Racial discrepancy in pulse oximeter accuracy in preterm infants

Open access
Vesoulis, Zachary, Tims, Anna, Lodhi, Hafsa, Lalos, Natasha, Whitehead, Halana·2022·Journal of Perinatology

Abstract

Objective Pulse oximetry is commonly used in Neonatology, however recent adult data suggest racial disparity in accuracy, with overestimation of oxygen saturation for Black patients.Study design Black and White infants <32 weeks gestation underwent simultaneous arterial blood gas and pulse oximetry measurement. Error by race was examined using mean bias, A rms, Bland-Altman, and linear/non-linear analysis.Results A total of 294 infants (124 Black, 170 White) were identified with mean GA of 25.8 ± 2.1 weeks and mean BW of 845 ± 265 grams, yielding 4387 SaO 2-SpO 2 datapoints. SpO 2 overestimation, measured by mean bias, was 2.4-fold greater for Black infants and resulted in greater occult hypoxemia (SpO 2 > 90% when SaO 2 < 85%; 9.2% vs. 7.7% of samples). Sensitivity and specificity for detection of true hypoxemia were similar between groups (39 vs. 38%; 81 vs. 78%).Conclusion There is a modest but consistent difference in SpO 2 error between Black and White infants, with increased incidence of occult hypoxemia in Black infants.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41372-021-01230-3

Cites

65 of 65 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • More recent studies have revealed that dark skin pigmentation influences the accuracy and performance of pulse oximeter devices, resulting in overestimations, with increased incidence in the risk for occult hypoxemia (SO2<88% despite normal SpO2>92%).

    “More recent studies have also revealed that dark skin pigmentation influences the accuracy and performance of pulse oximeters devices, resulting in overestimations [17,49,50,51,52,53] with increased incidence in the risk for occult hypoxemia (SO2<88% despite normal SpO2>92%) [54,55].”
  • Recent studies have shown a positive bias in oxygen saturation measurements in patients with darkly pigmented skin, particularly under low saturation conditions.

    “Recent studies have shown a positive bias in oxygen saturation measurements in patients with darkly pigmented skin, particularly under low saturation conditions.”
  • Ancestry descriptors were used in 11 studies (29.73%).

    “On the other hand, ancestry descriptors were used in 11 studies (29.73%) [17,21,23,24,41,51,53,61,75,82,93]”
  • Pulse oximetry performance in the dark-skinned population may lead to overestimations with increased incidence of occult hypoxemia and risk of negative health effects from diseases like COVID-19.

    “To sum up, we conclude that pulse oximetry performance in the dark-skinned population may lead to overestimations with increased incidence of occult hypoxemia and risk of negative health effects from diseases like COVID-19 [51,53,55].”
  • Two studies found a small but consistent skin pigmentation disparity in SpO2 measurements with values that may be falsely high in dark-skinned preterm infants.

    “The other two studies found a small but consistent skin pigmentation disparity in SpO2 measurements with values that may be falsely high in dark-skinned preterm infants [51,74].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. [32]Montagna W, Prota G, Kenney JA. Jr Black Skin: Structure and Function. Elsevier Science: Saint Louis, 2014. http://qut.eblib.com.au/patron/FullRecord.aspx?p=1190974 (accessed 5 Feb 2021).

Cited by

Sorted by citations

Authors
Vesoulis, Z., Tims, A., Lodhi, H., Lalos, N., & Whitehead, H.
Affiliations
Washington University in St. Louis (US)
Corresponding author
Vesoulis, Zachary
Venue
Journal of Perinatology
Published
2021-10-12
Volume
42
Issue
1
Pages
79-85
ISSN
  • 0743-8346 (ISSN-L)
  • 1476-5543
OpenAlex
W3205068012
Cited by
120
References
65
Citations by year
2026: 10 · 2025: 23 · 2024: 24 · 2023: 25 · 2022: 37
FWCI
6.53
Type
journal article
Language
en
Open access
Locations
  • Journal of Perinatology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
U.S. Department of Health & Human Services | NIH | National Institute of Neurological Disorders and Stroke (K23 NS111086)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Neonatal Respiratory Health Research
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Neonatal Health and Biochemistry
Keywords
pulse oximetry, racial disparities, preterm infants, oxygen saturation, hypoxemia detection, Black infants, measurement accuracy, neonatal monitoring
MeSH terms
Adult, Hypoxia, Blood Gas Analysis, Humans, Infant, Newborn, Infant, Premature, Oximetry, Oxygen

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review