CoChat

Neonatal Pulse Oximetry: Accuracy and Reliability

Hay, William W., Brockway, Julia M., Eyzaguirre, Mario · 1989 · Pediatrics
Cited by 141

The DOI matches its Crossref record.

Abstract

Pulse oximetry has gained widespread use in neonatal oxygen monitoring. However, because specific morbidity in neonates has been related to abnormal levels of oxygen partial pressure (Pao2), it is essential to demonstrate that pulse oxygen saturation values (Spo2) are highly accurate and reflect with precision the simultaneous Pao2. In this report, data is presented that describe the accuracy of the Ohmeda Biox 3700 pulse oximeter. Spo2 was highly correlated with arterial blood oxygen saturation (r = .99) measured on arterial (catheter) blood using a two-wavelength Radiometer OSM2 Hemoximeter. When compared with Pao2, Spo2 values of 92% ± 3% (mean ± range) excluded all of the measured Pao2 values less than 45 mm Hg and greater than 100 mm Hg. Spo2-tcPo2 (transcutaneous Po2) and Spo2-Pao2 (catheter or percutaneous arterial Po2) correlations showed that bronchopulmonary dysplasia, percutaneous arterial sampling, and nipple feeding skewed the tcPo2 but not the Pao2 correlations with Spo2, indicating that Spo2 is not sensitive to peripheral factors that affect tcPo2. Spo2-Pao2 correlation was not affected by gestational age. A high degree of accuracy of Spo2 values and Spo2 prediction of normal appearing Pao2 values are defined by these results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1542/peds.83.5.717

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Hay, W. W., Brockway, J. M., & Eyzaguirre, M.
Venue
Pediatrics
Published
1989-05-01
Volume
83
Issue
5
Pages
717-722
ISSN
  • 0031-4005 (ISSN-L)
  • 1098-4275
OpenAlex
W4206184379
Cited by
141
References
0
FWCI
8.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.