Walking after incomplete spinal cord injury using an implanted FES system: A case report
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Implanted functional electrical stimulation (FES) systems for walking are experimentally available to individuals with incomplete spinal cord injury (SCI); however, data on short-term therapeutic and functional outcomes are limited. The goal of this study was to quantify therapeutic and functional effects of an implanted FES system for walking after incomplete cervical SCI. After robotic-assisted treadmill training and overground gait training maximized his voluntary function, an individual with incomplete SCI (American Spinal Injury Association grade C, cervical level 6-7) who could stand volitionally but not step was surgically implanted with an 8-channel receiver stimulator and intramuscular electrodes. Electrodes were implanted bilaterally, recruiting iliopsoas, vastus intermedius and lateralis, tensor fasciae latae, tibialis anterior, and peroneus longus muscles. Twelve weeks of training followed limited activity post-surgery. Customized stimulation patterns addressed gait deficits via an external control unit. The system was well-tolerated and reliable. After the 12-week training, maximal walking distance increased (from 14 m to 309 m), maximal walking speed was 10 times greater (from 0.02 m/s to 0.20 m/s), and physiological cost index was 5 times less (from 44.4 beats/m to 8.6 beats/m). Voluntary locomotor function was unchanged. The implanted FES system was well-tolerated, reliable, and supplemented function, allowing the participant limited community ambulation. Physiological effort decreased and maximal walking distance increased dramatically over 12 weeks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216 · cited 1×
“Temporal and spatial gait data were collected at 60 Hz with the modified Helen Hayes Marker set [40–41] used to derive gait parameters.”
MethodA gait analysis data collection and reduction technique
Davis, R. B., Õunpuu, S., Tyburski, D., & Gage, J. R. (1991) · Human Movement Science · doi:10.1016/0167-9457(91)90046-z · Cited by 3,086 · cited 1×
“Temporal and spatial gait data were collected at 60 Hz with the modified Helen Hayes Marker set [40–41] used to derive gait parameters.”
MethodClassification of Walking Handicap in the Stroke Population
Perry, J., Garrett, M., Gronley, J. K., & Mulroy, S. J. (1995) · Stroke · doi:10.1161/01.str.26.6.982 · Cited by 1,560
Clinical Gait Assessment in the Neurologically Impaired
Holden, M. K., Gill, K. M., Magliozzi, M. R., Nathan, J., & Piehl-Baker, L. (1984) · Physical Therapy · doi:10.1093/ptj/64.1.35 · Cited by 1,499
Peckham, P. H., Keith, M. W., Kilgore, K. L., Grill, J. H., Wuolle, K. S., Thrope, G. B., Gorman, P., Hobby, J., Mulcahey, M. J., Carroll, S., et al. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.25910 · Cited by 319
A review of portable FES-based neural orthoses for the correction of drop foot
Lyons, G. M., Sinkjaer, T., Burridge, J. H., & Wilcox, D. J. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806832 · Cited by 277 · cited 2×
“Although surface and percutaneous FES technologies have been developed and used by many laboratories worldwide for decades [11,14,21– 22,25], we present the deployment of implantable technology from our center that may surmount the challenges of ambulation after incomplete paralysis.”
BackgroundSmith, B., Tang, Z., Johnson, M. W., Pourmehdi, S., Gazdik, M. M., Buckett, J. R., & Peckham, P. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664202 · Cited by 270
An Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*
KILGORE, K. L., PECKHAM, P. H., KEITH, M. W., THROPE, G. B., WUOLLE, K. S., BRYDEN, A. M., & HART, R. L. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00008 · Cited by 192 · cited 1×
“Fully implanted pacemaker-like systems, on the other hand, offer numerous advantages over surface and percutaneous stimulation for long-term clinical use, including improved convenience, cosmesis, reliability, and repeatability [26].”
Background
Cited by
“Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves”
Christie, B. P., Freeberg, M., Memberg, W. D., Pinault, G. J. C., Hoyen, H. A., Tyler, D. J., & Triolo, R. J. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0285-3 · Cited by 97
Self-citationElectrical Stimulation and Motor Recovery
Young, W. (2015) · Cell Transplantation · doi:10.3727/096368915x686904 · Cited by 76
The design of and chronic tissue response to a composite nerve electrode with patterned stiffness
Freeberg, M. J., Stone, M. A., Triolo, R. J., & Tyler, D. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6632 · Cited by 54
Self-citation
Metadata
- Authors
- Hardin, E., Kobetic, R., Murray, L., Corado-Ahmed, M., Pinault, G., Sakai, J., Nogan Bailey, S., Ho, C., & Triolo, R. J.
- Venue
- The Journal of Rehabilitation Research and Development
- Published
- 2007
- Volume
- 44
- Issue
- 3
- Pages
- 333
- ISSN
- 0742-3241 (ISSN-L)
- 0748-7711
- OpenAlex
- W2155698835
- Cited by
- 90
- References
- 8
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Walking after incomplete spinal cord injury using an implanted FES system: A case report. https://app.cochat.ai/papers/10.1682/jrrd.2007.03.0333
- The paper
- Hardin, E., Kobetic, R., Murray, L., Corado-Ahmed, M., Pinault, G., Sakai, J., Nogan Bailey, S., Ho, C., & Triolo, R. J. (2007). Walking after incomplete spinal cord injury using an implanted FES system: A case report. The Journal of Rehabilitation Research and Development. https://doi.org/10.1682/jrrd.2007.03.0333
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.