The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Abstract
The human hand is a complex system, with a large number of degrees of freedom (DoFs), sensors embedded in its structure, actuators and tendons, and a complex hierarchical control. Despite this complexity, the efforts required to the user to carry out the different movements is quite small (albeit after an appropriate and lengthy training). On the contray, prosthetic hands are just a pale replication of the natural hand, with significantly reduced grasping capabilities and no sensory information delivered back to the user. Several attempts have been carried out to develop multifunctional prosthetic devices controlled by electromyographic (EMG) signals (myoelectric hands), harness (kinematic hands), dimensional changes in residual muscles, and so forth, but none ofthese methods permits the "natural" control of more than two DoFs. This article presents a review of the traditional methods used to control artificial hands by means of EMG signal, in both the clinical and research contexts, and introduces what could be the future developments in the control strategy of these devices.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the formal scheme for the acquisition and analysis of EMG signals for the control of prosthetic devices is composed of several modules (Zecca et al., 2002) : (1) signal conditioning, pre-processing, and detection of onset movement (Micera et al., 1999) ; (2) feature extraction; (3) dimensionality reduction; (4) pattern recognition; and (5) off-line and on-line learning.”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Zecca et al., 2002
In the citing paper
“Among the different approaches for restoring the link between the external world and the nervous system, the use of implantable intrafascicular PNS interfaces is of great potential, as confirmed in previous experiments in humans [6,7].”
From Decoding of grasping information from neural signals recorded using peripheral intrafascicular interfaces (2011) · cites this paper as [7]
In the citing paper
“In fact, after appropriate control in experimental models to test their biocompatibility and efficacy [18], LIFEs have been recently used to control artificial devices [6,7,22-25] showing good results during short-term trials with human amputees.”
From Decoding of grasping information from neural signals recorded using peripheral intrafascicular interfaces (2011) · cites this paper as [7]
Citations
Cites
The publisher hasn’t deposited this paper’s reference list.
Cited by
Sorted by citations
Items 301–400 of 607
Estimation of continuous thumb angle and force using electromyogram classification
Siddiqi, A. R., & Sidek, S. N. (2016) · International Journal of Advanced Robotic Systems · doi:10.1177/1729881416658179 · Cited by 13
Stegman, K. J., Djurickovic, S., & Dechev, N. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2013.09.029 · Cited by 13
Neighborhood denoising for learning high-dimensional grasping manifolds
Tsoli, A., & Jenkins, O. C. (2008) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2008.4651228 · Cited by 13
Multimodal sensor-based human-robot collaboration in assembly tasks
Male, J., Al, G. A., Shabani, A., & Martínez-Hernández, U. (2022) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc53654.2022.9945532 · Cited by 12
Finger pinch force estimation through muscle activations using a surface EMG sleeve on the forearm
Fang, Y., Ju, Z., Zhu, X., & Liu, H. (2014) · IEEE International Conference on Fuzzy Systems (FUZZ-IEEE) · doi:10.1109/fuzz-ieee.2014.6891790 · Cited by 12
Huang, G., Xian, Z., Zhang, Z., Li, S., & Zhu, X. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.04.011 · Cited by 12
Introduction to Upper Limb Prosthetics
Graimann, B., & Dietl, H. (2013) · Wiley eBooks · doi:10.1002/9781118628522.ch14 · Cited by 12
Forearm functional movement recognition using spare channel surface electromyography
Zhang, Z., Wong, C., & Yang, G. (2013) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2013.6575507 · Cited by 11
Lv, S., Li, Z., Huang, J., & Shi, P. J. (2023) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2023.3310524 · Cited by 11
Recognition of motion of human upper limb using sEMG in real time: Towards bilateral rehabilitation
Song, Z., Guo, S., Pang, M., & Zhang, S. (2012) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2012.6491165 · Cited by 11
Multimodal sensor controlled three Degree of Freedom transradial prosthesis
Ohnishi, K., Kajitani, I., Morio, T., & Takagi, T. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650467 · Cited by 11
Hybrid control strategy for five-fingered smart prosthetic hand
Chen, C.-H., Naidu, D. S., Gracia, A. P., & Schoen, M. P. (2009) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2009.5400771 · Cited by 11
Real‐time control of dielectric elastomer actuators via bioelectric and biomechanical signals
Carpi, F., Raspopović, S., Frediani, G., & Rossi, D. D. (2009) · Polymer International · doi:10.1002/pi.2757 · Cited by 11
Endpoint Control for a Powered Shoulder Prosthesis
Phillips, S. L., Resnik, L. J., Fantini, C. M., & Latlief, G. A. (2013) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0000000000000006 · Cited by 11
Basic hand action classification based on surface EMG using autoregressive reflection coefficient
Fattah, S. A., Iqbal, O., Zahin, S., Shahnaz, C., & Rosul, G. (2017) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2017.8228071 · Cited by 11
Local binary patterns for noise-tolerant sEMG classification
Tabatabaei, S. M., & Chalechale, A. (2018) · Signal Image and Video Processing · doi:10.1007/s11760-018-1374-x · Cited by 11
Hameed, H. K., Hasan, W. Z. W., Shafie, S. B., Ahmad, S. A., & Jaafar, H. (2018) · IEEE International Conference on Smart Instrumentation, Measurement and Applications (ICSIMA) · doi:10.1109/icsima.2018.8688753 · Cited by 11
Contreras-Castañeda, M. A., Holgado-Terriza, J. A., Pomboza-Junez, G., Paderewski, P., & Vela, F. L. G. (2019) · International Conference on Human Computer Interaction (Interacción) · doi:10.1145/3335595.3335636 · Cited by 11
Olsson, A. E., Malešević, N., Björkman, A., & Antfolk, C. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.777329 · Cited by 11
A biomechanical model for the development of myoelectric hand prosthesis control systems
Peerdeman, B., Boerey, D., Kallenbergy, L., Stramigioli, S., & Misra, S. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626085 · Cited by 11
Ahmadi, F., Ribeiro, M. A., & Halaki, M. (2014) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2014.6981639 · Cited by 11
Fu, J., Xiong, L., Song, X., Yan, Z., & Xie, Y. (2017) · IEEE/SICE International Symposium on System Integration (SII) · doi:10.1109/sii.2017.8279278 · Cited by 11
Hand-movement Prediction from EMG with LSTM-Recurrent Neural Networks
García-Vellisca, M. A., Matran‐Fernandez, A., Poli, R., & Citi, L. (2021) · Global Medical Engineering Physics Exchanges/Pan American Health Care Exchanges (GMEPE/PAHCE) · doi:10.1109/gmepe/pahce50215.2021.9434840 · Cited by 10
Fusion of fuzzy logic and PD control for a five-fingered smart prosthetic hand
Chen, C.-H., & Naidu, D. S. (2011) · IEEE International Conference on Fuzzy Systems (FUZZ-IEEE) · doi:10.1109/fuzzy.2011.6007645 · Cited by 10
Surgical and non-surgical prosthetic hands control: A review
Zaini, M. H. M., & Ahmad, S. A. (2011) · IEEE Symposium on Industrial Electronics & Applications (ISIEA) · doi:10.1109/isiea.2011.6108792 · Cited by 10
Baseline Adaptive Wavelet Thresholding Technique for sEMG Denoising
Bartolomeo, L. D., Zecca, M., Sessa, S., Lin, Z., Mukaeda, Y., Ishii, H., Takanishi, A., Pham, T. D., Zhou, X., Tanaka, H., et al. (2011) · AIP conference proceedings · doi:10.1063/1.3596644 · Cited by 10
Self-citationAdaptive common average filtering for myocontrol applications
Rehbaum, H., & Farina, D. (2014) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-014-1215-1 · Cited by 10
A Prosthetic Hand Control Based on Nonstationary EMG at the Start of Movement
Tsukamoto, M., Kondo, T., & Ito, K. (2007) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2007.p0381 · Cited by 10
Li, J., Zhou, Y., Zheng, Y., & Li, G. (2015) · Ultrasonics · doi:10.1016/j.ultras.2015.03.009 · Cited by 10
EMG-force estimation for multiple fingers
Liu, P., Brown, D. R., Clancy, E. A., Martel, F., & Rancourt, D. (2013) · IEEE Signal Processing in Medicine and Biology Symposium · doi:10.1109/spmb.2013.6736772 · Cited by 10
Kreipe, S., Helbig, T., Witte, H., Schumann, N.-P., & Anders, C. (2024) · Bioengineering · doi:10.3390/bioengineering11020119 · Cited by 9
Neuro-motor controlled wearable augmentations: current research and emerging trends
Alsuradi, H., Hong, J., Mazi, H., & Eid, M. A. (2024) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2024.1443010 · Cited by 9
Dunai, L., Verdú, I. S., Țurcanu, D., & Bostan, V. (2025) · Technologies · doi:10.3390/technologies13010021 · Cited by 10
Lin, L., Dai, Y., Zhang, G., Ge, Y., Mayet, A. M., Pan, X., Yang, G., & Lin, M. (2025) · Results in Engineering · doi:10.1016/j.rineng.2025.106602 · Cited by 9
Han, S., Chu, J., Kim, H., Choi, K., Park, J. W., & Youn, I. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2490739 · Cited by 9
Precise Control Method on Prosthetic Hand Using sEMG Signals
Orban, M., Zhang, X., Lu, Z., Marcal, A., Emad, A., & Masengo, G. (2020) · IEEE International Conference on Cyber Technology in Automation, Control, and Intelligent Systems · doi:10.1109/cyber50695.2020.9279179 · Cited by 9
Hand movement classification using transient state analysis of surface multichannel EMG signal
Mobarak, M. P., Muñoz, R., Gutiérrez, J. M., & Louis-Dorr, V. (2014) · Pan American Health Care Exchanges · doi:10.1109/pahce.2014.6849622 · Cited by 9
Grasp specific and user friendly interface design for myoelectric hand prostheses
Mohammadi, A., Lavranos, J., Howe, R. D., Choong, P., & Oetomo, D. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009480 · Cited by 9
A Novel Underactuated Soft Humanoid Hand For Hand Sign Language
Salem, M. E. M., Wen, R., Xu, M. H., Yan, L., Ma, X., & Wang, Q. (2019) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2019.8827021 · Cited by 9
Feature Extraction Using Wavelet Scattering Transform Coefficients for EMG Pattern Classification
Taee, A. A. A., Khushaba, R. N., Zia, T. A., & Al-Jumaily, A. A. (2022) · Lecture notes in computer science · doi:10.1007/978-3-030-97546-3_15 · Cited by 11
Comparison of myocontrol and force control based on fitts’ law model
Park, J., Kim, H., Chung, W., & Park, S. (2011) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-011-0029-4 · Cited by 9
Motion recognition of the bilateral upper-limb rehabilitation using sEMG based on ensemble EMD
Song, X., Guo, S., Gao, B., & Wang, Z. (2014) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2014.6885945 · Cited by 9
The weight load inconsistency effect on voluntary movement recognition of essential tremor patient
Seki, M., Matsumoto, Y., Ando, T., Kobayashi, Y., Iijima, H., Nagaoka, M., & Fujie, M. G. (2011) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2011.6181402 · Cited by 9
Akamatsu, T., Kawashima, N., Tsunekuni, T., Imagawa, K., & Miyasaka, M. (2015) · European Journal of Plastic Surgery · doi:10.1007/s00238-015-1111-4 · Cited by 9
A hybrid adaptive data fusion with linear and nonlinear models for skeletal muscle force estimation
Kumar, P., Potluri, C., Anugolu, M., Sebastian, A., Creelman, J., Urfer, A., Chiu, S., Naidu, D. S., & Schoen, M. P. (2010) · Cairo International Biomedical Engineering Conference · doi:10.1109/cibec.2010.5716075 · Cited by 9
Design Principles of a Light, Wearable Upper Limb Interface for Prosthetics and Teleoperation
Castellini, C. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814659-0.00020-5 · Cited by 9
A Low-Cost Arm Robotic Platform based on Myoelectric Control for Rehabilitation Engineering
Ruiz-Olaya, A. F., Burgos, C. A. Q., & Londono, L. T. (2019) · IEEE Annual Ubiquitous Computing, Electronics & Mobile Communication Conference (UEMCON) · doi:10.1109/uemcon47517.2019.8993080 · Cited by 9
Kwon, S., & Kim, J. (2009) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.2009.5346905 · Cited by 9
Design methods for innovative hand prostheses
Carrozza, M. C., Cappiello, G., Beccai, L., Zaccone, F., Micera, S., & Dario, P. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404209 · Cited by 9
Self-citationToward Natural Limb Function: A New Era in Prosthetic Innovation
Tian, Y., Wallace, D. M., Cederna, P. S., Chestek, C. A., & Kemp, S. W. P. (2025) · Annals of Neurology · doi:10.1002/ana.27287 · Cited by 8
Quinn, K. N., Tian, Y., Budde, R. B., Irazoqui, P. P., TUFFAHA, S. H., & Thakor, N. V. (2023) · Muscle & Nerve · doi:10.1002/mus.28029 · Cited by 8
Classification of the surface EMG signal using RQA based representations
Yuan, C., Zhu, X., Liu, G., & Lei, M. (2008) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2008.4634087 · Cited by 8
Posture recognition of elbow flexion and extension using sEMG signal based on multi-scale entropy
Wang, Z., Guo, S., Gao, B., & Song, X. (2014) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2014.6885857 · Cited by 8
Taee, A. A. A., Khushaba, R. N., Zia, T. A., & Al-Jumaily, A. A. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871473 · Cited by 8
Kurzynski, M. W., & Wołczowski, A. R. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-31196-3_20 · Cited by 8
Scientific models and ethical issues in hybrid bionic systems research
Salvini, P., Datteri, E., Laschi, C., & Dario, P. (2007) · AI & Society · doi:10.1007/s00146-007-0158-6 · Cited by 8
Self-citationFinger joint continuous interpretation based on sEMG signals and muscular model
Pang, M., Guo, S., & Zhang, S. (2013) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2013.6618124 · Cited by 8
Comparison of sonomyography and electromyography of forearm muscles in the guided wrist extension
Guo, J.-Y., Zheng, Y., Huang, Q.-H., Chen, X., & He, J.-F. (2008) · IEEE/EMBS International Summer School on Medical Devices and Biosensors (ISSS-MDBS) · doi:10.1109/issmdbs.2008.4575062 · Cited by 8
Dimensionality Reduction for the Control of Powered Upper Limb Prostheses
Buchenrieder, K. J. (2007) · IEEE International Conference and Workshop on the Engineering of Computer-Based Systems (ECBS) · doi:10.1109/ecbs.2007.32 · Cited by 8
Design of a cost-effective EMG driven bionic leg
Latif, T., Ellahi, C. M., Choudhury, T., & Rabbani, K. S.-E. (2008) · International Conference on Electrical and Computer Engineering (ICECE) · doi:10.1109/icece.2008.4769177 · Cited by 8
Novel wearable EMG sensors based on nanowire technology
Myers, A. C., Du, L., Huang, H., & Zhu, Y. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943928 · Cited by 8
Song, Z., & Zhang, S. (2016) · Sensors · doi:10.3390/s16101739 · Cited by 8
Novel algorithm for conventional myocontrol of upper limbs prosthetics
Benchabane, S. I., Saadia, N., & Ramdane-Chérif, A. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101791 · Cited by 8
sEMG based fuzzy control strategy with ANFIS path planning for prosthetic hand
Potluri, C., Kumar, P., Anugolu, M., Chiu, S. C., Urfer, A., Schoen, M. P., & Naidu, D. S. (2010) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2010.5627782 · Cited by 8
Comparative Analysis of Classifiers for EMG Signals
Saeed, B. A., Gilani, S. O., Rehman, M. Z. U., Jamil, M., Waris, A., & Khan, M. N. (2019) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2019.8861835 · Cited by 8
New advances in EMG control methods of anthropomorphic prosthetic hand
Wang, Y., Liu, H., Leng, D., Gao, W., Cai, M., Xu, W., Zhang, X. D., & Shi, Y. (2017) · Science China Technological Sciences · doi:10.1007/s11431-017-9159-3 · Cited by 8
Grzejszczak, T., Roksela, A., Poświata, A., Siemianowicz, A., Kiełboń, A., & Mikulski, M. (2024) · Sensors · doi:10.3390/s24061964 · Cited by 7
Development of two degree of freedom (DoF) bionic hand for below elbow amputee
Srinivasa, P. L., Nagananda, S. N., Kadambi, G. R., Hariharan, R., Shankpal, P., & Shankapal, S. R. (2013) · IEEE International Conference on Electronics, Computing and Communication Technologies (CONECCT) · doi:10.1109/conecct.2013.6469296 · Cited by 7
Alotaibi, N. D., Jahanshahi, H., Yao, Q., Mou, J., & Bekiros, S. D. (2023) · Mathematics · doi:10.3390/math11184004 · Cited by 7
Movements classification system for transhumeral amputees using myoelectric signals
Hurtado, É. F. A., Varón, L. A. B., Sarria-Paja, M., Carmona, J. A. A., Durán, J. C. S., & Mayor, J. J. V. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106776 · Cited by 7
Study of the SEMG probability distribution of the paretic tibialis anterior muscle
Cherniz, A. S., Bonell, C. E., & Tabernig, C. B. (2007) · Journal of Physics Conference Series · doi:10.1088/1742-6596/90/1/012054 · Cited by 7
Fontana, J. M., & Chiu, A. W. L. (2013) · Assistive Technology · doi:10.1080/10400435.2013.827138 · Cited by 7
Development of a Parent Wireless Assistive Interface for Myoelectric Prosthetic Hands for Children
Hiyoshi, Y., Murai, Y., Yabuki, Y., TAKAHANA, K., Morishita, S., Jiang, Y., Togo, S., Takayama, S., & Yokoi, H. (2018) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2018.00048 · Cited by 7
The Study of Time Domain Features of EMG Signals for Detecting Driver’s Drowsiness
Naim, F., Mustafa, M., Sulaiman, N., & Rahman, N. A. A. (2021) · Lecture notes in electrical engineering · doi:10.1007/978-981-33-4597-3_39 · Cited by 7
Improved swarm-wavelet based extreme learning machine for myoelectric pattern recognition
Budiarsa, A. P. B., Leu, J., Yuen, K. K. F., & Sigalingging, X. K. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.103737 · Cited by 7
Kurzynski, M. W., Krysmann, M., Trajdos, P., & Wołczowski, A. R. (2014) · IEEE International Conference on Tools with Artificial Intelligence (ICTAI) · doi:10.1109/ictai.2014.98 · Cited by 7
Song, Z., Guo, S., Pang, M., & Zhang, S. (2012) · International Symposium on Micro-NanoMechatronics and Human Science · doi:10.1109/mhs.2012.6492483 · Cited by 7
Tkach, D. C., Young, A. J., Smith, L. H., & Hargrove, L. J. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346922 · Cited by 7
Rosa, I. D. G., Garcia, M. A. C., & de Souza, M. N. (2013) · Archives of Control Sciences · doi:10.2478/acsc-2013-0023 · Cited by 7
Recognition of hand motions via surface EMG signal with rough entropy
Zhong, J., Shi, J., Cai, Y., & Zhang, Q. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091018 · Cited by 7
A Fuzzy PID Control Method for the Grasping Force of an Underactuated Prosthetic Hand
Li, Q. M., & Lv, Y. P. (2014) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.551.514 · Cited by 7
A novel feature reduction method for real-time EMG pattern recognition system
Yang, P., Xing, K., Huang, J., & Wang, Y. (2013) · Chinese Control and Decision Conference (CCDC) · doi:10.1109/ccdc.2013.6561165 · Cited by 7
Bond graph modelling of a customized anthropomorphic prosthetic hand with LQR control synthesis
Abbasi, S. H., & Mahmood, A. (2017) · International Multi-Topic Conference · doi:10.1109/inmic.2017.8289466 · Cited by 7
Grabczyński, A., Szklanny, K., & Wrzeciono, P. (2019) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/s13246-019-00770-5 · Cited by 7
Gait Recognition Based on EMG Information with Multiple Features
Cao, Y., Gao, F., Yu, L., & She, Q. (2018) · IFIP advances in information and communication technology · doi:10.1007/978-3-030-00828-4_41 · Cited by 7
2D Subspaces for Sparse Control of High-DOF Robots
Jenkins, O. C. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259857 · Cited by 7
Low-cost assistive device for hand gesture recognition using sEMG (Erratum)
Cymbalak, D., Kardoš, S., Fecil'ak, P., Jakab, F., Mak, A., & Kainz, O. (2016) · International Workshop on Pattern Recognition (IWPR) · doi:10.1117/12.2243167 · Cited by 7
Uncovering attempted movements of the paralyzed upper limb after stroke through EEG and EMG
López‐Larraz, E., Sarasola-Sanz, A., Birbaumer, N., & Ramos‐Murguialday, A. (2025) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-025-01687-9 · Cited by 8
Design of a myoelectric prosthetic training and assessment system
Scoufield, J. A., & Schreiner, S. R. (2004) · IEEE Annual Northeast Bioengineering Conference (NEBEC) · doi:10.1109/nebc.2004.1300064 · Cited by 6
Champaty, B., Biswal, B., Pal, K., & Tibarewala, D. N. (2014) · International Conference on Automation, Control, Energy and Systems (ACES) · doi:10.1109/aces.2014.6808012 · Cited by 6
Gupta, R., & Kulshreshtha, A. (2016) · International Conference on Communication, Control and Intelligent Systems (CCIS) · doi:10.1109/ccintels.2016.7878199 · Cited by 6
Online Fault Detection Approach of Unpredictable Inputs: Application to Handwriting System
Chihi, I., & Benrejeb, M. (2018) · Complexity · doi:10.1155/2018/9789060 · Cited by 6
Guerrero, J. A., & Macías‐Díaz, J. E. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101699 · Cited by 6
Hameed, H. K., Hasan, W. Z. W., Shafie, S. B., Ahmad, S. A., Jaafar, H., & Mat, L. N. I. (2020) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2020.1753838 · Cited by 6
Do Cost Functions for Tracking Error Generalize across Tasks with Different Noise Levels?
Sensinger, J. W., Aleman‐Zapata, A., & Englehart, K. B. (2015) · PLoS ONE · doi:10.1371/journal.pone.0136251 · Cited by 6
EMG Classification for Application in Hierarchical FES System for Lower Limb Movement Control
Zhang, D., Wang, Y., Chen, X., & Xu, F. Y. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-25486-4_17 · Cited by 6
Analysis of myoelectric signals using a Field Programmable SoC
Borbély, B. J., Kineses, Z., Vorohazi, Z., Nagy, Z., & Szolgay, P. (2013) · European Conference on Circuit Theory and Design · doi:10.1109/ecctd.2013.6662255 · Cited by 6
A biomimetic similarity index for prosthetic hands
Kakoty, N. M., & Hazarika, S. M. (2013) · doi:10.1109/cirat.2013.6613820 · Cited by 6
Fimbel, E. J., & Arguin, M. (2007) · PLoS ONE · doi:10.1371/journal.pone.0001219 · Cited by 6
Design and implementation of a special purpose embedded system for neural machine interface
Zhang, X., Huang, H., & Yang, Q. (2010) · IEEE International Conference on Computer Design: VLSI in Computers and Processors (ICCD) · doi:10.1109/iccd.2010.5647801 · Cited by 6
Metadata
- Authors
- Zecca, M., Micera, S., Carrozza, M. C., & Dario, P.
- Affiliations
- Scuola Superiore Sant'Anna (IT)
- Venue
- Critical Reviews? in Biomedical Engineering
- Publisher
- Begell House
- Published
- 2002
- Volume
- 30
- Issue
- 4-6
- Pages
- 459-485
- ISSN
- 0278-940X (ISSN-L)
- OpenAlex
- W4242470988
- Cited by
- 606
- References
- 0
- Citations by year
- 2026: 7 · 2025: 19 · 2024: 16 · 2023: 23 · 2022: 19 · 2021: 18 · 2020: 26 · 2019: 37 · 2018: 37 · 2017: 41 · 2016: 31 · 2015: 31 · 2014: 57 · 2013: 44 · 2012: 38
- FWCI
- 3.87
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Critical Reviews in Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- BOA (University of Milano-Bicocca) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- prosthetic hand, myoelectric control, EMG signal processing, degrees of freedom, grasping, sensory feedback
- MeSH terms
- Algorithms, Artificial Limbs, Electromyography, Feedback, Hand, Hand Injuries, Humans, Pattern Recognition, Automated, Prosthesis Design, Quality Control, Signal Processing, Computer-Assisted, Neural Networks, Computer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review