Cited by 22Neuroendocrine regulation and behaviorNeuropeptides and Animal PhysiologyPregnancy-related medical research

THE DEVELOPMENT OF A RADIOIMMUNOASSAY FOR OXYTOCIN: SENSITIVITY OF THE ASSAY IN AQUEOUS BUFFER SOLUTION, SPECIFICITY AND THE DISSOCIATION OF IMMUNOLOGICAL AND BIOLOGICAL ACTIVITY

CHARD, T., FORSLING, M. L., JAMES, M. A. R., KITAU, M. J., LANDON, J.·1970·Journal of Endocrinology

Abstract

SUMMARY: A radioimmunoassay for oxytocin in aqueous solution is described, with a sensitivity comparable with the best current bioassays. It is highly specific; arginine-vasopressin and lysine-vasopressin interfere only at 1000-fold greater concentration, while bradykinin, histamine, acetycholine and many other substances, which interfere with some bioassays, have no effect. In certain circumstances, there is a dissociation between loss of biological and immunological activity. Thus reducing agents had no effect on immunological activity, in contrast to their effect on biological activity. In late pregnancy plasma, the biological activity of oxytocin is destroyed more rapidly than the immunological activity. Radioimmunoassays have considerable advantages over bioassays both in convenience and specificity. However, bioassays should be employed for reference purposes because of the dissociation between biological and immunological activity that may occur.

Integrity signals

Registry

Crossref · 10.1677/joe.0.0460533

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • By the 1980s, many laboratories had generated radioimmunoassays for oxytocin using independently produced antibodies, and most but not all required extraction.

    “By the 1980s, many laboratories had generated radioimmunoassays for oxytocin, using independently produced antibodies 58, 72, 73, 74, 94, 95, 96, 97, 98] and most, but not all 99, 100, required extraction.”
  • The human posterior pituitary contains approximately 21 μg of oxytocin, whereas that of the rat contains 0.5-1 μg.

    “the human posterior pituitary contains approximately 21 μg of oxytocin 72, 73, 74, whereas that of the rat contains 0.5–1 μg.”

Cited by

Sorted by citations

Authors
CHARD, T., FORSLING, M. L., JAMES, M. A. R., KITAU, M. J., & LANDON, J.
Venue
Journal of Endocrinology
Published
1970-04-01
Volume
46
Issue
4
Pages
533-542
ISSN
  • 0022-0795 (ISSN-L)
  • 1479-6805
OpenAlex
W2034287189
Cited by
22
References
0
Citations by year
2016: 1
FWCI
8.83
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Endocrinology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Social Sciences › Psychology › Social Psychology › Neuroendocrine regulation and behavior
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuropeptides and Animal Physiology
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Pregnancy-related medical research
Keywords
oxytocin, radioimmunoassay, assay sensitivity, assay specificity, vasopressin, lysine vasopressin, bradykinin, histamine, acetylcholine, reducing agents, bioassay comparison
MeSH terms
Acetylcholine, Animals, Biological Assay, Bradykinin, Buffers, Female, Histamine, Iodine Isotopes, Mammary Glands, Animal, Methods, Oxidation-Reduction, Oxytocin, Pregnancy, Radioimmunoassay, Vasopressins, Water, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review