., Rigali, M., Weller, G., Grap, S. M., Coleman, M., Parekh, U., Chinchilli, V. M., & Dalal, P. G. (2023) · Children · doi:10.3390/children10101652 · Cited by 5
“Most studies on transillumination techniques included patients from a wide age group [2,4–6] and failed to report superiority over the traditional cannulation technique [2,4,5].”
BackgroundResultInfluential
Metadata
- Authors
- Cuper, N. J., de Graaff, J. C., Verdaasdonk, R. M., & Kalkman, C. J.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2013-01-01
- Volume
- 131
- Issue
- 1
- Pages
- e191-e197
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W2122419535
- Cited by
- 40
- References
- 6
- FWCI
- 4.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Near-Infrared Imaging in Intravenous Cannulation in Children: A Cluster Randomized Clinical Trial. https://app.cochat.ai/papers/10.1542/peds.2012-0968
- The paper
- Cuper, N. J., de Graaff, J. C., Verdaasdonk, R. M., & Kalkman, C. J. (2013). Near-Infrared Imaging in Intravenous Cannulation in Children: A Cluster Randomized Clinical Trial. Pediatrics. https://doi.org/10.1542/peds.2012-0968
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.