Neonatal and Pediatric Pulse Oximetry
Abstract
The pulse oximeter has become a vital instrument in the care of infants and children with cardiopulmonary disease. Recent advances in pulse oximetry technology have improved some aspects of pulse oximeter performance. However, the reliability, accuracy, and clinical utility of pulse oximetry remain problematic in some types of patients under certain conditions. Improved signal processing technology has substantially improved the ability of certain oximeters to work reliably under conditions of poor perfusion and motion artifact. There is a growing body of evidence describing the effect of pulse oximeter utilization on processes and outcomes. This article describes the principles, limitations, current state of oximetry technology, and the impact of oximetry data and alarms on diagnosis and clinical decision-making.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lawless (1994) · doi:10.1097/00003246-199406000-00017 · Cited by 406
Chambrin, M.-C., Ravaux, P., Calvelo-Aros, D., Jaborska, A., Chopin, C., & Boniface, B. (1999) · Intensive Care Medicine · doi:10.1007/s001340051082 · Cited by 227
Ries, A. L., Prewitt, L. M., & Johnson, J. J. (1989) · Chest · doi:10.1378/chest.96.2.287 · Cited by 145
Reliability of noninvasive oximetry in black subjects during exercise and hypoxia
Zeballos, R. J., & Weisman, I. M. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.6.1240 · Cited by 108
A clinical evaluation of the accuracy of the Nellcor N-100 and Ohmeda 3700 pulse oximeters
Cecil, W. T., Thorpe, K. J., Fibuch, E. E., & Tuohy, G. F. (1988) · Journal of Clinical Monitoring · doi:10.1007/bf01618105 · Cited by 51
Cited by
Diagnosis and Management of Bronchiolitis
Bronchiolitis, S. O. D. A. M. O. (2006) · Pediatrics · doi:10.1542/peds.2006-2223 · Cited by 1,062
European Resuscitation Council Guidelines 2021: Paediatric Life Support
Van de Voorde, P., Turner, N. M., Djakow, J., de Lucas, N., Martinez-Mejias, A., Biarent, D., Bingham, R., Brissaud, O., Hoffmann, F., Johannesdottir, G. B., et al. (2021) · Resuscitation · doi:10.1016/j.resuscitation.2021.02.015 · Cited by 448
Pulse oximetry: fundamentals and technology update
Nitzan, M., Romem, A., & Koppel, R. (2014) · Medical Devices: Evidence and Research · doi:10.2147/mder.s47319 · Cited by 438
Mahle, W. T., Newburger, J. W., Matherne, G. P., Smith, F. C., Hoke, T. R., Koppel, R., Gidding, S. S., Beekman, R. H., Grosse, S. D., & on behalf of the American Heart Association Congenital Heart Defects Committee of the Council on Cardiovascular Disease in the Young, C. O. C. N. (2009) · Pediatrics · doi:10.1542/peds.2009-1397 · Cited by 346
Mahle, W. T., Newburger, J. W., Matherne, G. P., Smith, F. C., Hoke, T. R., Koppel, R., Gidding, S. S., Beekman, R. H., & Grosse, S. D. (2009) · Circulation · doi:10.1161/circulationaha.109.192576 · Cited by 286
Metadata
- Authors
- Salyer, J. W.
- Venue
- Respiratory Care
- Publisher
- American Association for Respiratory Care
- Published
- 2003-04-01
- Volume
- 48
- Issue
- 4
- Pages
- 386-398
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W2118959920
- Cited by
- 183
- References
- 5
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Neonatal and Pediatric Pulse Oximetry. https://app.cochat.ai/papers/10.4187/respcare.03480386
- The paper
- Salyer, J. W. (2003). Neonatal and Pediatric Pulse Oximetry. Respiratory Care. https://doi.org/10.4187/respcare.03480386
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.