Applications of sensory feedback in motorized upper extremity prosthesis: a review
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Dexterous hand movement is possible due to closed loop control dependent on efferent motor output and afferent sensory feedback. This control strategy is significantly altered in those with upper limb amputation as sensations of touch and movement are inherently lost. For upper limb prosthetic users, the absence of sensory feedback impedes efficient use of the prosthesis and is highlighted as a major factor contributing to user rejection of myoelectric prostheses. Numerous sensory feedback systems have been proposed in literature to address this gap in prosthetic control; however, these systems have yet to be implemented for long term use. Methodologies for communicating prosthetic grasp and touch information are reviewed, including discussion of selected designs and test results. With a focus on clinical and translational challenges, this review highlights and compares techniques employed to provide amputees with sensory feedback. Additionally, promising future directions are discussed and highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Proske, U., & Gandevia, S. C. (2012) · Physiological Reviews · doi:10.1152/physrev.00048.2011 · Cited by 2,223 · cited 1×
“It is believed that the vibratory stimulus induces muscle spindle activity [79]; consequently, the direction of illusionary movement will be experienced as though the stimulated muscle group is being stretched (FIGURE 10).”
BackgroundJohansson, R. S., & Westling, G. (1987) · Experimental Brain Research · doi:10.1007/bf00236210 · Cited by 865 · cited 1×
“Thus, the corresponding sensory information may be perceived as unnatural and may require additional time, training and attention to effectively exploit [73,74].”
BackgroundElectrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583 · cited 2×
“Although promising, TR feedback techniques, first published in 2004, are in their relative infancy compared with other feedback methods [64,69].”
BackgroundDirect neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Consumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519 · cited 1×
“About 29–39% of upper limb amputees will discontinue usage of their prosthesis [10] with lack of sensory feedback often being highlighted as a major contributing factor [2,6,11,12].”
BackgroundSensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Double nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396 · cited 1×
“Through manipulation of the electrical frequency and current, investigators are able to influence the location, magnitude and modality of these elicited sensations [56,58].”
BackgroundPatient specific ankle-foot orthoses using rapid prototyping
Mavroidis, C., Ranky, R. G., Sivak, M. L., Patritti, B. L., DiPisa, J., Caddle, A., Gilhooly, K., Govoni, L., Sivak, S., Lancia, M., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-1 · Cited by 361
Horch, K., Meek, S., Taylor, T. G., & Hutchinson, D. T. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2162635 · Cited by 194 · cited 1×
“Neither substitution nor modalitymatched methods provide input through the original sensory pathways of the amputee [55].”
Background
Cited by
Literature Review on Needs of Upper Limb Prosthesis Users
Cordella, F., Ciancio, A. L., Sacchetti, R., Davalli, A., Cutti, A. G., Guglielmelli, E., & Zollo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00209 · Cited by 752
Losey, D. P., McDonald, C. G., Battaglia, E., & O'Malley, M. K. (2018) · Applied Mechanics Reviews · doi:10.1115/1.4039145 · Cited by 392
Wendelken, S., Page, D. M., Davis, T., Wark, H. A. C., Kluger, D. T., Duncan, C., Warren, D. J., Hutchinson, D. T., & Clark, G. A. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0320-4 · Cited by 216
A Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
“[33] presented the most recent review that had a major focus on non-invasive feedback methods for prosthetic hands in 2014, which discussed literature up until December 2013.”
BackgroundA review of invasive and non-invasive sensory feedback in upper limb prostheses
Svensson, P., Wijk, U., Björkman, A., & Antfolk, C. (2017) · Expert Review of Medical Devices · doi:10.1080/17434440.2017.1332989 · Cited by 192
Metadata
- Authors
- Schofield, J. S., Evans, K. R., Carey, J. P., & Hebert, J. S.
- Venue
- Expert Review of Medical Devices
- Publisher
- Informa UK Limited
- Published
- 2014-06-13
- Volume
- 11
- Issue
- 5
- Pages
- 499-511
- ISSN
- 1743-4440 (ISSN-L)
- 1745-2422
- OpenAlex
- W1973768714
- Cited by
- 155
- References
- 19
- FWCI
- 3.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Applications of sensory feedback in motorized upper extremity prosthesis: a review. https://app.cochat.ai/papers/10.1586/17434440.2014.929496
- The paper
- Schofield, J. S., Evans, K. R., Carey, J. P., & Hebert, J. S. (2014). Applications of sensory feedback in motorized upper extremity prosthesis: a review. Expert Review of Medical Devices. https://doi.org/10.1586/17434440.2014.929496
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.